Effect of Untreated Surface Disbonds on Performance of FRP-Retrofitted Concrete Beams
Source abstract
Abstract
Retrofitting concrete structures with externally bonded fiber-reinforced polymer (FRP) laminates has become an increasingly common practice. Disbonds at the concrete-FRP interface, if left untreated, may adversely affect the performance of the retrofitted system. Disbonds in the form of surface voids and cracks are the subject of this paper. Voids may occur due to poor compaction or defective formwork, or in the form of air entrapment between resin and FRP laminate during application. Cracks, on the other hand, generally result from loading. This study is comprised of a detailed experimental program and a nonlinear finite-element analysis. In the experiments, surface cracks were simulated by cutting slits in concrete, herein termed as surface cuts. The study shows that leaving surface disbonds untreated, within the considered range of disbond variables, does not have a significant impact on the overall structural performance. A threshold of 12.7 mm for void diameter was deemed conservative for structural performance. On the other hand, 38 mm spacing was considered an appropriate threshold for epoxy injection in crack widths between 0.25 and 0.8 mm. Hence, conservative thresholds in current practice may be revised accordingly, unless considered necessary to avoid environmental effects.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Structural Engineer, Walker Parking Consultants, 17049 El Camino Real, Ste 202, Houston, TX 77058.
Structural Engineer, EAC Consulting, Inc., 815 NW 57th Ave., Suite 402, Miami, FL 33126.
Professor and Dean, College of Engineering and Computing, Florida Int. Univ., Miami, FL 33174 (corresponding author).
References (16)
Show source-provided references
1. ACI Committee 440. (2008). “Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures.” ACI 440.2R-08 American Concrete Institute Detroit.
2. ANSYS 8.0 . (2003). ANSYS Inc. Canonsburg Pa.
3. 10.1061/(ASCE)1090-0268(1997)1:2(63)10.1061/(ASCE)1090-0268(1997)1:2(63) ↗
4. Delaney J. C. and Karbhari V. M. (2006). “The assessment of aspects related to defect criticality in CFRP strengthened concrete flexural members.” Rep. No. SSRP 06/11 Dept. of Structural Engineering Univ. of California-San Diego La Jolla Calif.
5. ICRI/ACI · 1999
6. Kaiser H. (2002). “Assessment of defect criticality and non-destructive monitoring of CFRP-rehabilitated civil structures.” MS thesis Univ. of California-San Diego La Jolla Calif.
7. Kalayci A. S. (2008). “Development of surface flaw thresholds for pre-cured fiber reinforced polymer and groove size tolerance for near surface mounted fiber reinforced polymer systems.” Ph.D. thesis Florida Int. Univ. Miami.
8. Mirmiran A. Shahawy M. Nanni A. and Karbhari V. (2004). “Bonded repair and retrofit of concrete structures using FRP composites-recommended construction specifications and process control manual.” NCHRP Rep. No. 514 Transportation Research Board Washington D.C.
9. Mirmiran A. Shahawy M. Nanni A. Karbhari V. Yalim B. and Kalayci A. S. (2008). “Recommended construction specifications and process control manual for repair and retrofit of concrete structures using bonded FRP composites.” NCHRP Rep. No. 609 Transportation Research Board Washington D.C.
10. Myers J. J. and Ekenel M. (2005). “Effect of environmental conditions during installation process on bond strength between CFRP laminate and concrete substrate.” Proc. 7th Int. Symp. on Fiber-Reinforced Polymer (FRP) Reinforcement for Concrete Structures (FRPRCS-7) American Concrete Institute Detroit.
11. Navada R. (2004). “A fracture mechanics approach to assessment of defect criticality in FRP rehabilitated concrete.” MS thesis Univ. of California-San Diego La Jolla Calif.
12. Puliyadi S. (2001). “Performance of CFRP sheet strengthened reinforced concrete beams in the presence of delamination and lap splice.” MS thesis Univ. of Missouri Rolla Mo.
13. 10.1016/1359-8368(95)00043-710.1016/1359-8368(95)00043-7 ↗
14. Telang N. M. Dumlao C. Mehrabi A. B. Ciolko A. T. and Gutierrez J. (2004). “Field inspection of service FRP bridge decks.” NCHRP Rep. No. 564 Transportation Research Board Washington D.C.
15. 10.1016/j.conbuildmat.2005.01.01110.1016/j.conbuildmat.2005.01.011 ↗
16. Yalim B. (2008). “Development of thresholds for surface preparation in repair systems with wet lay-up fiber reinforced polymers.” Ph.D. thesis Florida Int. Univ. Miami.