journal article·2004-02

Bond Strength of Tension Lap Splices in High-Strength Concrete Beams Strengthened with Glass Fiber Reinforced Polymer Wraps

Bilal S. Hamad, Ahmad A. Rteil, Khaled A. Soudki

Publisher page

Abstract

This paper presents the experimental results of the first phase of a study undertaken at the American University of Beirut to examine the effectiveness of fiber reinforced polymer (FRP) wraps to confine steel reinforcement in a tension lap splice region anchored in high-strength reinforced-concrete beams. Seven beam specimens were constructed. The specimens were reinforced on the tension side with three deformed bars spliced at midspan. The splice region was devoid of any transverse reinforcement to allow a full examination of the FRP wrap contribution. Glass fiber reinforced polymer (GFRP) sheets were used. The main test variables were the GFRP configuration in the splice region (one strip, two strips, or a continuous strip), and the number of layers of the GFRP wraps placed around the splice region (one layer or two layers). All GFRP wraps were U-shaped. Except for the epoxy adhesive, no other anchorage mechanism or bonding procedure was applied for the GFRP wraps on the concrete beam. Following the application of the GFRP wraps, the beams were tested in positive bending. The test results demonstrated that GFRP wraps were effective in enhancing the bond strength and ductility of failure mode of the tension lap splices, especially when continuous strips were applied over the splice region.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Professor and Chairman, Dept. of Civil and Environmental Engineering, American Univ. of Beirut, P.O. Box 11-0236, Riad El Solh 1107 2020, Beirut, Lebanon.

Graduate Student, Dept. of Civil Engineering, Univ. of Waterloo, Waterloo ON, Canada.

Associate Professor, Dept. of Civil Engineering, Univ. of Waterloo, Waterloo ON, Canada.

References (13)

Show source-provided references
1. American Concrete Institute (ACI). (1996). “State-of-the-art report on fiber reinforced plastic reinforcement for concrete.” ACI 440R-96 Detroit.
2. American Concrete Institute (ACI). (2002). “Building code requirements for reinforced concrete and commentary.” ACI 318-02/ACI 318R-02 Detroit.
3. Proposed modifications to ACI 318-95: Tension development and lap splice for high strength concrete.
4. Behavior of lap-spliced reinforcing bars embedded in high strength concrete.
5. Bond performance of reinforcing bars embedded in high strength concrete.
6. Craig B. and Soudki K. A. (2002). “Confining effects of CFRP on corroded concrete members.” Proc. 2nd Int. Conf. on Durability of Fiber Reinforced Polymer Composites for Construction CDCC 2002 in press.
7. Development length criteria for conventional and high relative area reinforcing bars.
8. Effect of steel fiber reinforcement on bond strength of tension lap splices in high strength concrete.
9. 10.1617/1378610.1617/13786 ↗
10. Orangun O. C. Jirsa J. O. and Breen J. E. (1977). “The strength of anchored bars: A reevaluation of test data on development length and splices.” ACI Struct. J. March 114–122.
11. Sharaf H. A. and Soudki K. A. (2002). “Strength assessment of reinforced concrete beams with debonded reinforcement and confinement with CFRP wraps.” Proc. CSCE 30th Annual Conf. Canadian Society for Civil Engineering Montréal in press.
12. Soudki K. A. (1997). “Rehabilitation of structures by fibre reinforced plastic laminates.” Trends in structural mechanics Proc. ANS Symp. Univ. of Waterloo Waterloo Ont. Canada 125–134.10.1007/978-94-011-5476-5_13 ↗
13. 10.1061/(ASCE)0899-1561(2003)15:4(358)10.1061/(ASCE)0899-1561(2003)15:4(358) ↗