journal article·2007-10

Effect of Size on the Failure of Geometrically Similar Concrete Beams Strengthened in Shear with FRP Strips

Christopher K. Y. Leung, Zhongfan Chen, Stephen Lee, Mandy Ng, Ming Xu, Jianmao Tang

Publisher page

Abstract

Fiber reinforced plastics (FRP) are commonly used for the strengthening of concrete members. For shear strengthening of beams, FRP strips can be bonded to the sides of the member alone, to both the sides and the bottom (i.e., the U configuration), or wrapped around the whole beam. For the various strengthening configurations, empirical equations have been proposed for predicting the contribution of strips to the shear capacity of the member. However, for the same strengthened member, the equations recommended by different design guidelines (American Concrete Institute, International Federation for Structural Concrete, and Japan Society for Civil Engineers) predict different shear capacities. Moreover, as the equations were obtained through the fitting of laboratory data on relatively small beams, their applicability to beams of practical sizes have not really been assessed. In the present investigation, geometrically similar beams with depth of 180, 360, and 720mm were retrofitted in shear with carbon FRP strips in both the U configuration and fully wrapped configuration. The retrofitted members were tested to failure to (1) provide data on beams of practical sizes for verification of design equations and (2) investigate if the strengthening effectiveness is similar for small and large beams. Measured FRP contribution to the shear capacity is also compared to predictions from equations in the various guidelines. Based on our findings, for beams retrofitted with strips in the U configuration, the strengthening effectiveness may significantly decrease with member size, and none of the available design equations can consistently provide conservative values for the shear capacity. For beams with fully wrapped strips, strengthening effectiveness is independent of member size, and the FIB equation appears to be most appropriate for practical design.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Professor, Dept. of Civil Engineering, Hong Kong Univ. of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China.

Professor, Dept. of Civil Engineering, Southwest Univ., Nanjing, China.

Associate Director, Advanced Engineering Materials Facility, Hong Kong Univ. of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China.

Research Assistant, Advanced Engineering Materials Facility, Hong Kong Univ. of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China.

References (13)

Show source-provided references
1. American Concrete Institute · 2002
2. 10.1016/S0141-0296(02)00208-010.1016/S0141-0296(02)00208-0 ↗
3. Japan Society of Civil Engineers · 2001
4. Kamiharako A. Maruyama K. Takada K. and Shimomura T. (1997). “Evaluation of shear contribution of FRP sheets attached to concrete beams.” Nonmetallic (FRP) Reinforcement for Concrete Structures Proc. 3rd Int. Symp. Vol. 1 Japan Concrete Institute Tokyo 467–474.
5. 10.1061/(ASCE)1090-0268(1998)2:4(195)10.1061/(ASCE)1090-0268(1998)2:4(195) ↗
6. 10.1016/S0950-0618(02)00002-810.1016/S0950-0618(02)00002-8 ↗
7. 10.1016/0950-0618(95)00071-210.1016/0950-0618(95)00071-2 ↗
8. 10.1061/(ASCE)1090-0268(2002)6:2(104)10.1061/(ASCE)1090-0268(2002)6:2(104) ↗
9. Taerwe L. Khalil H. and Matthys S. (1997). “Behaviour of RC beams strengthened in shear by external CFRP sheets.” Nonmetallic (FRP) Reinforcement for Concrete Structures Proc. 3rd Int. Symposium Vol. 1 Japan Concrete Institute Tokyo 483–490.
10. 10.1007/BF0001316110.1007/BF00013161 ↗
11. Teng J. G. · 2002
12. Shear strengthening of reinforced concrete beams using epoxy-bonded FRP composites