journal article·2013-09

A Femur-Implant Model for the Prediction of Bone Remodeling Behavior Induced by Cementless Stem

He Gong, Lingyan Kong, Rui Zhang, Juan Fang, Meisheng Zhao

Journal of Bionic Engineering· Volume 10· Issue 3
Publisher page

Abstract

Bone remodeling simulation is an effective tool for the prediction of long-term effect of implant on the bone tissue, as well as the selection of an appropriate implant in terms of architecture and material. In this paper, a finite element model of proximal femur was developed to simulate the structures of internal trabecular and cortical bones by incorporating quantitative bone functional adaptation theory with finite element analysis. Cementless stems made of titanium, two types of Functionally Graded Material (FGM) and flexible ‘iso-elastic’ material as comparison were implanted in the structure of proximal femur respectively to simulate the bone remodeling behaviors of host bone. The distributions of bone density, von Mises stress, and interface shear stress were obtained. All the prosthetic stems had effects on the bone remodeling behaviors of proximal femur, but the degrees of stress shielding were different. The amount of bone loss caused by titanium implant was in agreement with the clinical observation. The FGM stems caused less bone loss than that of the titanium stem, in which FGM I stem (titanium richer at the top to more HAP/Col towards the bottom) could relieve stress shielding effectively, and the interface shear stresses were more evenly distributed in the model with FGM I stem in comparison with those in the models with FGM II (titanium and bioglass) and titanium stems. The numerical simulations in the present study provided theoretical basis for FGM as an appropriate material of femoral implant from a biomechanical point of view. The next steps are to fabricate FGM stem and to conduct animal experiments to investigate the effects of FGM stem on the remodeling behaviors using animal model.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. Mullender M G, Huiskes R. Proposal for the regulatory mechanism of Wolff’s law. Journal of Orthopaedic Research, 1995, 13, 503–512.10.1002/jor.1100130405 ↗
2. Huiskes R, Ruimerman R, Van Lenthe G H, Janssen J D. Effects of mechanical forces on maintenance and adaptation of form in trabecular bone. Nature, 2000, 405, 704–706.10.1038/35015116 ↗
3. Gong H, Zhu D, Gao J Z, Lv L W, Zhang X Z. An adaptation model for trabecular bone at different mechanical levels. Biomedical Engineering Online, 2010, 9, 32.10.1186/1475-925X-9-32 ↗
4. Ruimerman R, Van Rietbergen B, Hilbers P, Huiskes R. A 3-dimensional computer model to simulate trabecular bone metabolism. Biorheology, 2003, 40, 315–320.
5. Johnell O, Kanis J A. Epidemiology of osteoporotic fractures. Osteoporosis International, 2005, 16, s3–s7.10.1007/s00198-004-1702-6 ↗
6. Weinans H, Huiskes R, Grootenboer H J. Effects of fit and bonding characteristics of femoral stems on adaptive bone remodeling. Journal of Biomechanical Engineering–Transactions of the ASME, 1994, 116, 393–400.10.1115/1.2895789 ↗
7. Gong H, Wu W, Fang J, Dong X, Zhao M S, Guo T T. Effects of materials of cementless femoral stem on the functional adaptation of bone. Journal of Bionic Engineering, 2012, 9, 66–74.10.1016/S1672-6529(11)60098-X ↗
8. Zhu X H, Gong H, Gao B Z. The application of topology optimization on the quantitative description of the external shape of bone structure. Journal of Biomechanics, 2005, 38, 1612–1620.10.1016/j.jbiomech.2004.06.029 ↗
9. Weinans H, Huiskes R, Grootenboer H J. The behavior of adaptive bone-remodeling simulation models. Journal of Biomechanics, 1992, 25, 1425–1441.10.1016/0021-9290(92)90056-7 ↗
10. Bitsakos C, Kerner J, Fisher I, Amis A A. The effect of muscle loading on the simulation of bone remodelling in the proximal femur. Journal of Biomechanics, 2005, 38, 133–139.10.1016/j.jbiomech.2004.03.005 ↗
11. Mullender M G, Huiskes R, Weinans H. A physiological approach to the simulation of bone remodeling as a self-organizational control process. Journal of Biomechanics, 1994, 27, 1389–1394.10.1016/0021-9290(94)90049-3 ↗
12. Smith T S, Martin R B, Hubbard M, Bay B K. Surface remodeling of trabecular bone using a tissue level model. Journal of Orthopaedic Research, 1997, 15, 593–600.10.1002/jor.1100150416 ↗
13. Frost H M. Skeletal structural adaptations to mechanical usage (SATMU): 1. Redefining Wolff’s law: The bone modeling problem. Anatomical Record, 1990, 226, 403–413.10.1002/ar.1092260402 ↗
14. Frost H M. Skeletal structural adaptations to mechanical usage (SATMU): 2. Redefining Wolff’s law: the remodeling problem. Anatomical Record, 1990, 226, 414–422.10.1002/ar.1092260403 ↗
15. Carter D R. Mechanical loading histories and cortical bone remodeling. Calcified Tissue International, 1982, 36, 19–24.10.1007/BF02406129 ↗
16. Huiskes R, Weinans H, Grootenboer H J, Dalstra M, Fudala B, Slooff T J. Adaptive bone-remodeling theory applied to prosthetic design analysis. Journal of Biomechanics, 1987, 20, 1135–1150.10.1016/0021-9290(87)90030-3 ↗
17. Lian Z Q, Guan H, Ivanovski S, Loo Y C, Johnson N, Zhang H W. Finite element simulation of bone remodelling in the human mandible surrounding dental implant. Acta Mechanica, 2011, 217, 335–345.10.1007/s00707-010-0409-3 ↗
18. Zhu X H, Gong H, Bai X F, Wang F R. Application of subsectional relationship between elastic modulus and apparent density in the structural simulation of proximal femur. Chinese Journal of Biomedical Engineering, 2003, 22, 250–257. (in Chinese)
19. Lin C C, Huang L C, Shen P. Na2CaSi2O6-P2O5 based bioactive glasses. Part 1: Elasticity and structure. Journal of Non-Crystalline Solids, 2005, 40–42, 3195–3203.10.1016/j.jnoncrysol.2005.08.020 ↗
20. Lin D, Li Q, Li W, Swain M. Bone remodeling induced by dental implants of functionally graded materials. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2010, 92, 430–438.10.1002/jbm.b.31531 ↗
21. Hedia H S, Shabara M A N, El-Midany T T, Fouda N. A method of material optimization of cementless stem through functionally graded material. International Journal of Mechanics and Materials in Design, 2004, 1, 329–346.10.1007/s10999-005-3307-4 ↗
22. Gruen T A, McNeice G M, Amstutz H C. Models of failure of cemented stem-type femoral components, a radiographic analysis of loosening. Clinical Orthopaedics, 1979, 141, 17–27.
23. Brodner W, Bitzan P, Lomoschitz F, Krepler P, Jankovsky R, Lehr S, Kainberger F, Gottsauner-Wolf F. Changes in bone mineral density in the proximal femur after cementless total hip arthroplasty-a five-year longitudinal study. The Journal of Bone & Joint Surgery, 2004, 86, 20–26.10.1302/0301-620X.86B1.14637 ↗
24. Sumitomo N, Koritake K, Hattori T, Morikawa K, Niwa S, Sato K, Niinomi M. Experimental study on fracture fixation with low rigidity titanium alloy: Plate fixation of tibia fracture model in rabbit. Journal of materials science, 2008, 19, 1581–1586.
25. Niinomi M, Nakai M. Titanium-based biomaterials for preventing stress shielding between implant devices and bone. International Journals of Biomaterials, 2011, 836587.
26. Gong H, Wang L, Zheng D, Fan Y. The potential application of functionally graded material for proximal femoral nail antirotation device. Medical Hypotheses, 2012, 79, 415–417.10.1016/j.mehy.2012.06.013 ↗