Performance of GFRP-Reinforced Concrete Circular Short Columns under Concentric, Eccentric, and Flexural Loads
Source abstract
Abstract
This paper presents test results of seven large-scale circular concrete columns reinforced with either steel or glass fiber-reinforced polymer (GFRP) reinforcement. The columns measured 355 mm in diameter and 1,750 mm in length and were tested to failure under concentric, eccentric, or four-point bending configuration. Test parameters included the reinforcement type (GFRP and steel), the GFRP spiral pitch (50 and 85 mm), and varying ratios of eccentricity-to-column diameter (e/D = 0, 0.085, 0.17, and 0.34). The obtained axial capacity of the GFRP-reinforced concrete (RC) column was approximately 17% less than that of the steel-RC counterpart. However, for e/D = 0.085, the GFRP-RC column with a lesser spiral pitch exhibited approximately 10% more axial capacity than the column with a larger pitch. As the e/D ratio increases from 0 to 0.34 the axial capacity reduced by 32%, 39%, and 70% from the axial capacity of the concentric column. A “knee”-shaped interaction diagram for circular GFRP-RC columns was developed and compared with the predictions of available codes and guidelines for GFRP-RC structures.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Response to Dynamic Loads · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
M.Sc. Student, Dept. of Civil Engineering, Univ. of Manitoba, 15 Gillson St., Winnipeg, MB, Canada R3T 5V6.
Professor of Civil Engineering, Dept. of Civil Engineering, Univ. of Manitoba, 15 Gillson St., Winnipeg, MB, Canada R3T 5V6 (corresponding author). ORCID: .
References (24)
Show source-provided references
1. ACI (American Concrete Institute) · 2005
2. ACI (American Concrete Institute). · 2015
3. 10.1061/(ASCE)CC.1943-5614.000043810.1061/(ASCE)CC.1943-5614.0000438 ↗
4. 10.1139/l06-17310.1139/l06-173 ↗
5. Strength of rectangular concrete columns reinforced with fiber-reinforced polymer bars
6. CSA (Canadian Standards Association) · 2009
7. CSA (Canadian Standards Association) · 2017
8. CSA (Canadian Standards Association) · 2019
9. CSA (Canadian Standards Association) · 2019
10. CSA (Canadian Standards Association) · 2019
11. CSA (Canadian Standards Association) · 2019
12. Lateral displacement deformability of GFRP-RC slab-column edge connections
13. 10.1061/(ASCE)CC.1943-5614.000058210.1061/(ASCE)CC.1943-5614.0000582 ↗
14. 10.1061/(ASCE)CC.1943-5614.000073410.1061/(ASCE)CC.1943-5614.0000734 ↗
15. 10.14359/5168949810.14359/51689498 ↗
16. 10.1061/(ASCE)CC.1943-5614.000067010.1061/(ASCE)CC.1943-5614.0000670 ↗
17. 10.14359/5168806510.14359/51688065 ↗
18. Design for slenderness in concrete columns internally reinforced with fiber-reinforced polymer bars
19. 10.1061/(ASCE)BE.1943-5592.000059010.1061/(ASCE)BE.1943-5592.0000590 ↗
20. 10.14359/5170228210.14359/51702282 ↗
21. Pultrall Inc · 2019
22. 10.1002/pse.13910.1002/pse.139 ↗
23. Concrete columns reinforced longitudinally and transversally with glass fiber-reinforced polymer bars
24. 10.1061/(ASCE)CC.1943-5614.000035410.1061/(ASCE)CC.1943-5614.0000354 ↗