journal article·2019-05-01Open access

Influence of Different Connection Types on Mechanical Behavior of Girder Trusses

Zeli Que, Tongyu Hou, Yifan Gao, Qicheng Teng, Qiuyun Chen, Changju Wang, Cheng Chang

Abstract

The static test of two single light wood trusses and two girder trusses were carried out to explore the performance enhancement effect of girder trusses and the influence of different connection types on the mechanical behavior, which was studied through the comparison of the test results of four trusses. It is found that the girder trusses can show better load-carrying capacity and anti-deforming ability compared with which simply increases the cross-section size of the members. Because of the advantage of the connection materials and the non-fastening connection mechanism, the wood pin-connected truss has more ultimate bearing capacity which is 2.6 times of single truss, and better deformation resistance which is only 66.2% of the nailed one’s creep value.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Engineering and Vibration Analysis · Contact Mechanics and Variational Inequalities · Structural Load-Bearing Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (18)

Show source-provided references
1. Structural analysis of two king-post timber trusses: non-destructive evaluation and load-carrying tests10.1016/j.conbuildmat.2009.08.025 ↗
2. Test and load-bearing capacity of metal plate connected joint
3. Use and design of light-frame wooden structure
4. Modern timber bridges and their structure types
5. Size effects in timber explained by a modified weakest link theory10.1139/l86-030 ↗
6. Ministry of Housing and Urban-Rural Development of China · 2012
7. A review of the research of wood girder truss
8. The influence of bending performance by the variations in wood density and knot of SPF dimension lumber
9. Modes and causes of structural failure of timber structures
10. Standardization Administration of China · 2003
11. Standardization Administration of China · 2009
12. Standardization Administration of China · 2009
13. Standardization Administration of China · 2012
14. Standardization Administration of China · 2012
15. The influence of nail ductility on the load capacity of a glulam truss structure10.1016/j.engstruct.2004.01.012 ↗
16. Numerical simulation of framed joints in sawn-timber roof trusses10.5424/sjar/2008064-345 ↗
17. Xu · 2006
18. Size effects of width on tensile strength of visually-graded Chinese larch lumber