journal article·2017-10

Vertical and Lateral Behavior of Unbonded Fiber-Reinforced Elastomeric Isolators

Yasser M. Al-Anany, Niel C. Van Engelen, Michael J. Tait

Publisher page

Abstract

Fiber-reinforced elastomeric isolators (FREIs) are relatively lightweight, can be cut to the required size from larger pads, and can be placed unbonded (i.e., unfastened) between the supports. The two major geometric parameters that influence the vertical and lateral response of unbonded fiber-reinforced elastomeric isolators (U-FREIs) are the shape factor and the aspect ratio. The vertical response is strongly influenced by the shape factor, while the aspect ratio is the controlling parameter for the stable response of U-FREIs under lateral displacement. This paper describes an experimental study on the vertical and lateral response of U-FREIs under different loading conditions in both the lateral and vertical directions. Three U-FREIs, with different aspect ratios and shape factors, were tested using a multiload test apparatus. Results from vertical tests indicate that, in addition to the shape factor, the vertical stiffness is influenced by the vertical rate of loading. Furthermore, it was found that the static lateral offset did not significantly affect the vertical stiffness of the isolators considered. These observations are in part attributed to the composite action of the fiber reinforcement and the elastomer.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Engineering and Vibration Analysis · Vibration Control and Rheological Fluids · Seismic Performance and Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Structural Designer, Associated Engineering (Ont.) Ltd., 110A Hannover Dr., St. Catharines, ON, Canada L2W 1A4.

Project Scientist, Rowan Williams Davies & Irwin, Inc., 600 Southgate Dr., Guelph, ON, Canada N1G 4P6.

Professor, Dept. of Civil Engineering, McMaster Univ., 1280 Main St. West, Hamilton, ON, Canada L8S 4L7 (corresponding author).

References (31)

Show source-provided references
1. 10.1016/j.compstruct.2015.07.04210.1016/j.compstruct.2015.07.042 ↗
2. Al-Anany Y. Van Engelen N. C. Tait M. and Konstantinidis D. (2016). “Examination of fiber reinforced elastomeric isolators for bridge applications.” Proc. 8th World Congress on Joints Bearings and Seismic Systems for Concrete Structures International Joints and Bearings Research Council Atlanta.
3. 10.1061/(ASCE)0733-9399(2006)132:1(54)10.1061/(ASCE)0733-9399(2006)132:1(54) ↗
4. 10.1016/S0167-6636(01)00102-810.1016/S0167-6636(01)00102-8 ↗
5. 10.1002/zamm.20090036510.1002/zamm.200900365 ↗
6. 10.1016/j.ijplas.2005.09.00510.1016/j.ijplas.2005.09.005 ↗
7. 10.1016/j.ijsolstr.2013.06.01610.1016/j.ijsolstr.2013.06.016 ↗
8. Chopra A. K. · 2012
9. 10.1177/002199831038831910.1177/0021998310388319 ↗
10. 10.1016/j.engstruct.2012.10.02810.1016/j.engstruct.2012.10.028 ↗
11. 10.1016/j.engstruct.2016.11.03610.1016/j.engstruct.2016.11.036 ↗
12. 10.1007/978-1-4471-0971-610.1007/978-1-4471-0971-6 ↗
13. Analysis of fiber-reinforced elastomeric isolators
14. 10.1193/1.150333910.1193/1.1503339 ↗
15. 10.2140/jomms.2008.3.138310.2140/jomms.2008.3.1383 ↗
16. Kelly J. M. and Konstantinidis D. (2007). “Low-cost seismic isolators for housing in highly seismic developing countries.” Proc. 10th World Conf. on Seismic Isolation Energy Dissipation and Active Vibrations Control of Structures Anti-Seismic Systems International Society Bologna Italy.
17. 10.1016/S0022-5096(01)00136-310.1016/S0022-5096(01)00136-3 ↗
18. 10.1016/S0924-0136(02)00713-610.1016/S0924-0136(02)00713-6 ↗
19. 10.1016/j.engstruct.2008.03.01010.1016/j.engstruct.2008.03.010 ↗
20. 10.1002/978047017274210.1002/9780470172742 ↗
21. Seismic isolation of a shear wall structure using rectangular fiber-reinforced elastomeric isolators
22. 10.1016/j.engstruct.2015.08.01910.1016/j.engstruct.2015.08.019 ↗
23. Sciascetti A. Al-Anany Y. and Tait M. J. (2016). “The effect of temperature on the lateral response of unbonded fiber-reinforced elastomeric isolators ” Proc. 5th Int. Materials Specialty Conf. Canadian Society for Civil Engineering Montreal.
24. 10.12989/sem.2014.49.3.39510.12989/sem.2014.49.3.395 ↗
25. 10.1177/002199830810632210.1177/0021998308106322 ↗
26. 10.1061/(ASCE)0733-9445(2008)134:10(1627)10.1061/(ASCE)0733-9445(2008)134:10(1627) ↗
27. 10.1002/stc.22510.1002/stc.225 ↗
28. 10.1016/j.compstruct.2010.07.00910.1016/j.compstruct.2010.07.009 ↗
29. 10.1002/eqe.266510.1002/eqe.2665 ↗
30. Model of the shear behavior of unbondedfiber-reinforced elastomeric isolators
31. 10.1061/(ASCE)0733-9445(2007)133:9(1227)10.1061/(ASCE)0733-9445(2007)133:9(1227) ↗