Abstract

An approximate analysis method is proposed to determine the blast resistance of fiber-reinforced polymer (FRP)-strengthened masonry walls. The method relates the static to dynamic response by incorporating the strain rate effect on the material strength and a dynamic load factor for the applied peak load. Based on the method, 18 full-scale masonry walls reinforced with three different FRP systems were designed and subjected to field explosions, using charges of 27-ton TNT in one test and 5-ton TNT in the other. For each test, the walls were placed at three different standoff distances and orientations to the blast source. The response of the strengthened walls under blast was monitored by high-speed data acquisition systems. Post-test observations indicated no visible damage, crack, or debonding in any of the walls, thus confirming the effectiveness of the FRP retrofit technique in blast protection. The data presented are valuable for validation of analytical or numerical models.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Response to Dynamic Loads · Structural Behavior of Reinforced Concrete · Transportation Safety and Impact Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Associate Professor, Dept. of Civil Engineering, National Univ. of Singapore, Block E1A, #07-03, 1 Engineering Drive 2, 117576, Singapore (corresponding author).

Senior Bridge Engineer, GHD Pty Ltd., Level 8, 180 Lonsdale St., Melbourne, Australia. E-mail: kabir@alumni.nus.edu.sg

References (19)

Show source-provided references
1. American Concrete Institute (ACI). (2007). “State-of-the-art report on fiber reinforced polymer reinforcement for concrete structures.” ACI440R–07 Detroit.
2. 10.1061/(ASCE)0733-9445(2005)131:8(1186)10.1061/(ASCE)0733-9445(2005)131:8(1186) ↗
3. Biggs J. M. · 1964 · 213
4. Carney P. and Myers J. J. (2005). “Out-of-plane static and blast resistance of unreinforced masonry wall connections strengthened with FRP.” Proc. 7th Int. Symp. on Fiber-Reinforced Polymer Reinforcement for Concrete Structures American Concrete Institute Kansas City Mo. 229–248.
5. 10.1061/(ASCE)0733-9445(2005)131:8(1194)10.1061/(ASCE)0733-9445(2005)131:8(1194) ↗
6. 10.1061/(ASCE)0887-3828(2004)18:2(100)10.1061/(ASCE)0887-3828(2004)18:2(100) ↗
7. Ehsani M. R. · 1995 · 681
8. 10.1016/S0266-3538(98)00007-410.1016/S0266-3538(98)00007-4 ↗
9. 10.1007/978-1-349-14827-1_210.1007/978-1-349-14827-1_2 ↗
10. 10.1061/(ASCE)1090-0268(2007)11:6(601)10.1061/(ASCE)1090-0268(2007)11:6(601) ↗
11. 10.1061/(ASCE)1090-0268(2003)7:2(98)10.1061/(ASCE)1090-0268(2003)7:2(98) ↗
12. Patoary M. K. H. and Tan K. H. (2003). “Blast resistance of prototype in-built masonry walls strengthened with FRP systems.” Proc. 6th Int. Symp. on Fiber-Reinforced Polymer Reinforcement for Concrete Structures K. H. Tan ed. World Scientific Singapore 1189–1198.10.1142/9789812704863_0114 ↗
13. Fiber composites for new and existing structures
14. 10.1016/S0950-0618(97)00054-810.1016/S0950-0618(97)00054-8 ↗
15. 10.1061/(ASCE)1090-0268(2004)8:1(79)10.1061/(ASCE)1090-0268(2004)8:1(79) ↗
16. 10.1061/(ASCE)1090-0268(1998)2:2(96)10.1061/(ASCE)1090-0268(1998)2:2(96) ↗
17. U.S. Department of the Army · 1986
18. U.S. Department of the Army · 1990
19. Volkman D. E. · 1990 · 413