Physical Properties of Glass Fiber Reinforced Polymer Rebars in Compression
Source abstract
Abstract
Forty-five glass fiber reinforced polymer (GFRP) rebars were tested in compression to determine their ultimate strength and Young’s modulus. The rebars (or C-bars), produced by Marshall Industries Composites, Inc., had an outside diameter of 15 mm (#15 rebar), and unbraced lengths varying from 50 to 380 mm. A compression test method was developed to conduct the experiments. Three failure modes, that are directly related to the unbraced length of the rebar, are identified as crushing, buckling, and combined buckling and crushing. The crushing region represents the failure mode a GFRP rebar would experience when confined in concrete under compression. The experimental results showed that the ultimate compressive strength of the #15 GFRP rebar failing by crushing is approximately 50% of the ultimate tensile strength. Based on a very limited number of tests, in which strain readings were acceptable, Young’s modulus in compression was found to be approximately the same as in tension.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
PhD, SE, Structural Engineer, Palmer Engineering, Winchester, KY 40392-0747.
Professor, Dept. of Civil Engineering, Univ. of Kentucky, 161A Raymond Building, Lexington, KY 40506-0281 (corresponding author).
Professor, Dept. of Civil Engineering, Univ. of Kentucky, 161A Raymond Building, Lexington, KY 40506-0281.
References (3)
Show source-provided references
1. Deitz D. H. Harik I. E. and Gesund H. (1999). “GFRP reinforced decks.” Kentucky Transportation Center Research Report No. KTC-00-1 Univ. of Kentucky Lexington Ky.
2. Kobayashi K. and Fujisaki T. (1995). “Compressive behavior of FRP reinforcement in non-prestressed concrete members.” Non-metallic (FRP) reinforcement for concrete structures E&FN Spon London.