Evaluation of Masonry Deep Beams Externally Strengthened with CFRP Sheets
Source abstract
Abstract
In this study, carbon fiber-reinforced polymer (CFRP) sheets were examined as a means to strengthening existing masonry walls allowing for efficient creation of doors, windows, and passage openings. The research reported here deals with eight masonry walls made with concrete blocks, subjected to three-point quasistatic loading. The parameters examined include the reinforcement configuration and their amount. While CFRP sheets were used as external reinforcement, companion studies were carried out with conventional steel rebars. Test results indicate an increase of 180% in shear strength of the reinforced walls as compared to reference unreinforced walls. Load-deflection relationships indicate that the combined plain masonry and CFRP laminate system possessed some nonlinear deformability. The use of CFRP laminates on the walls was found to have an influence on the mode of failure. Anchoring the CFRP laminates at both support regions helped in using a larger portion of the strength of the laminates. The reinforced walls exhibited diagonal shear cracks that developed at a much slower rate and were ultimately accompanied by the peeling off of the CFRP laminates.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Currently, Structural Engineer, WorleyParsons, 5008, 86th St., Edmonton, AB, Canada T6E 5S2.
Assistant Professor, Dept. of Civil and Environmental Engineering, Univ. of Alberta, Edmonton, AB, Canada T6G 2G7 (corresponding author).
Professor, Dept. of Civil and Environmental Engineering, Univ. of Alberta, Edmonton, AB, Canada T6G 2G7.
Retired; formerly, Professor, Dept. of Civil and Environmental Engineering, Univ. of Alberta, Edmonton, AB, Canada T6G 2G7.
References (18)
Show source-provided references
1. 10.1061/(ASCE)1090-0268(2001)5:2(76)10.1061/(ASCE)1090-0268(2001)5:2(76) ↗
2. ASTM. (2008a). “Standard procedure for mortar for unit masonry.” C270-08a West Conshohocken Pa.
3. ASTM. (2008b). “Standard test methods and definitions for mechanical testing of steel products.” A370-08b West Conshohocken Pa.
4. 10.1061/(ASCE)0733-9445(2001)127:7(784)10.1061/(ASCE)0733-9445(2001)127:7(784) ↗
5. CSA. (1994). “Masonry design for buildings (limit states design).” S304.1-94 Canadian Standards Association Etobicoke Ont. 1–94.
6. CSA. (2004). “Design of concrete structures.” A23.3-04 Canadian Standards Association Mississauga Ont.
7. Bond of FRP laminates to concrete
8. FRP reinforcement of stone bridges: Unilateral contact models and limit analysis
9. Foster P. B. Gergely J. Young D. T. McGinley W. M. and Corzo A. (2005). “FRP repair methods for unreinforced masonry buildings subject to cyclic loading.” Proc. ACI-SP 230: 7th Int. Symp. on ‘FRP for Concrete Structures’ Vol. 1 C. K. Shield J. P. Busel S. L. Walkup and D. D. Gremel eds. American Concrete Institute Farmington Hills Mich. 289–306.
10. 10.1016/j.cemconcomp.2004.04.00210.1016/j.cemconcomp.2004.04.002 ↗
11. 10.1016/S1359-8368(01)00032-410.1016/S1359-8368(01)00032-4 ↗
12. 10.1080/0961321840854530110.1080/09613218408545301 ↗
13. Miao H. Cheng J. J. R. and Elwi A. (2005). “CFRP sheets application to masonry shear walls with openings.” Structural Engineering Rep. No. 256 Univ. of Alberta Edmonton Alta.
14. Reinforced concrete deep beams-shear strength model and design formula
15. 10.1061/(ASCE)0733-9445(2004)130:10(1534)10.1061/(ASCE)0733-9445(2004)130:10(1534) ↗
16. 10.1016/S0958-9465(97)00028-010.1016/S0958-9465(97)00028-0 ↗
17. 10.1061/(ASCE)1090-0268(2006)10:3(275)10.1061/(ASCE)1090-0268(2006)10:3(275) ↗
18. 10.1016/j.compositesb.2004.06.00110.1016/j.compositesb.2004.06.001 ↗