Abstract

The relatively low shear strength of carbon fiber-reinforced polymers (CFRPs) makes it difficult to anchor CFRP tendons. Although many anchorages with CFRP tendons have been developed, few studies have been conducted on composite anchorages with multi-CFRP tendons. In this study, four groups of new mechanical clamping–bonding composite anchorages with multi-CFRP tendons were designed, and the stress of each component of the anchorage was analyzed to reveal the force transmission mechanism of the anchorage. Moreover, the short-term performance of the anchorages was experimentally investigated. The key parameters, including the elastic modulus of the bonding medium, preloading force, cone angle, and bond length, were further analyzed using the finite-element method. The results showed that the composite anchorage reliably anchored multiple CFRP tendons, and the efficiency coefficients of the four anchorages were greater than 0.95. The suggested minimum bond length was approximately 35 times the diameter of the CFRP tendon when anchoring fewer than five tendons. Finally, a sufficient preloading force could effectively reduce the initial slip, whereas increasing the cone angle and elastic modulus could reduce the final slip.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Mechanical stress and fatigue analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Professor, School of Highway, Chang’an Univ., Xi’an 710064, China (corresponding author).

Ph.D. Candidate, School of Highway, Chang’an Univ., Xi’an 710064, China.

Xi’an Highway Research Institute Co., Ltd, Xi’an 710061, China.

School of Architecture & Civil Engineering, Xi’an Univ. of Science & Technology, Xi’an 710054, China.

Associate Professor, School of Highway, Chang’an Univ., Xi’an 710064, China.

References (44)

Show source-provided references
1. Ai, P., P. Feng, H. Liu, P. Zhu, and G. Ding. 2021. “Novel self-anchored CFRP cable system: Concept and anchorage behavior.” Compos. Struct. 263 (2): 113736. https://doi.org/10.1016/j.compstruct.2021.113736.10.1016/j.compstruct.2021.113736 ↗
2. 10.1016/j.compstruct.2005.01.02410.1016/j.compstruct.2005.01.024 ↗
3. 10.1061/(ASCE)CC.1943-5614.000036710.1061/(ASCE)CC.1943-5614.0000367 ↗
4. 10.15554/pcij.03012001.88.10010.15554/pcij.03012001.88.100 ↗
5. 10.1016/S0950-0618(00)00017-910.1016/S0950-0618(00)00017-9 ↗
6. Burgoyne, C. J. 1999. “Advanced composites in civil engineering in Europe.” Struct. Eng. Int. 9 (4): 267–273. https://doi.org/10.2749/101686699780481682.10.2749/101686699780481682 ↗
7. 10.1016/j.conbuildmat.2016.02.20210.1016/j.conbuildmat.2016.02.202 ↗
8. 10.1016/j.compositesb.2015.05.01410.1016/j.compositesb.2015.05.014 ↗
9. Campbell, T. I., N. G. Shrive, K. A. Soudki, A. Al-Mayah, P. J. Keatley, and M. M. Reda. 2011. “Design and evaluation of a wedge-type anchor for fibre reinforced polymer tendon.” Can. J. Civ. Eng. 27 (5): 985–992. https://doi.org/10.1139/l00-048.10.1139/l00-048 ↗
10. Chen, B., S. Li, R. Liu, G. Xie, and N. Zang. 2015. “The static test of the composite anchorage for CFRP tendons and the analysis of the bond stress distribution.” [In Chinese.] Compos. Sci. Eng. 11: 5–8.
11. Chen, M. 2007. Elasticity and plasticity: Thick-walled cylinder subjected to uniform pressure, 106–107. [In Chinese.] Beijing: Science Press.
12. Cheng, D. 2010. Handbook of mechanical design (fifth edition): Common information and formulas. [In Chinese.] Beijing: Chemical Industry Press.
13. 10.1016/j.compstruct.2016.10.04810.1016/j.compstruct.2016.10.048 ↗
14. Fan, H., A. P. Vassilopoulos, and T. Keller. 2017b. “Pull-out behavior of CFRP single-strap ground anchors.” J. Compos. Constr. 21 (3): 04016102. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000760.10.1061/(ASCE)CC.1943-5614.0000760 ↗
15. 10.1016/j.engstruct.2013.09.03810.1016/j.engstruct.2013.09.038 ↗
16. 10.1177/136943321982980610.1177/1369433219829806 ↗
17. 10.3390/polym604112910.3390/polym6041129 ↗
18. Jiang, T., and Z. Fang. 2010. “Experimental investigation on the performance of wedge-bond anchors for CFRP tendons.” [In Chinese.] China Civ. Eng. J. 43 (2): 79–87.
19. Li, S., B. Chen, and G. Xie. 2015. “Finite element analysis of anchorage structure for FRP tendon.” Adv. Mater. Res. 1088: 858–861. https://doi.org/10.4028/www.scientific.net/AMR.1088.858.10.4028/www.scientific.net/AMR.1088.858 ↗
20. 10.3390/polym710150110.3390/polym7101501 ↗
21. Mei, K., X. Li, Y. Li, L. Xing, and S. Sun. 2022. “Study on static performance of large-tonnage anchorage system with CFRP cable.” [In Chinese.] China J. Highway Transp. 35 (2): 76–87. https://doi.org/10.19721/j.cnki.1001-7372.2022.02.006.
22. 10.1016/j.conbuildmat.2015.12.05910.1016/j.conbuildmat.2015.12.059 ↗
23. 10.1016/j.compstruct.2018.05.15310.1016/j.compstruct.2018.05.153 ↗
24. Mei, K., Y. Sun, S. Sun, X. Ren, and J. Zhao. 2020. “Experimental investigation on the mechanical properties of a novel anchorage for carbon fiber reinforced polymer (CFRP) tendon.” Compos. Struct. 234: 11704. https://doi.org/10.1016/j.compstruct.2019.111704.
25. 10.1007/s13369-012-0185-610.1007/s13369-012-0185-6 ↗
26. Puigvert, F., A. D. Crocombe, and L. Gil. 2014. “Static analysis of adhesively bonded anchorages for CFRP tendons.” Constr. Build. Mater. 14: 206–215. https://doi.org/10.1016/j.conbuildmat.2014.02.072.10.1016/j.conbuildmat.2014.02.072 ↗
27. SAC (Standardization Administration of the P.R.C.). 2015. Anchorage, grip and coupler for prestressing tendons. GB/T 14370-2015. Beijing: SAC.
28. 10.1016/j.conbuildmat.2020.12000410.1016/j.conbuildmat.2020.120004 ↗
29. 10.1016/j.conbuildmat.2010.02.00610.1016/j.conbuildmat.2010.02.006 ↗
30. 10.1139/cjce-25-1-11310.1139/cjce-25-1-113 ↗
31. 10.1002/bate.20071002810.1002/bate.200710028 ↗
32. 10.1016/j.conbuildmat.2011.11.04910.1016/j.conbuildmat.2011.11.049 ↗
33. Shi, J., P. Xu, Z. Wu, and X. Wang. 2015. “A novel anchor method for multi-tendon FRP cable: Manufacturing and experimental study.” J. Compos Constr. 19 (6): 04015010. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000563.10.1061/(ASCE)CC.1943-5614.0000563 ↗
34. Taha, M. M. R., and N. G. Shrive. 2003. “New concrete anchors for carbon fiber-reinforced polymer post-tensioning tendons—Part 1: State-of-the-art review/design.” ACI Struct. J. 100 (1): 86–95. https://doi.org/10.1016/S0886-7798(03)00002-6.
35. 10.1016/j.conbuildmat.2017.10.13410.1016/j.conbuildmat.2017.10.134 ↗
36. Wang, X. 2007. Numerical analysis of ANSYS engineering structure. [In Chinese.] Beijing: China Communications Press.
37. 10.1016/j.compositesb.2012.06.00110.1016/j.compositesb.2012.06.001 ↗
38. Xie, G., R. Liu, B. Chen, M. Li, and T. Shi. 2015. “Synergistic effect of a new wedge-bond type anchor for CFRP tendons.” [In Chinese.] J. Cent. South Univ. 22 (6): 2260–2266. https://doi.org/10.1007/s11771-015-2750-0.10.1007/s11771-015-2750-0 ↗
39. Xie, X., X. Li, and Y. Shen. 2014. “Static and dynamic characteristics of a long-span cable-stayed bridge with CFRP cables.” Materials 7 (6): 4854–4877. https://doi.org/10.3390/ma7064854.10.3390/ma7064854 ↗
40. 10.1061/(ASCE)CC.1943-5614.000053710.1061/(ASCE)CC.1943-5614.0000537 ↗
41. Zhu-Ge, P., S. Qiang, and S. Hou. 2010. “Experimental investigation of wedge-anchor parameters for CFRP tendons.” [In Chinese.] J. South Jiaotong Univ. 45 (4): 514–520.
42. Zhu-Ge, P., Y. Yu, C. S. Cai, Z. Zhang, and Y. Ding. 2019. “Mechanical behavior and optimal design method for innovative CFRP cable anchor.” J. Compos. Constr. 23 (1): 04018067. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000900.10.1061/(ASCE)CC.1943-5614.0000900 ↗
43. Zhu-Ge, P., Z. Zhang, Y. Ding, and P. Lu. 2014. “Tensile performance with bending of CFRP tendon used in civil engineering.” [In Chinese.] Acta Mater. Compos. Sin. 31 (5): 1300–1305.
44. 10.1016/j.compstruct.2017.06.05710.1016/j.compstruct.2017.06.057 ↗