journal article·2002-01

Hydrodynamic function of polyurethane prosthetic heart valves: influences of Young's modulus and leaflet thickness

Gillian M. Bernacca, Bernard O’Connor, David F Williams, David J. Wheatley

Biomaterials· Volume 23· Issue 1
Publisher page

Abstract

The development of flexible polyurethane heart valves has been hindered by material degradation in vivo. Low modulus polyurethane leaflets are regarded as desirable to achieve good hydrodynamic function. However, low modulus materials may suffer high strain accumulation, hence poor durability. Higher modulus materials may improve durability, but may have poor hydrodynamic function. This study examines the hydrodynamic behaviour of biostable polyurethane valves, varying Young's modulus from 5 to 63.6 MPa and mean leaflet thickness from 48-238 microm. Parameters studied included mean pressure gradient, energy losses and regurgitation over 5 equivalent cardiac outputs (3.6, 4.9, 6.4, 8.0 and 9.61 min(-1)) At low cardiac output, modulus was not significantly correlated with any parameter of valve opening. At 9.61 min(-1), modulus significantly influenced mean pressure gradient (p = 0.033). Mean leaflet thickness significantly correlated with mean pressure gradient and energy losses during forward flow at all cardiac outputs (p<0.001). This study demonstrates that, over a wide range of moduli, valve hydrodynamic function is not affected significantly by the material modulus. Leaflet thickness is a highly significant factor. Higher modulus elastomers in a range up to 32.5 MPa may be useful in prosthetic heart valve leaflet manufacture, retaining good hydrodynamic function while potentially extending the lifetime of the valve.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Cardiac Valve Diseases and Treatments · Diabetic Foot Ulcer Assessment and Management · Hydraulic and Pneumatic Systems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. Function of expanded polytetrafluoroethylene laminated trileaflet valves in animals
2. The design, fabrication and evaluation of a tri-leaflet prosthetic heart valve10.1115/1.3138196 ↗
3. Hexsyn trileaflet valve10.1111/j.1525-1594.1982.tb04082.x ↗
4. In vivo experimental assessment of polytetrafluoroethylene trileaflet heart valve prosthesis10.1016/S0022-5223(20)31464-1 ↗
5. New polyurethane trileaflet valves
6. The Helmholtz-Institute-tri-leaflet-polyurethane-heart valve prosthesis
7. Evaluation of explanted polyurethane trileaflet cardiac valve prosthesis10.1016/S0022-5223(19)36257-9 ↗
8. A tricuspid polyurethane heart valve as an alternative to mechanical prostheses or bioprostheses
9. The return of elastomer valves10.1016/0003-4975(89)90658-9 ↗
10. Comparative physical tests on segmented polyurethanes for cardiovascular applications10.1016/0267-6605(91)90010-D ↗
11. A synthetic three-leaflet valve10.3109/03091909209021954 ↗
12. Biomedical applications of polyurethanes10.1177/088532829901400104 ↗
13. Calcification and fatigue failure in a polyurethane heart valve10.1016/0142-9612(95)93255-C ↗
14. In vitro function and durability of a polyurethane heart valve
16. An investigation of the in vivo stability of poly(ether urethaneurea) blood sacs10.1002/(SICI)1097-4636(19990315)44:4<371::AID-JBM2>3.0.CO;2-I ↗
17. Polymer heart valves
19. Polydimethylsiloxane/polyether-mixed macrodiol-based polymethane elastomers10.1016/S0142-9612(99)00271-9 ↗
20. Rhodes NP, Shortland AP, Hunt JA, Doherty PJ, Williams DF. In vivo biostability of polyurethanes purported to be biologically stable. Proceedings of the 25th Annual Meeting of the Society for Biomaterials, Providence, Rhode Island, 1999. p. 62.
21. Polyurethane heart valve durability10.1177/039139889702000606 ↗
22. Gunatillake PA, Meijs GF, McCarthy SJ. Polysiloxane-containing polyurethane elastomeric compositions. International patent application PCT/AU97/00619, 1996.
23. Gunatillake PA, Meijs GF, Adhikari R. Silicon-containing chain extenders. International patent application PCT/AU98/00546, 1998.
24. Gunatillake PA, McCarthy SJ, Meijs GF, Adhikari R. Siloxane-containing polyurethane–urea compositions. Australian provisional patent application PP9917, 1999.
25. Poly(dimethylsiloxane)/poly(hexamethylene oxide) mixed macrodiol based polyurethane elastomers. I. Synthesis and properties10.1002/(SICI)1097-4628(20000628)76:14<2026::AID-APP5>3.0.CO;2-X ↗
26. Wheatley DJ, Fisher J, Williams DF. Heart valve prosthesis. International patent number WO9832400, 1998.
27. A new polyurethane heart valve prosthesis10.1016/0142-9612(95)00242-1 ↗
28. Testing of materials for artificial heart valves10.1002/pi.4980100414 ↗