journal article·2018-07Open access

The effect of ventricular assist device‐associated biomaterials on human blood leukocytes

Gemma Radley, Ina Laura Pieper, Catherine A. Thornton

Abstract

Abstract Ventricular assist devices (VADs) are an effective bridging or destination therapy for patients with advanced stage heart failure. These devices remain susceptible to adverse events including infection, bleeding, and thrombus; events linked to the foreign body response. Therefore, the biocompatibility of all biomaterials used is crucial to the success of medical devices. Biomaterials common in VADs—DLC: diamond‐like carbon coated stainless steel; Sap: single‐crystal sapphire; SiN: silicon nitride; Ti: titanium alloy; and ZTA: zirconia‐toughened alumina—were tested for their biocompatibility through incubation with whole human blood for 2 h with mild agitation. Blood was then removed and used for: complete cell counts; leukocyte activation and death, and the production of key inflammatory cytokines. All were compared to time 0 and an un‐exposed 2 h sample. Monocyte numbers were lower after exposure to DLC, SiN, and ZTA and monocytes showed evidence of activation with DLC, Sap, and SiN. Neutrophils and lymphocytes were unaffected. This approach allows comprehensive analysis of the potential blood damaging effects of biomaterials. Monocyte activation by DLC, Sap, ZTA, and SiN warrants further investigation linking effects on this cell type to unfavorable inflammatory/thrombogenic responses to VADs and other blood handling devices. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1730–1738, 2018.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Mechanical Circulatory Support Devices · Cardiac Structural Anomalies and Repair · Fuel Cells and Related Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute of Life Science, Swansea University Medical School Swansea Wales UK

Calon Cardio ‐ Technology Ltd., Institute of Life Science Swansea Wales UK

Funding

St David's Medical Foundation

References (61)

Show source-provided references
1. 10.1054/jcaf.2002.3294410.1054/jcaf.2002.32944 ↗
2. 10.1016/j.healun.2010.01.01110.1016/j.healun.2010.01.011 ↗
3. 10.1163/15685620074418310.1163/156856200744183 ↗
4. Dietschweiler C · 2008
5. Adhesion of platelets to surface‐bound fibrinogen under flow10.1182/blood.V88.8.2967.bloodjournal8882967 ↗
6. 10.3109/09537104.2015.106488110.3109/09537104.2015.1064881 ↗
7. 10.1053/pcad.2000.719110.1053/pcad.2000.7191 ↗
8. 10.1016/j.biomaterials.2004.01.02310.1016/j.biomaterials.2004.01.023 ↗
9. 10.1002/(SICI)1097-4636(19990305)44:3<289::AID-JBM7>3.0.CO;2-O10.1002/(SICI)1097-4636(19990305)44:3<289::AID-JBM7>3.0.CO;2-O ↗
10. 10.1016/S0142-9612(02)00359-910.1016/S0142-9612(02)00359-9 ↗
11. 10.1002/jbm.a.3186310.1002/jbm.a.31863 ↗
12. 10.1073/pnas.11046319710.1073/pnas.110463197 ↗
13. 10.1111/j.1525-1594.2007.00351.x10.1111/j.1525-1594.2007.00351.x ↗
14. 10.1111/aor.1220010.1111/aor.12200 ↗
15. 10.1097/MAT.0b013e3181b235af10.1097/MAT.0b013e3181b235af ↗
16. 10.1016/S0140-6736(98)10359-810.1016/S0140-6736(98)10359-8 ↗
17. 10.1016/j.athoracsur.2008.01.05010.1016/j.athoracsur.2008.01.050 ↗
18. 10.1046/j.1538-7836.2003.00089.x10.1046/j.1538-7836.2003.00089.x ↗
19. 10.1016/j.healun.2014.01.00410.1016/j.healun.2014.01.004 ↗
20. Ufukerbulut D · 2010 · 207
21. 10.1177/088532821243961510.1177/0885328212439615 ↗
22. 10.1055/s-0037-161463010.1055/s-0037-1614630 ↗
23. 10.1016/S0003-4975(00)02639-410.1016/S0003-4975(00)02639-4 ↗
24. 10.1111/aor.1215810.1111/aor.12158 ↗
25. 10.1016/j.jtcvs.2011.01.01110.1016/j.jtcvs.2011.01.011 ↗
26. 10.1002/jbm.b.3114710.1002/jbm.b.31147 ↗
27. 10.1016/j.mri.2007.03.02010.1016/j.mri.2007.03.020 ↗
28. 10.1016/j.msea.2009.09.06410.1016/j.msea.2009.09.064 ↗
29. 10.1016/S0142-9612(99)00007-110.1016/S0142-9612(99)00007-1 ↗
30. 10.1002/jbm.b.3129110.1002/jbm.b.31291 ↗
31. 10.1016/j.surfcoat.2005.07.07710.1016/j.surfcoat.2005.07.077 ↗
32. 10.22203/eCM.v005a0210.22203/eCM.v005a02 ↗
33. 10.1016/j.smim.2007.11.00410.1016/j.smim.2007.11.004 ↗
34. 10.1160/TH13-03-022010.1160/TH13-03-0220 ↗
35. 10.1111/j.1423-0410.2009.01249.x10.1111/j.1423-0410.2009.01249.x ↗
36. 10.1002/cyto.a.2287410.1002/cyto.a.22874 ↗
37. 10.1080/0953710977711310.1080/09537109777113 ↗
38. 10.1111/j.1365-3083.1992.tb02953.x10.1111/j.1365-3083.1992.tb02953.x ↗
39. 10.1016/j.jim.2008.10.00510.1016/j.jim.2008.10.005 ↗
40. 10.1016/j.ajpath.2013.02.02210.1016/j.ajpath.2013.02.022 ↗
41. 10.1177/088532821245468910.1177/0885328212454689 ↗
42. 10.1067/mlc.2001.11467710.1067/mlc.2001.114677 ↗
43. ISO/IEC Biological evaluation of medical devices—part 4: selection of tests for interactions with blood2009;10993‐4.
44. 10.1084/jem.2011232210.1084/jem.20112322 ↗
45. 10.1016/S0041-1345(00)02754-810.1016/S0041-1345(00)02754-8 ↗
46. 10.1067/mlc.2001.11147010.1067/mlc.2001.111470 ↗
47. 10.1016/j.biomaterials.2003.10.01110.1016/j.biomaterials.2003.10.011 ↗
48. 10.1002/jbm.a.3036610.1002/jbm.a.30366 ↗
49. 10.1016/S0142-9612(03)00097-810.1016/S0142-9612(03)00097-8 ↗
50. CapelloWN D'AnthonioJA FeinbergJR ManleyMT. Alternative bearing surfaces: alumina ceramic bearings for total hip arthroplasty. In: Bioceramics and Alternative Bearings in Joint Arthroplasty. Darmstadt: Steinkopff;2005. pp87–94.10.1007/3-7985-1540-9_14 ↗
51. Biocompatibility of surgical‐grade dense polycrystalline alumina
52. 10.1002/(SICI)1097-4636(19970905)36:3<381::AID-JBM12>3.0.CO;2-H10.1002/(SICI)1097-4636(19970905)36:3<381::AID-JBM12>3.0.CO;2-H ↗
53. 10.1002/(SICI)1097-4636(199804)40:1<24::AID-JBM3>3.0.CO;2-T10.1002/(SICI)1097-4636(199804)40:1<24::AID-JBM3>3.0.CO;2-T ↗
54. The role of monocytes in thrombotic disorders. Insights from tissue factor, monocyte‐platelet aggregates and novel mechanisms
55. 10.1016/j.ejcts.2010.06.01510.1016/j.ejcts.2010.06.015 ↗
56. 10.1007/978-1-4613-2769-1_910.1007/978-1-4613-2769-1_9 ↗
57. 10.1016/S0142-9612(01)00182-X10.1016/S0142-9612(01)00182-X ↗
58. 10.1590/2446-4740.0361610.1590/2446-4740.03616 ↗
59. 10.1016/S0008-6363(99)00262-X10.1016/S0008-6363(99)00262-X ↗
60. 10.1007/s10741-016-9533-z10.1007/s10741-016-9533-z ↗
61. 10.1002/jbm.b.3336610.1002/jbm.b.33366 ↗