journal article·2006-06

Structural Retrofitting of Deteriorated Concrete Lighting Poles Using FRP Sheets in Wet Layup—Field Application

Ali H. Chahrour, Khaled A. Soudki

Publisher page

Abstract

This paper investigates the structural retrofit of deteriorated reinforced concrete lighting poles using wet layup of fiber reinforced polymer (FRP) sheets. The study comprised of four full-scale Class B damaged poles and one full-scale Class C undamaged pole. Each pole was 14,000 mm long with a base diameter of 350 mm linearly tapered to a tip diameter of 165 mm. The damaged poles were reinforced with nine No. 10 steel bars each, whereas the undamaged pole had four prestressed steel strands of 3/8 in. (9.5 mm) diameter. Four different in situ applicable repair schemes, one for each damaged pole, involving the application of E-glass or carbon FRP lateral confining wraps only (unidirectional) or coupled with additional longitudinal flexure sheets (bidirectional) were investigated. The adequacy of the retrofit works was checked through full-scale bending test of the poles in accordance with specification of the Canadian Standard Association. All four repaired poles exceeded the CSA design transverse loading requirement for Class B poles. In addition, the bidirectional E-glass and carbon FRP repaired poles exceeded the benchmark performance of the undamaged Class C pole as a percentage of the required design load with the E-glass pole exhibiting the best performance.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Load-Bearing Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Research Assistant Professor, Dept. of Civil Engineering, Univ. of Waterloo, Waterloo ON, Canada N2L 3G1.

Canada Research Chair Professor, Univ. of Waterloo, Waterloo ON, Canada N2L 3G1 (corresponding author).

References (9)

Show source-provided references
1. Canadian Standards Association International (CSA International). (2000). “Concrete Poles.” CAN/CSA-A14-00 CSA International National Standard of Canada.
2. 10.1061/(ASCE)1090-0268(2002)6:2(123)10.1061/(ASCE)1090-0268(2002)6:2(123) ↗
3. Ibrahim S. (2000). “Performance evaluation of fiber-reinforced polymer poles for transmission lines.” Ph.D. thesis Univ. of Manitoba Winnipeg Man. Canada.
4. Katsumata H. Kobatake Y. and Takeda T. (1988). “A study on strengthening with carbon fiber for earthquake-resistant capacity of existing reinforced concrete columns.” Proc. 7th 9WCEE 517–522.
5. 10.1061/JSDEAG.000295710.1061/JSDEAG.0002957 ↗
6. 10.1061/(ASCE)0733-9445(1997)123:5(583)10.1061/(ASCE)0733-9445(1997)123:5(583) ↗
7. Nanni A. Norris M. S. and Bradford N. M. (1993). “Lateral confinement of concrete using FRP reinforcement.” Proc. Int. Symp. on FRP Reinforcement: ACI SP-138 Vancouver Canada American Concrete Institute Farmington Hills Mich. 193–209.
8. 10.1016/0950-0618(95)00021-710.1016/0950-0618(95)00021-7 ↗
9. 10.1061/(ASCE)1090-0268(1997)1:2(52)10.1061/(ASCE)1090-0268(1997)1:2(52) ↗