Abstract Regular 3D periodic porous Ti‐6Al‐4V structures intended to reduce the effects of stress shielding in load‐bearing bone replacement implants (e.g., hip stems) were fabricated over a range of relative densities (0.17–0.40) and pore sizes (∼500–1500 μm) using selective electron beam melting (EBM). Compression‐compression fatigue testing (15 Hz,R= 0.1) resulted in normalized fatigue strengths at 106cycles ranging from 0.15 to 0.25, which is lower than the expected value of 0.4 for solid material of the same acicular α microstructure. The three possible reasons for this reduced fatigue lifetime are stress concentrations from closed porosity observed within struts, stress concentrations from observed strut surface features (sintered particles and texture lines), and microstructure (either acicular α or martensite) with less than optimal high‐cycle fatigue resistance. © 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2011.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties · Additive Manufacturing Materials and Processes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (40)

Show source-provided references
1. Engh CA · 1985
2. Producing and avoiding stress shielding: Laboratory and clinical observations of noncemented total hip arthroplasty10.1097/00003086-199201000-00010 ↗
3. Im G‐I · 2002 · 177
4. 10.1016/S0142-9612(97)00146-410.1016/S0142-9612(97)00146-4 ↗
5. 10.4028/www.scientific.net/KEM.99-100.30910.4028/www.scientific.net/KEM.99-100.309 ↗
6. 10.3109/1745367930899460210.3109/17453679308994602 ↗
7. 10.1002/adem.20040557610.1002/adem.200405576 ↗
8. Kupp D · 2002 · 61
9. 10.1016/j.biomaterials.2005.12.00210.1016/j.biomaterials.2005.12.002 ↗
10. Davis JR · 2003
11. Ashby MF · 2000
12. 10.1146/annurev.matsci.30.1.19110.1146/annurev.matsci.30.1.191 ↗
13. 10.1016/S1359-6454(99)00097-X10.1016/S1359-6454(99)00097-X ↗
14. 10.1016/j.ijfatigue.2005.06.04410.1016/j.ijfatigue.2005.06.044 ↗
15. 10.1016/S1359-6454(97)00148-110.1016/S1359-6454(97)00148-1 ↗
16. 10.1016/S0921-5093(99)00147-110.1016/S0921-5093(99)00147-1 ↗
17. Yokobori T · 1964
18. 10.4028/www.scientific.net/KEM.284-286.26310.4028/www.scientific.net/KEM.284-286.263 ↗
19. 10.1002/jbm.82019060910.1002/jbm.820190609 ↗
20. 10.1002/jbm.82018090810.1002/jbm.820180908 ↗
21. 10.1002/jbm.82018050410.1002/jbm.820180504 ↗
22. 10.1002/jbm.82022040410.1002/jbm.820220404 ↗
23. Porous‐surfaced metallic implants for orthopedic applications10.1002/j.1097-4636.1987.tb00003.x ↗
24. Rudinger K · 1985 · 2123
25. Turner AC · 2009 · 129
26. 10.1002/adem.20080013710.1002/adem.200800137 ↗
27. 10.1016/j.msea.2008.04.00210.1016/j.msea.2008.04.002 ↗
28. 10.1016/j.msec.2007.04.02210.1016/j.msec.2007.04.022 ↗
29. 10.1002/adem.20070002510.1002/adem.200700025 ↗
30. 10.1016/j.matlet.2008.10.06510.1016/j.matlet.2008.10.065 ↗
31. Lee YL · 2005
32. Ackelid U · 2009 · 2711
33. Hrabe N · 2010 · 250
34. 10.1016/j.matchar.2008.07.00610.1016/j.matchar.2008.07.006 ↗
35. 10.1016/j.jmbbm.2008.05.00410.1016/j.jmbbm.2008.05.004 ↗
36. Donachie MJ · 1989
37. Welsch G · 1994
38. Boyer RR · 1987 · 149
39. Lutjering G · 1985 · 2065
40. Peters M · 1981 · 1777