Bar Buckling in RC Columns Confined with Composite Materials
Source abstract
Abstract
The onset and evolution of bar buckling at the plastic hinge of old-type reinforced concrete (RC) columns confined with composite material [fiber-reinforced polymer (FRP) and textile-reinforced mortar (TRM)] jackets was investigated experimentally and analytically in this study. The interaction between composite jacket (or concrete cover, for unconfined concrete) and embedded longitudinal compression reinforcement at the onset and evolution of bar buckling was achieved through strain measurements of the compression reinforcement. Moreover, the implementation of a recent stress-strain confinement model, which relates lateral with axial strains, allowed the description and monitoring of the axial-lateral strain relationship at the base of the columns throughout the evolution of bar buckling. Based on the aforementioned model and the experimental measurements, the postbuckling behavior of columns was related to the jacket stiffness. Finally, a semiempirical expression that gives the drift ratio of RC columns at the onset of bar buckling was modified herein for the case of FRP- or TRM-jacketed columns.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Postdoctoral Researcher, European Laboratory for Structural Assessment, IPSC, JRC, T.P. 480, I-21020 Ispra (VA), Italy (corresponding author).
Professor, Dept. of Civil Engineering, Univ. of Patras, Patras GR-26500, Greece.
References (25)
Show source-provided references
1. 10.1061/(ASCE)0733-9445(2005)131:2(314)10.1061/(ASCE)0733-9445(2005)131:2(314) ↗
2. 10.1061/(ASCE)0733-9445(2005)131:7(1060)10.1061/(ASCE)0733-9445(2005)131:7(1060) ↗
3. Textile-reinforced mortar (TRM) versus FRP confinement in reinforced concrete columns
4. Flexural strengthening of RC columns with NSM FRP or stainless steel
5. 10.1061/(ASCE)CC.1943-5614.000002810.1061/(ASCE)CC.1943-5614.0000028 ↗
6. 10.1080/1363246060112571410.1080/13632460601125714 ↗
7. Chun S. S. and Park H. C. (2002). “Load carrying capacity and ductility of RC columns confined by carbon fiber reinforced polymer.” Proc. 3rd Int. Conf. on Composites in Infrastructure (CD-ROM) Univ. of Arizona San Francisco.
8. 10.1061/(ASCE)0733-9445(2002)128:9(1139)10.1061/(ASCE)0733-9445(2002)128:9(1139) ↗
9. European Committee for Standardization. (1993). “Methods of test for mortar for masonry—Part 11: Determination of flexural and compressive strength of hardened mortar.” EN 1015–11 Brussels.
10. Confinement model for axially loaded concrete confined by circular fiber-reinforced polymer tubes
11. 10.1016/S0141-0296(97)00166-110.1016/S0141-0296(97)00166-1 ↗
12. Behavior and modeling of concrete subject to variable confining pressure
13. 10.1061/(ASCE)1090-0268(2004)8:4(332)10.1061/(ASCE)1090-0268(2004)8:4(332) ↗
14. Effect of tie spacing on inelastic buckling of reinforcing bars
15. 10.1016/1359-8368(95)00019-410.1016/1359-8368(95)00019-4 ↗
16. 10.1061/(ASCE)0733-9445(1992)118:12(3268)10.1061/(ASCE)0733-9445(1992)118:12(3268) ↗
17. Influence of tension strain on buckling of reinforcement in concrete columns
18. 10.1061/(ASCE)0733-9445(1998)124:6(623)10.1061/(ASCE)0733-9445(1998)124:6(623) ↗
19. 10.1061/(ASCE)0733-9445(1999)125:6(605)10.1061/(ASCE)0733-9445(1999)125:6(605) ↗
20. 10.1061/(ASCE)1090-0268(1999)3:3(143)10.1061/(ASCE)1090-0268(1999)3:3(143) ↗
21. 10.1061/(ASCE)ST.1943-541X.000008810.1061/(ASCE)ST.1943-541X.0000088 ↗
22. 10.1016/j.engstruct.2004.02.00310.1016/j.engstruct.2004.02.003 ↗
23. 10.1061/(ASCE)1090-0268(2006)10:1(13)10.1061/(ASCE)1090-0268(2006)10:1(13) ↗
24. 10.1061/(ASCE)1090-0268(2007)11:2(201)10.1061/(ASCE)1090-0268(2007)11:2(201) ↗
25. Concrete confinement with textile-reinforced mortar jackets