Lateral resistance performance of wood-frame shear walls with wooden nail connections: Experimental and finite element analysis
Source abstract
Abstract
Modern architecture and engineering increasingly favor timber structures due to their sustainability. Wooden nails, as eco-friendly alternatives to traditional metal connectors, offer promising potential for widespread adoption. This study analyzed the influence of various parameters on the shear performance of wooden nail connections through monotonic loading tests. Key factors examined included sheathing panel material (oriented strand board (OSB) and structural plywood (SP)), thickness (9.5 and 12 mm), as well as nail diameter (3.7 and 4.7 mm), spacing (50 and 100 mm), and cap configuration (with/without caps) on the mechanical behavior of the joints. Analyzing load-displacement curves and mechanical parameters (ultimate load, stiffness, ductility) reveals several key findings: nail cap design has minimal impact on shear performance compared to other factors; joints with SP sheathing panel material show significantly higher shear-bearing capacity than those with OSB. Stiffness and ductility vary across specimen groups, with group O9-4.7 (denoting OSB sheathing, 9.5 mm thickness, and 4.7 mm nail diameter) having the highest stiffness (1 332 N/mm) and group O12-4.7 (OSB sheathing, 12 mm thickness, and 4.7 mm nail diameter) showing superior ductility (3.47). Additionally, a comprehensive finite element (FE) simulation of full-size wood-frame shear walls using OpenSees software provides insights into the influence of sheathing panel form, material properties, and thickness on lateral resistance performance.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Wood Treatment and Properties · Masonry and Concrete Structural Analysis · Tree Root and Stability Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. Structural characteristics of light-frame wood shear walls with various construction detailing10.1016/j.engstruct.2019.110093 ↗
2. A predictive analytical model for the elasto-plastic behaviour of a light timber-frame shear-wall10.1016/j.conbuildmat.2015.06.025 ↗
3. The effect of some technological properties of plywood panels on seismic resistant performance of wooden shear wall
4. Dissipation in sheathing-to-framing connections of light-frame timber shear walls under seismic loads10.1016/j.engstruct.2020.110246 ↗
5. Development of a uniaxial hysteretic model for dowel-type timber joints in OpenSees10.1016/j.conbuildmat.2021.123112 ↗
6. Impact of moisture cycling on lateral resistance of resin-impregnated compressed beech nails in Radiata pine timber10.1080/20426445.2021.1906389 ↗
7. Experimental results on the role of sheathing-to-frame and base connections of a European timber framed shear wall10.1016/j.conbuildmat.2015.01.076 ↗
8. Monotonic and cyclic behaviour of wood frame shear walls for mid-height timber buildings10.1016/j.engstruct.2019.03.043 ↗
9. Lateral performance of midply wood shear walls with anchor tie-down system: experimental investigation and numerical simulation10.1016/j.conbuildmat.2019.117518 ↗
10. Plastic models for analysis of fully anchored light-frame timber shear walls10.1016/j.engstruct.2009.03.023 ↗
11. Wood nails to fix softwoods: characterization of structural deformation and lignin modification10.1007/s00107-018-1288-x ↗
12. A numerical and experimental investigation of non-linear deformation behaviours in light-frame timber walls10.1016/j.engstruct.2021.113599 ↗
13. Finite element analysis of glulam frame-shear wall structures
14. Racking deformations in wood shear walls10.1061/(ASCE)0733-9445(1985)111:2(257) ↗
15. Wood as a building material in the light of environmental assessment of full life cycle of four buildings10.1016/j.conbuildmat.2013.11.066 ↗
16. Simplified numerical approach for the lateral load analysis of light-frame wood shear wall structures10.1016/j.engstruct.2020.110921 ↗
17. The wood from the trees: the use of timber in construction10.1016/j.rser.2016.09.107 ↗
18. Novel nail-like wood connectors10.4028/www.scientific.net/AMR.778.647 ↗
19. Densified wooden nails for new timber assemblies and restoration works: a pilot research10.1016/j.conbuildmat.2015.06.045 ↗
20. Analysis of nail properties for joint design10.1016/j.engstruct.2018.06.071 ↗
21. OSB and GFB as sheathing materials for timber-framed shear walls: comparative study of seismic resistance10.1061/(ASCE)ST.1943-541X.0001293 ↗
22. Teng · 2020
23. Lateral loading performance of lightweight glubam shear walls10.1061/(ASCE)ST.1943-541X.0001751 ↗
24. Influence of repeated wetting and drying on withdrawal capacity of wooden nails and metal nails10.1016/j.conbuildmat.2023.133991 ↗
25. OpenSees simulation of shear performance of light steel keel composite wall and study on the influence of aspect ratio
26. Lateral performance for wood-frame shear walls: a critical review10.32604/jrm.2023.026773 ↗
27. Effect of repeated wetting and drying on withdrawal capacity and corrosion of nails in treated and untreated timber10.1016/j.conbuildmat.2021.122878 ↗
28. Lateral behavior of wood frame shear walls sheathed with densified plywood under monotonic loading10.1016/j.tws.2021.108082 ↗
29. A numerical investigation of repeating thermal bridges from metal fasteners in offsite manufactured timber frame closed panels for exterior walls
30. Combining hygrothermal and corrosion models to predict corrosion of metal fasteners embedded in wood10.1016/j.buildenv.2011.04.017 ↗
31. Effect of thermal bridge in light-frame wood wall10.15376/biores.18.1.367-381 ↗
32. Testing and FE modeling of lateral resistance of shear walls in light wood frame structures
33. Flexural properties of wooden nail friction welding of laminated timber10.15376/biores.18.1.1166-1176 ↗