Abstract The research focuses exclusively on a simplified non-destructive testing procedure for first estimating structural integrity of monuments in constrained frame determined by emergency switchboard, need of rapidity, absence of economic support and complexity of the site and environment. The survey was inspired by the experimental outcomes obtained through easy-bring devices applied on a very old Buddhist Temple in Bagan (Myanmar) – whose area is UNESCO's site – built in the XII century. The ductile devices used for the investigation are the rebound hammer, the endoscopy and the ultra-sonic test. The procedure has been applied locally in the more significant masonry bearing parts of the temple. Particularly attention has been paid on the evaluation of the compression strength of brick and on the brick-mortar joints efficiency. The survey's approach is rapid, strictly in the frame of a preliminary and limited characterization, but significant for a first understanding of the masonry's integrity in absence of dedicated and elevated resources. The study outlines the reliability/limitations of the simplified and poor investigation's procedure in constrained boundary conditions, which is a very common situation in the anamnesis and diagnosis phases of monuments before restoration.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Health Monitoring Techniques · Concrete Corrosion and Durability · Structural Engineering and Vibration Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (12)
Show source-provided references
1. S. Russo, “On the monitoring of historic Anime Sante church damaged by earthquake in L’Aquila”. Structural control and health monitoring, ISSN: 1545-2263, doi: 10.1002/stc.1531; 2012.10.1002/stc.1531 ↗
2. Non-destrcutive defect localization and sizing in concrete columns and masonry pillar from impact-echo testing
3. Pascale · 2005
4. S. Russo, Integrated assessment of monumental structure through ambient vibration and ND tests: the case of Rialto Bridge. J Cult Herit. doi:10.1016/j.culher.2016.01.008.10.1016/j.culher.2016.01.008 ↗
5. Rilem TC 177-MDT workshop: on site control and non destructive evaluation of masonry structures10.1617/13913 ↗
6. J.L. Noland, R.H. Atkinson, J.C. Baur, An investigation into methods of non-destructive evaluation of masonry structures, Report National Science Foundation, National Technical information service report N°PB 82218074, Springfield, Virginia, 1982.
7. Investigation procedures for the diagnosis of historic masonries10.1016/S0950-0618(00)00018-0 ↗
8. Sonic investigation of shear failed reinforced brick masonry
9. Yarmola, J.C., Conservation of historic brick masonry in Bagan, United Nations development program, UNPD/BUR/78/023, Technical Report, Paris 1987.
10. Report IZIIS 83-30/1. Method for repair and strengthening the national monuments in Bagan, Burma. Vol. 1, Institute of earthquake engineering and engineering seismology, University ‘Kiril and Metodij, Skopje, 1983.
11. ASTM C805, Standard test method for rebound number of hardened concrete.
12. Chopra · 2007