journal article·2012-08

Bond Durability of FRP Bars Embedded in Fiber-Reinforced Concrete

Abdeldjelil Belarbi, Huanzi Wang

Publisher page

Abstract

A research program was initiated to develop a nonferrous reinforcement system for concrete bridge decks using continuous fiber-reinforced polymer (FRP) bars and discrete, randomly distributed polypropylene fibers. This hybrid system may eliminate problems related to corrosion of steel reinforcement while providing requisite strength, stiffness, and desired ductility, which are shortcomings of the FRP reinforcing system in plain concrete. This paper presents the results of a part of this research program [i.e., the long-term bond behaviors of this FRP/fiber-reinforced concrete (FRC) hybrid system]. Bond durability for the FRP/plain concrete system that served as a reference is also reported. Test results indicated that ultimate and design bond strength experienced noticeable degradation when exposed to combined environmental conditioning, including freeze-thaw cycles, high temperature (60°C), and deicing salt solution. Test results showed that bond durability significantly improved owing to the restriction of the concrete crack by the addition of polypropylene fibers. The larger specimens with thicker concrete cover and relatively smaller direct exposed area to the solution of sodium chloride (NaCl) showed better bond durability. Comparing glass FRP specimens with carbon FRP specimens, it was found that bond degradation was tightly correlated to the degradation of FRP bars.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Hugh Roy and Lillie Cranz Cullen Professor and Dept. Chair, Dept. of Civil and Environmental Engineering, Univ. of Houston, Houston, TX 77204-4003 (corresponding author).

Bridge Engineer, AECOM, Oakland, CA 94612.

References (25)

Show source-provided references
1. American Concrete Institute (ACI). (2006). “Guide for the design and construction of concrete reinforced with FRP bars.” ACI 440.1R-06 Farmington Hills MI.
2. American Concrete Institute (ACI). (2008a). “Guide to durable concrete.” ACI 201.2R-08 Farmington Hills MI.
3. American Concrete Institute (ACI). (2008b). “Building code requirements for structural concrete and commentary.” ACI 318-08 Farmington Hills MI.
4. Balazs G. L. and Borosnyoi A. (2001). “Long-term behavior of FRP.” Proc. Int. Workshop Composites in Construction: A Reality ASCE Reston VA.10.1061/40596(264)10 ↗
5. Bank L. C. · Accelerated test methods to determine the long-term behavior of FRP composite structures: Environmental effects · 1995 · 14
6. Bank L. C. · The effect of material degradation on bond properties of fiber reinforced plastic reinforcing bars in concrete · 1998 · 95
7. Ceroni F. · Durability issues of FRP rebars in reinforced concrete members · 2006 · 28
8. Chen Y. · Accelerated aging tests for evaluations of durability performance of FRP reinforcing bars for concrete structures · 2007 · 78
9. Davalos J. F. · Effect of FRP bar degradation on interface bond with high strength concrete · 2008 · 30
10. Ferguson P. M. · Pullout tests on high strength reinforcing bars · 1965 · 62
11. Galati N. · Thermal effects on bond between FRP rebars and concrete · 2006 · 37
12. Gylltoft K. Cederwall K. Elfgren L. and Nilsson L. (1982). “Bond failure in reinforcement concrete under monotonic and cyclic loading: A fracture mechanics approach.” Fatigue of Concrete Structures SP-75 American Concrete Institute Detroit 269–287.
13. Katz A. · Effect of high temperature on bond strength of FRP · 1999 · 3
14. Kim H. Y. · Short-term durability test for GFRP rods under various environmental conditions · 2008 · 83
15. Mashima M. and Iwamoto K. (1993). “Bond characteristics of FRP rod and concrete after freezing and thawing deterioration.” Fiber-Reinforced-Plastic Reinforcement for Concrete Structures—International Symposium SP 138 American Concrete Institute Detroit 51–70.
16. Mathey R. G. · Investigation of bond in beam and pull-out specimens with high-yield-strength deformed bars · 1961 · 57
17. Micelli F. · Durability of FRP rods for concrete structures · 2004 · 18
18. RILEM. (1994). “RC6: Bond test for reinforcing steel. 1. Pull-out test.” RILEM Technical Recommendations for the Testing and Use of Construction Materials 7-II-128 E & FN Spon Oxfordshire UK 102–105.
19. Robert M. · Effect of aging on bond of GFRP bars embedded in concrete · 2010 · 32
20. Schutte C. L. · Environmental durability of glass-fiber composites · 1994 · 13
21. Sekijima K. Otsuka Y. and Konno T. (1999). “Durability of fiber reinforced polymer reinforcement embedded in concrete.” 4th Int. Symp. on Fiber Reinforced Polymer Reinforced Concrete Structures SP-188 American Concrete Institute Farmington Hills MI 501–513.
22. Tannous F. E. · Environmental effects on the mechanical properties of E-Glass FRP rebars · 1998 · 95
23. Uomoto T. and Nishimura T. (1999). “Deterioration of aramid glass and carbon fibers due to alkali acid and water in different temperatures.” 4th Int. Symp. on Fiber Reinforced Polymer for Reinforced Concrete Structures SP-188 American Concrete Institute Farmington Hills MI 515–522.
24. Wang H. · Static and fatigue bond characteristics of FRP rebars embedded in fiber-reinforced concrete · 2010 · 44
25. Wang H. · Ductility characteristics of fiber-reinforced-concrete beams reinforced with FRP rebars · 2011 · 25