journal article·2023-12

Axial Compressive Behavior of Predamaged Concrete Cylinders Retrofitted with CFRP Grid-Reinforced ECC

Gao Ma, Chunxu Hou, Hyeon-Jong Hwang, Zhaoyang Wang

Publisher page

Abstract

A fiber-reinforced polymer grid-reinforced engineered cementitious composite (FRPECC) is a promising strengthening composite that addresses the drawbacks of FRP and textile-reinforced mortar (TRM). The present study focused on the axial compressive behavior and constitutive models of predamaged concrete repaired with carbon FRP grid-reinforced ECC (CFRPECC). The test parameters included predamage level, grid number, and concrete strength. The test results indicated that compared with plain concrete, the peak stress (strength), strain at peak stress (peak strain), and energy dissipation capacities of CFRPECC-retrofitted predamaged concrete increased by 9%–82%, 28%–96%, and 60%–322%, respectively. The improvement increased with the number of CFRP grids and ECC thickness but decreased with concrete strength. On the other hand, the strength and elastic modulus of concrete after retrofitting degraded with an increase in the predamage level, especially when the concrete was severely damaged, while the peak strain and lateral rupture strain were barely influenced. When the predamage level increased, the enhancement of strength decreased from 41%–106% to 9%–60%. CFRPECC directly carried 11.0%–22.7% of the strength of the retrofitted concrete columns. The enhancements of strength and elastic modulus after retrofitting were mainly attributed to the confinement and axial stiffness of CFRPECC, respectively. Further, models for the strength, peak strain, and stress–strain relationship were developed for CFRPECC-retrofitted predamaged concrete. The applicability of the proposed models was verified by test results of the existing studies.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

College of Civil Engineering, Hunan Univ., Changsha 410082, China; Key Laboratory for Damage Diagnosis of Engineering Structures of Hunan Province, Hunan Univ., Changsha 410082, Hunan, China (corresponding author). ORCID: .

College of Civil Engineering, Hunan Univ., Changsha 410082, China. ORCID: .

School of Architecture, Konkuk Univ., Seoul 05029, Korea. ORCID: .

College of Civil Engineering, Hunan Univ., Changsha 410082, China.

References (43)

Show source-provided references
1. ACI (American Concrete Institute). 2020. Guide to design and construction of externally bonded fabric-reinforced cementitious matrix systems for repair and strengthening concrete and masonry structures. ACI 549.4 R-20. Farmington, MI: ACI.
2. 10.1016/j.conbuildmat.2018.04.16110.1016/j.conbuildmat.2018.04.161 ↗
3. 10.1016/j.compstruct.2018.11.09310.1016/j.compstruct.2018.11.093 ↗
4. ASTM. 2015. Standard test method for determining tensile properties of geogrids by the single or multi-rib tensile method. ASTM D6637/D6637M-15. West Conshohocken, PA: ASTM.
5. Bournas, D. A., P. V. Lontou, C. G. Papanicolaou, and T. C. Triantafillou. 2007. “Textile-reinforced mortar versus fiber-reinforced polymer confinement in reinforced concrete columns.” ACI Struct. J. 104 (6): 740.
6. 10.1016/j.engstruct.2021.11265110.1016/j.engstruct.2021.112651 ↗
7. China Architecture & Building. 1999. Method of testing cements—Determination of strength. [In Chinese.] GBT 17671-1999. Beijing: China Architecture & Building.
8. China Architecture & Building. 2010. Code for design of concrete structures. [In Chinese.] GB 50010-2010. Beijing: China Architecture & Building.
9. China Architecture & Building. 2019. Standard for test method of mechanical properties on ordinary concrete. [In Chinese.] GB/T 50081-2019. Beijing: China Architecture & Building.
10. 10.1061/(ASCE)CC.1943-5614.000060310.1061/(ASCE)CC.1943-5614.0000603 ↗
11. 10.1061/(ASCE)CC.1943-5614.000011410.1061/(ASCE)CC.1943-5614.0000114 ↗
12. 10.1016/j.conbuildmat.2020.11835710.1016/j.conbuildmat.2020.118357 ↗
13. 10.1080/15732479.2019.170895810.1080/15732479.2019.1708958 ↗
14. 10.1016/j.conbuildmat.2017.01.08310.1016/j.conbuildmat.2017.01.083 ↗
15. 10.1016/j.conbuildmat.2016.01.01010.1016/j.conbuildmat.2016.01.010 ↗
16. 10.1061/(ASCE)0899-1561(2008)20:2(169)10.1061/(ASCE)0899-1561(2008)20:2(169) ↗
17. Jiang, J. F., and K. Sui. 2019. “Experimental study of compression performance of concrete cylinder strengthened by textile reinforced engineering cement composites.” Acta Mater. Compos. Sin. 36 (8): 1957–1967.
18. 10.1016/j.engstruct.2007.01.01010.1016/j.engstruct.2007.01.010 ↗
19. JSCE (Japan Society of Civil Engineers). 2008. Recommendations for design and construction of high performance fiber reinforced cement composites with multiple fine cracks. Tokyo: JSCE.
20. 10.1061/(ASCE)1090-0268(2004)8:6(539)10.1061/(ASCE)1090-0268(2004)8:6(539) ↗
21. 10.1061/(ASCE)0733-9399(1998)124:8(892)10.1061/(ASCE)0733-9399(1998)124:8(892) ↗
22. 10.1016/j.compositesb.2018.08.05910.1016/j.compositesb.2018.08.059 ↗
23. 10.1016/j.engstruct.2015.11.02210.1016/j.engstruct.2015.11.022 ↗
24. Li, X., K. Chen, P. Hu, W. He, L. Xiao, and R. Zhang. 2020. “Effect of ECC jackets for enhancing the lateral cyclic behavior of RC bridge columns.” Eng. Struct. 219: 110714.
25. 10.1016/j.engstruct.2017.01.01510.1016/j.engstruct.2017.01.015 ↗
26. 10.1016/S1359-835X(03)00250-110.1016/S1359-835X(03)00250-1 ↗
27. 10.1061/(ASCE)CC.1943-5614.000111810.1061/(ASCE)CC.1943-5614.0001118 ↗
28. 10.1061/(ASCE)CC.1943-5614.000103410.1061/(ASCE)CC.1943-5614.0001034 ↗
29. 10.1016/j.conbuildmat.2018.02.17210.1016/j.conbuildmat.2018.02.172 ↗
30. 10.1061/(ASCE)0899-1561(1994)6:4(513)10.1061/(ASCE)0899-1561(1994)6:4(513) ↗
31. 10.1061/(ASCE)0733-9445(1988)114:8(1804)10.1061/(ASCE)0733-9445(1988)114:8(1804) ↗
32. 10.1016/j.conbuildmat.2017.02.15810.1016/j.conbuildmat.2017.02.158 ↗
33. 10.1061/(ASCE)1090-0268(1998)2:4(175)10.1061/(ASCE)1090-0268(1998)2:4(175) ↗
34. 10.1061/(ASCE)CC.1943-5614.000075510.1061/(ASCE)CC.1943-5614.0000755 ↗
35. 10.1016/j.engstruct.2012.06.01010.1016/j.engstruct.2012.06.010 ↗
36. 10.1061/(ASCE)1090-0268(2007)11:5(514)10.1061/(ASCE)1090-0268(2007)11:5(514) ↗
37. Teng, J. G., J. F. Chen, S. T. Smith, and L. Lam. 2002. FRP strengthened RC structures. New York: Wiley.
38. 10.1016/j.conbuildmat.2016.04.15810.1016/j.conbuildmat.2016.04.158 ↗
39. Zheng, Y. Z., W. W. Wang, K. M. Mosalam, and Z. F. Zhu. 2019. “Mechanical behavior of ultra-high toughness cementitious composite strengthened with fiber reinforced polymer grid.” Compos. Struct. 184: 1–10. https://doi.org/10.1016/j.compstruct.2017.09.073.10.1016/j.compstruct.2017.09.073 ↗
40. 10.1061/(ASCE)MT.1943-5533.000103410.1061/(ASCE)MT.1943-5533.0001034 ↗
41. 10.1016/j.compstruct.2011.08.02210.1016/j.compstruct.2011.08.022 ↗
42. 10.1061/(ASCE)CC.1943-5614.000089110.1061/(ASCE)CC.1943-5614.0000891 ↗
43. 10.1061/(ASCE)CC.1943-5614.000116810.1061/(ASCE)CC.1943-5614.0001168 ↗