Seismic Performance of Square Concrete Columns Confined with Glass Fiber–Reinforced Polymer Ties
Source abstract
Abstract
This paper assesses the seismic response of square concrete columns internally confined with glass fiber–reinforced polymers (GFRP). Tests were conducted under simulated earthquake loads on eight full-scale 305×305 mm columns reinforced with GFRP rectilinear ties and steel longitudinal bars. Shear versus deflection and moment versus curvature responses along with various ductility parameters were used to evaluate the performance of the columns. Results showed that the GFRP ties provide effective confinement to the concrete core until a rupture strain much larger than the steel yield strain. The influence of tie configuration on specimen behavior was found to be significant. An approximately 4% ultimate drift ratio was observed for properly confined columns tested under axial load of 42% of the column axial load capacity. The current design code provisions and guidelines for GFRP ties were found to be ambiguous and lacking in several aspects; suggestions are made for improvement.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Response to Dynamic Loads · Structural Load-Bearing Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Ph.D. Candidate, Dept. of Civil Engineering, Univ. of Toronto, 35 St. George St., Toronto, ON, Canada M5S 1A4 (corresponding author). ORCID: .
Professor, Dept. of Civil Engineering, Univ. of Toronto, 35 St. George St., Toronto, ON, Canada M5S 1A4.
References (26)
Show source-provided references
1. 10.1061/(ASCE)CC.1943-5614.000043810.1061/(ASCE)CC.1943-5614.0000438 ↗
2. 10.1061/(ASCE)CC.1943-5614.000063710.1061/(ASCE)CC.1943-5614.0000637 ↗
3. Bae S. 2005. “Seismic performance of full-scale reinforced concrete columns.” Ph.D. thesis Dept. of Civil Architectural and Environmental Engineering Univ. of Texas at Austin.
4. 10.1061/(ASCE)0733-9445(1998)124:9(999)10.1061/(ASCE)0733-9445(1998)124:9(999) ↗
5. Behavior of full-scale glass fiber-reinforced polymer reinforced concrete columns under axial load
6. 10.1139/l03-05510.1139/l03-055 ↗
7. 10.1061/(ASCE)CC.1943-5614.000073410.1061/(ASCE)CC.1943-5614.0000734 ↗
8. 10.1061/(ASCE)CC.1943-5614.000067010.1061/(ASCE)CC.1943-5614.0000670 ↗
9. Johal K. S. 2016. “Investigation of creep rupture phenomenon in glass fibre reinforced polymer (GFRP) stirrups.” M.A.Sc. thesis Dept. of Civil Engineering Univ. of Toronto.
10. 10.1139/cjce-2012-052210.1139/cjce-2012-0522 ↗
11. 10.1016/j.conbuildmat.2016.02.21910.1016/j.conbuildmat.2016.02.219 ↗
12. FRP-confined circular columns under simulated seismic loads
13. Durability of GFRP composite rods
14. Fiberglass reinforced concrete slab and beams10.1061/JSDEAG.0004559 ↗
15. NSERC (Natural Sciences and Engineering Research Council of Canada). 2012. “Bridging the gap composites extend infrastructure life.” Accessed June 15 2017. http://www.nserc-crsng.gc.ca/Media-Media/ImpactStory-ArticlesPercutant_eng.asp?ID=1047.
16. 10.1061/(ASCE)CC.1943-5614.000035710.1061/(ASCE)CC.1943-5614.0000357 ↗
17. Behavior and performance of GFRP reinforced concrete columns with various types of stirrups10.1155/2015/237231 ↗
18. Schöck ComBAR. 2013. “Technical information.” Accessed August 20 2016. http://www.schoeck-combar.com/upload/documents/flashbook/comb/combar_glasfaserbewehrung/technical_information_schoeck_combar__13-11-14_3075/index.html#18.
19. Schöck ComBAR. 2015. “Technical information.” Accessed October 21 2017. https://www.schoeck.co.uk/view/5470/Technical_Information_Schoeck_Combar_international%5B5470%5D.pdf.
20. Confined concrete columns with stubs
21. Strength and ductility of tied concrete columns10.1061/JSDEAG.0005416 ↗
22. Glass fiber-reinforced polymer-reinforced circular columns under simulated seismic loads
23. 10.1061/(ASCE)CC.1943-5614.000077410.1061/(ASCE)CC.1943-5614.0000774 ↗
24. Concrete columns reinforced longitudinally and transversally with glass fiber-reinforced polymer bars
25. Behaviour of concentrically loaded fiber-reinforced polymer reinforced concrete columns with varying reinforcement types and ratios
26. Xue W. X. Hu and Z. Fang. 2014. “Experimental studies of GFRP reinforced concrete columns under static eccentric loading.” In Proc. 7th Int. Conf. on Fiber Reinforced Polymer (FRP) Composites in Civil Engineering. Kingston ON Canada: International Institute for FRP in Construction.