journal article·2012-04

Long-Term Performance of GFRP Tubes Filled with Concrete and Subjected to Salt Solution

Mathieu Robert, Amir Fam

Publisher page

Abstract

This paper presents mechanical, microstructural, and physical characterization of aged glass fiber-reinforced polymer (GFRP) tubes used in the concrete-filled fiber-reinforced polymer (FRP) tube (CFFT) system for bridge columns and marine pile applications, or used hollow as tubular poles or in pipelines. The main objective of the study is to evaluate the durability and predict the long-term behavior of the filament-wound GFRP tubes. CFFTs were exposed to salt solution at 23, 40, and 50°C for 365 days to accelerate the environmental effect. Given the significance of confinement in a CFFT system, the measured hoop tensile strength of the tube before and after exposure was considered the primary indicator of durability performance of the specimens. In addition, Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), and scanning electron microscopy (SEM) were used to characterize the aging effect on GFRP tubes. Test results showed that the GFRP tubes investigated in this study, and exposed to a rather aggressive environment, performed well. The reduction in hoop tensile strength at the end of exposure ranged from 11 to 21%, depending on temperature. Using the Arrhenius theory, the predicted reduction in strength after 100 years at a mean annual temperature of 6°C, representing some northern regions, was estimated at approximately 32%.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Mechanical Behavior of Composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Post doctoral Fellow, Dept. of Civil Engineering, Queen’s Univ., Kingston, Ontario, Canada (corresponding author).

Professor and Canada Research Chair in Innovative and Retrofitted Structures, Dept. of Civil Engineering, Queen’s Univ., Kingston, Ontario, Canada.

References (41)

Show source-provided references
1. Abeysinghe H. · Degradation of crosslinked resins in water and electrolyte solutions · 1982 · 23
2. Apicella A. · Water sorption and mechanical properties of a glass-reinforced polyester resin · 1982 · 13
3. Ashbee K. · Water damage in polyester resins · 1967 · 300
4. Ashbee K. · Water damage in glass fibre/resin composites · 1969 · 312
5. ASTM. (2000). “Standard test methods for density and specific gravity (relative density) of plastics by displacement.” D792 West Conshohocken PA.
6. ASTM. (2003a). “Standard test method for assignment of the glass transition temperature by differential scanning calorimetry.” E1356 West Conshohocken PA.
7. ASTM. (2003b). “Standard test method for compositional analysis by thermogravimetry.” E1132 West Conshohocken PA.
8. ASTM. (2008). “Standard test method for apparent hoop tensile strength of plastic or reinforced plastic pipe by split disk method.” D2290 West Conshohocken PA.
9. ASTM. (2010). “Standard test method for water absorption of plastics.” D570 West Conshohocken PA.
10. Bank L. C. · A model specification for composites for civil engineering structures · 2003 · 17
11. Benmokrane B. · Durability of glass fibre reinforced polymer reinforcing bars in concrete environment · 2002 · 6
12. Bradshaw R. D. · Physical aging in polymers and polymer composites: An analysis and method for time-aging time superposition · 1997 · 37
13. Chen Y. · Durability prediction for GFRP bars using short-term data of accelerated aging tests · 2006 · 10
14. Chen Y. · Accelerated aging tests for evaluation of durability performance of FRP reinforcing bars reinforcing bars for concrete structures · 2007 · 78
15. Coomarasamy A. · Investigation of the durability characteristics of fiber reinforced plastic (FRP) materials in concrete environment · 1999 · 12
16. Cromwell J. R. · Environmental durability of externally bonded FRP materials intended for repair of concrete structures · 2011 · 25
17. Dejke V. · 1999
18. Dejke V. (2001). “Durability of FRP reinforcement in concrete-literature review and experiments.” Tekn. Lic. thesis Depart. of Builiding Materials Chalmers Univ. of Technology Göteborg Sweden.
19. Diamond S. · Effects of two Danish flyashes on alkali contents of pore solutions of cement fly ash pastes · 1981 · 11
20. Erdiller E. S. (2004). “Experimental investigation for mechanical properties of filament wound composites tubes.” M.S. thesis Middle East Technical Univ. Ankara Turkey.
21. Fam A. · 2003
22. Fam A. · Effects of freezing and thawing cycles and sustained loading on compressive strength of precast concrete composite piles · 2008 · 53
23. Fam A. · Precast composite piles for the route 40 bridge in virginia using concrete-filled FRP tubes · 2003 · 48
24. Fam A. · Confinement model for axially loaded concrete confined by circular fiber-reinforced polymer tubes · 2001 · 98
25. Fam A. Z. Schnerch D. and Rizkalla S. H. (2002). “Moisture effect on durability of concrete-filled GFRP tubular piles.” RD-02-05 North Carolina State Univ. Constructed Facilities Laboratories Raleigh NC.
26. Gerritse A. (1998). “Assessment of long term performance of FRP bars in concrete structures.” Proc. Durability of Fiber Reinforced Polymers (FRP) Composites for Construction Sherbrooke Québec Canada 285–297.
27. Karbhari V. M. · Structural characterization of fiber-reinforced composite short- and medium-span bridge systems · 2000 · 7
28. Kshirsagar S. · Environmental aging of fiber-reinforced polymer-wrapped concrete cylinders · 2000 · 97
29. Litherland K. L. · The use of accelerated aging procedures to predict the long term strength of GRC composites · 1981 · 11
30. Miyano Y. · Accelerated testing for long-term durabilty of FRP laminates for marine use · 2005 · 39
31. Murphy K. Zhang S. and Karbhari V. M. (Cohen L. J. Bauer J. L. and Davis W. E.1999). “Effect of concrete based alkaline solutions on short term response of composites.” Proc. 44th Int. SAMPE Symp. and Exhibition eds. Society for the Advancement of Material and Process Engineering Long Beach CA 2222–2230.
32. 10.1002/978047031679510.1002/9780470316795 ↗
33. Porter M. L. Mehus J. Young K. A. O’Neil E. F. and Barnes B. A. (1997). “Aging for fiber reinforcement in concrete.” Proc. of the Third Int. Symp. on Non-Metallic (FRP) Reinforcement for Concrete Structures Japan Concrete Institute Sapporo Japan 2 59–66.
34. Prian L. · Degradation mechanism of fiberreinforced plastics and its implications to prediction of long-term behavior · 1999 · 34
35. Robert M. · Durability of GFRP bars embedded in moist concrete · 2009 · 13
36. Robert M. · Temperature as an accelerating factor for long-term durability testing of FRPS: Should there be any limitations? · 2010 · 14
37. Soles C. L. · Contributions of the nanovoid structure to the moisture absorption properties of epoxy resins · 1998 · 36
38. Soudki K. A. · Freeze-thaw response of CFRP wrapped concrete · 1997 · 19
39. Taylor H. F. W. · A method for predicting alkali ion concentration in cement pore water solutions · 1987 · 1
40. Toutanji H. A. · Effects of freeze-thaw exposure on performance of concrete columns strengthened with advanced composites · 1999 · 96
41. Yuan W. · Buckling analysis of concrete-filled FRP tubes · 2001 · 1