journal article·2013-04

Effect of Prestressing on the Performance of GFRP-Reinforced Concrete Slab Bridge Strips

Martin Noël, Khaled Soudki

Publisher page

Abstract

Deterioration of reinforced concrete structures caused by corrosion of steel reinforcement is currently a major concern affecting the safety and functionality of our infrastructure. Fiber-reinforced polymer (FRP) materials have shown tremendous potential as an alternative reinforcement for reinforced and prestressed concrete structures. FRPs have been used in a wide variety of structural applications, from reinforced concrete deck slabs to posttensioned parking garages. However, one promising application for FRP reinforcing bars which has yet to be investigated thoroughly is their use in reinforced concrete slab bridges. This paper presents the results of an experimental study on 10 full-scale glass FRP (GFRP)-reinforced slab bridge strips posttensioned with 0, 2, or 4 carbon FRP (CFRP) tendons with and without shear reinforcement. The tendons were either fully bonded or fully nonbonded to evaluate the effect of bond on the serviceability and ultimate performance of the slabs, particularly in terms of their deformability. Based on the test results, the addition of prestressed CFRP tendons resulted in significantly improved serviceability and ultimate load-carrying capacity with good deformability.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Ph.D. Candidate, Dept. of Civil and Environmental Engineering, Univ. of Waterloo, Waterloo, MB, Canada N2L 3G1.

Professor and Canada Research Chair, Dept. of Civil and Environmental Engineering, Univ. of Waterloo, Waterloo, MB, Canada N2L 3G1 (corresponding author).

References (12)

Show source-provided references
1. American Concrete Institute (ACI). (2004). “Prestressing concrete structures with FRP tendons.” ACI 440.4R-04 Detroit.
2. American Concrete Institute (ACI). (2006). “Guide for the design and construction of structural concrete reinforced with FRP bars.” ACI 440.1R-06 Detroit.
3. Alkhairi F. M. (1991). “On the behavior of concrete beams prestressed with unbonded internal and external tendons.” Ph.D. thesis Univ. of Michigan Ann Arbor MI.
4. Burgoyne C. J. (1993). “Should FRP be bonded to concrete?” Fiber-reinforced-plastic reinforcement for concrete structures American Concrete Institute Vancouver BC 347–366.
5. Canadian Standards Association (CSA). (2010). “Canadian highway bridge design code.” CAN/CSA S6-10 Toronto.
6. Fico R. Galati N. Prota A. and Nanni A. (2006). “Southview bridge rehabilitation in Rolla Missouri: Design and construction volume 1.” Rep. Prepared for the U.S. Dept. of Transportation Center for Infrastructure Engineering Studies Univ. Transportation Center Program Univ. of Missouri-Rolla Rolla MO.
7. Galati N. Boschetto G. Rizzo A. Nanni A. and Parretti R. (2004). “Pre-construction investigation for the rehabilitation of a bridge using internal FRP technology.” 4th Int. Conf. on Advanced Composite Materials in Bridges and Structures Canadian Society for Civil Engineering Montréal 1–8.
8. Experimental study of influence of bond on flexural behavior of concrete beams pretensioned with aramid fiber reinforced plastics
9. Stresses in unbonded prestressing tendons at ultimate: Recommendation
10. 10.1139/l11-12610.1139/l11-126 ↗
11. Noël M. Soudki K. and El-Sayed A. (2011). “Flexural behavior of FRP-RC slabs post-tensioned with CFRP tendons.” Fiber reinforced polymer reinforcement for reinforced concrete structures ACI SP-275 American Concrete Institute Farmington Hills MI 59-1–59-20.
12. Post-Tensioning Institute (PTI) · 2003