Clinical device‐related article evaluation of morphology and functions of a foldable capsular vitreous body in the rabbit eye
Source abstract
Abstract
Abstract We previously proposed a new strategy to replace a vitreous body with a novel foldable capsular vitreous body (FCVB). In this study, the FCVB was designed to mimic natural vitreous morphology, and evaluate its physiological functions compared with traditional silicone oil substitutes, in an established rabbit model of proliferative vitreoretinopathy. We found that FCVB was a very good replacement for closely mimicking the morphology and restoring the physiological functions, such as the support, refraction, and cellular barriers, of the rabbit vitreous body. The study has provided us with a novel research and therapy strategy that could effectively mimic the morphology and physiological function of the rabbit vitreous body. © 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2011.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Retinal and Macular Surgery · Intraocular Surgery and Lenses · Retinal Development and Disorders
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. Green WR · 2006 · 1921
2. 10.1038/eye.2008.2110.1038/eye.2008.21 ↗
3. 10.1136/bjo.87.3.31810.1136/bjo.87.3.318 ↗
4. Long‐term results of pars plana vitrectomy and silicone oil for complications of diabetic retinopathy10.1177/112067219400400109 ↗
5. 10.1016/S0039-6257(98)00023-X10.1016/S0039-6257(98)00023-X ↗
6. 10.1016/j.ophtha.2006.05.03910.1016/j.ophtha.2006.05.039 ↗
7. 10.1097/00006982-200306000-0001310.1097/00006982-200306000-00013 ↗
8. 10.1001/archopht.1962.0096003059400510.1001/archopht.1962.00960030594005 ↗
9. 10.1001/archopht.1992.0108018004202710.1001/archopht.1992.01080180042027 ↗
10. 10.1016/S0161-6420(98)99023-610.1016/S0161-6420(98)99023-6 ↗
11. 10.1007/s00417-009-1155-x10.1007/s00417-009-1155-x ↗
12. 10.1055/s-0029-124529510.1055/s-0029-1245295 ↗
13. 10.1136/bjo.2004.05718210.1136/bjo.2004.057182 ↗
14. 10.1167/iovs.06-094110.1167/iovs.06-0941 ↗
15. 10.1007/s10856-010-4092-710.1007/s10856-010-4092-7 ↗
16. 10.1002/(SICI)1097-4636(19980315)39:4<650::AID-JBM21>3.0.CO;2-910.1002/(SICI)1097-4636(19980315)39:4<650::AID-JBM21>3.0.CO;2-9 ↗
17. Artificial vitreous replacements
18. Vitrectomy: In search of the ideal vitreous replacement
19. 10.1038/sj.eye.670287510.1038/sj.eye.6702875 ↗
20. 10.1111/j.1525-1594.2010.01006.x10.1111/j.1525-1594.2010.01006.x ↗
21. 10.1167/iovs.08-280210.1167/iovs.08-2802 ↗
22. 10.1167/iovs.09-413410.1167/iovs.09-4134 ↗
23. GaoQ. A novel method andomould for foldable capsular vitreous body China patent No. 200810199177.3 2008.
24. A new model of proliferative vitreoretinopathy
25. 10.1097/00006982-198808010-0000510.1097/00006982-198808010-00005 ↗
26. 10.1016/S1350-9462(97)00007-410.1016/S1350-9462(97)00007-4 ↗
27. 10.1097/00006982-200204000-0000310.1097/00006982-200204000-00003 ↗
28. Evaluation of the flexibility, efficacy, and safety of a foldable capsular vitreous body in the treatment of severe retinal detachment