journal article·2018-06Open access

State-of-the-art on methods for reducing rising damp in masonry

Elisa Franzoni

Abstract

Abstract Several materials and technologies have been proposed over last century to fight the capillary rise of water from ground in historic masonry buildings. These methods involve different operational principles and different strategies to cope with rising damp, which is one of the most critical problems in the conservation of architectural heritage. However, despite the extensive use of these technologies in historic buildings, the data about their actual effectiveness in the field are still quite limited and the reasons for their success or failure in real masonries have not been fully elucidated yet. This paper provides an overview of the technologies for the removal of rising damp and a state-of-the-art on the results so far obtained by research, both in laboratory and on-site.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Building materials and conservation · Conservation Techniques and Studies · Masonry and Concrete Structural Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (68)

Show source-provided references
1. Rising damp removal from historical masonries: a still open challenge10.1016/j.conbuildmat.2013.12.054 ↗
2. An operative protocol for reliable measurements of moisture in porous materials of ancient buildings10.1016/j.buildenv.2005.05.023 ↗
3. Suction of groundwater10.1179/sic.1971.016 ↗
4. Water movement in porous building materials–VIII, effects of evaporative drying on height of capillary rise equilibrium in walls10.1016/0360-1323(86)90030-2 ↗
5. Challenging transient flooding effects on dampness in brick masonry in Venice by a new technique: the narthex in St. Marco Basilica
6. Zhang Z. A review of rising damp in masonry buildings. Advanced Polymer and Composite Research Group. Department of Mechanical and Design Engineering, University of Portsmouth, Anglesea Building, Portsmouth, Hampshire (http://www.wykamol.com/images/pictures/damproofing/lectros/a-review-of-rising-damp-in-masonry-buildings.pdf) (web site access date April 2, 2018).
7. The treatment of rising damp10.1080/00038628.1973.9697186 ↗
8. Salt damage and rising damp treatment in building structures10.1155/2016/1280894 ↗
9. Building pathology and rehabilitation techniques-a rising damp treatment catalogue10.4028/www.scientific.net/DDF.365.291 ↗
10. European project Emerisda (‘Effectiveness of Methods against Rising Damp in Buildings’), www.emerisda.eu (web site access date April 2, 2018).
11. Clay barriers for protecting historic buildings from ground moisture intrusion10.1186/s40494-017-0144-3 ↗
12. Møller · 2011 · 765
13. Treatment of rising damp and salt decay: the historic masonry buildings of Adelaide, South Australia10.1617/s11527-008-9427-1 ↗
14. Thomas · 1992
15. Trotman · 2007
16. Evaluation of applied remediation works on historical masonry wall exposed to long-term deterioration
17. Treatment of rising damp in historical buildings: wall base ventilation10.1016/j.buildenv.2005.07.034 ↗
18. Underground air duct to control rising moisture in historic buildings: improved design and its drying efficiency10.14311/AP.2017.57.0331 ↗
19. Air channel function for solving moisture problems in buildings10.1016/j.proeng.2017.05.303 ↗
20. Characterization of a hygro-regulated Wall Base Ventilation System for treatment of rising damp in historical buildings
21. Wall base ventilation system to treat rising damp: the influence of the size of the channels
22. Design of the ventilated air channel to resolve moisture problems in the historical church10.1016/j.egypro.2015.11.148 ↗
23. Treatment of rising damp in historic buildings: experimental campaign of wall base ventilation and interface effect analysis10.1016/j.culher.2016.02.012 ↗
24. Wall-base ventilation system to control rising damp: a case study of Vilar de Frades historical church in Portugal10.1080/15583058.2013.878414 ↗
25. Vogeley · 1985 · 113
26. An evaluation of methods of treating rising damp
27. Sodium chloride crystallization in a “salt transporting” restoration plaster10.1016/j.cemconres.2006.03.027 ↗
28. Droll · 1995
29. Aspects of salt and moisture transport in restoration plasters and renders
30. Salt transport and storage parameters of renovation plasters and their possible effects on restored buildings’ walls10.1016/j.conbuildmat.2010.09.034 ↗
31. The behaviour of water-repellent mortars with regards to salt crystallization: from mortar specimens to masonry/render systems10.1617/s11527-016-0891-8 ↗
32. Plasters and renders for salt laden substrates10.1016/j.conbuildmat.2008.09.009 ↗
33. Evaluation of compatibility and durability of a hydraulic lime-based plaster applied on brick wall masonry of historical buildings affected by rising damp phenomena10.1016/S1296-2074(02)01158-5 ↗
34. Investigation on the behaviour of a restoration plaster applied on heavy salt loaded masonry10.1016/j.conbuildmat.2005.02.010 ↗
35. The development of MDDS-COMPASS
36. Efficiency assessment of posterior waterproofing systems of renovated porous limestone masonry work
37. Effect of coatings on moisture and salt transfer phenomena of plasters10.1016/j.conbuildmat.2013.06.050 ↗
38. Substitution ventilated render systems for historic masonry: Salt crystallization tests evaluation10.1016/j.conbuildmat.2015.10.130 ↗
39. Modern solutions to eliminate capillarity moisture from brick walls–Comer method, Institutul Politehnic din Iasi
40. Building waterproofing remediation applying the “total cut” method. Facta Universitatis
41. Masonry wallettes with damp-proof course membrane subjected to cyclic shear: an experimental study10.1016/j.conbuildmat.2010.04.046 ↗
42. Masonry elements with damp-proof course membrane: assessment of shear strength parameters10.1016/j.conbuildmat.2012.04.033 ↗
43. Injection methods for retrofitting of moisture damaged constructions. In: Structural Studies, Repairs and Maintenance of Historical Buildings
44. Long-term performance of chemical damp-proof courses: twelve years of laboratory testing10.1016/j.buildenv.2005.04.017 ↗
45. Injection systems for damp-proofing10.1016/0360-1323(77)90017-8 ↗
46. Recovery of rising-damp damaged masonry: experimental comparison between ‘slow diffusion’ and ‘under pressure’ procedures for waterproofing agents
47. Treatment of rising damp in wet conditions with new hydrophobic pore filling resins
48. Method for assessing liquids for the remedial treatment of rising damp
49. Evaluation of spreading and effectiveness of injection products against rising damp in mortar/brick combinations10.1016/j.proche.2013.03.019 ↗
50. A proposal for test procedure for injection products against rising damp
51. Chemical injection remedial treatments for rising damp–II. Calculation of injection times10.1016/0360-1323(90)90042-P ↗
52. Treatment of rising damp. A laboratory evaluation method
53. Chemical injection remedial treatments for rising damp–I. The interaction of damp-proofing fluids with porous building materials10.1016/0360-1323(88)90001-7 ↗
54. Treatment of rising damp. Evaluation of six chemical products
55. Determination of water content in brick masonry walls using a dielectric probe10.1080/13556207.2012.10785103 ↗
56. Laboratory models for the assessment of the effectiveness of chemical damp-proofing in masonry: existing methods and some proposals for new fixtures
57. Electro-osmotic stabilization of soils
58. Electroosmotic transport in porous construction materials and dehumidification of masonry10.1016/j.conbuildmat.2007.12.013 ↗
59. Ottosen · 2006
60. Modeling of electrokinetic desalination of bricks10.1016/j.electacta.2012.05.132 ↗
61. Evolution of pore solution chemistry, electro-osmosis and rebar corrosion rate induced by realkalization10.1007/BF02482714 ↗
62. Electrokinetic desalination of sandstones for NaCl removal—Test of different clay poultices at the electrodes10.1016/j.electacta.2012.06.005 ↗
63. Electroosmotic drying of building walls and basements10.3103/S1068375507040114 ↗
64. State-of-the-Art Report of RILEM TC 248-MMB (“moisture measurement in building materials and structures”), accepted, in press.
65. An experimental fixture for continuous monitoring of electrical effects in moist masonry walls10.1016/j.conbuildmat.2010.11.047 ↗
66. Pereira-de-Oliveira · 2016
67. Use of TDR to compare rising damp in three tuff walls made with different mortars10.1061/(ASCE)MT.1943-5533.0001794 ↗
68. TDR-based monitoring of rising damp through the embedding of wire-like sensing elements in building structures10.1016/j.measurement.2016.10.044 ↗