Frequency effect in fretting wear of Co‐28Cr‐6Mo versus Ti‐6Al‐4V implant alloys
Source abstract
Abstract
Abstract A piezo‐electrically driven fretting testing device has been constructed and fretting release and release rates have been determined with highest accuracy, using a radiotracer technique. First results on the fretting release and release rate of titanium alloy fretting pads against cobalt‐chrome alloy fatigue specimens are reported. The frequency dependency of fretting release has been determined between 1 and 8 Hz and shows higher release rates for low frequencies, thus indicating that accelerated testing of materials and components of artificial joints must be analyzed extremely carefully. The present experiments under simple conditions present a base‐line study for step‐wise applying more complex and realistic testing conditions and for using radiotracer methods to quantify fretting release in simulated testing of artificial hip‐ and knee‐prostheses. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Mechanical stress and fatigue analysis · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (52)
Show source-provided references
1. HerbertsP MalchauH GarellickG.The Swedish National Hip Arthroplasty Register Annual Report 2003 Department of Orthopaedics Sahlgrenska University Hospital 2004.
2. ZuckermannJD CavalloRJ KummerFJ.A review of the use of modularity in total shoulder arthroplasty. In:MarloweDE ParrJE MayorMB editors.Modularity in Orthopedic Implants ASTM STP 1301.West Conshohocken:ASTM;1997. p5–18.10.1520/STP12017S ↗
3. KraayMJ GoldbergCM BrownSA MerrittK.Retrieval analysis of Ti‐6Al‐4V Miller‐Galante total knee replacements. In:BrownSA LemonsJE editors.Medical Applications of Titanium and Its Alloys: The Material and Biological Issues ASTM STP 1272.West Conshohocken:ASTM;1996. p409–416.10.1520/STP16095S ↗
4. 10.1179/imr.1992.37.1.7710.1179/imr.1992.37.1.77 ↗
5. 10.1016/0043-1648(94)90272-010.1016/0043-1648(94)90272-0 ↗
6. ClarkeIC CampellP KossovskyN.Debris‐mediated osteolysis—A cascade phenomenon involving motion wear particulates macrophage induction and bone lysis. In:St. JohnKR editor.Particulate Debris from Medical Implants: Mechanisms of Formation and Biological Consequences ASTM STP 1144.Philadelphia:ASTM;1992. p7–26.10.1520/STP14848S ↗
7. 10.1097/00002281-199204000-0001210.1097/00002281-199204000-00012 ↗
8. 10.1016/0142-9612(94)90170-810.1016/0142-9612(94)90170-8 ↗
9. 10.2106/00004623-199409000-0000910.2106/00004623-199409000-00009 ↗
10. 10.1002/jbm.82027121010.1002/jbm.820271210 ↗
11. The tradeoffs associated with modular hip prostheses
12. BhambriSK GilbertsonLN.Characterization and quantification of fretting particulates generated in ceramic/metal and metal/metal modular head/taper system. In:KambicHE TokoboriAT Jr editors.Biomaterials' Mechanical Properties. ASTM STP 1173.Philadelphia:ASTM;1994. p111–126.10.1520/STP18098S ↗
13. 10.1002/(SICI)1097-4636(199602)30:2<181::AID-JBM7>3.0.CO;2-N10.1002/(SICI)1097-4636(199602)30:2<181::AID-JBM7>3.0.CO;2-N ↗
14. FlemmingCAC BrownSA PayerJH.Mechanical testing for fretting corrosion of modular total hip tapers. In:KambicHE YokoboriAT Jr. editors.Biomaterials' Mechanical Properties. ASTM STP 1173.Philadelphia:ASTM;1994. p156–166.10.1520/STP18102S ↗
15. 10.1002/(SICI)1097-4636(199705)35:2<207::AID-JBM9>3.0.CO;2-R10.1002/(SICI)1097-4636(199705)35:2<207::AID-JBM9>3.0.CO;2-R ↗
16. 10.1002/jbm.82015040410.1002/jbm.820150404 ↗
17. 10.1002/jor.110006041510.1002/jor.1100060415 ↗
18. 10.1002/jbm.82029071210.1002/jbm.820290712 ↗
19. 10.3109/1073119830911881410.3109/10731198309118814 ↗
20. KovacsP DavidsonJA DaigleK.Correlation between the metal ion concentration and the fretting wear volume of orthopaedic implant metals. In:St. JohnKR editor.Particulate Debris from Medical Implants: Mechanisms of Formation and Biological Consequences. ASTM STP 1144.Philadelphia:ASTM;1992. p160–176.10.1520/STP14863S ↗
21. 10.1002/jor.110011061310.1002/jor.1100110613 ↗
22. 10.1002/1097-4636(2001)58:2<156::AID-JBM1002>3.0.CO;2-H10.1002/1097-4636(2001)58:2<156::AID-JBM1002>3.0.CO;2-H ↗
23. 10.1016/S0043-1648(03)00230-810.1016/S0043-1648(03)00230-8 ↗
24. 10.1016/0168-583X(90)90330-W10.1016/0168-583X(90)90330-W ↗
25. 10.1016/S0375-9474(01)01586-X10.1016/S0375-9474(01)01586-X ↗
26. Surface layer activation for measuring fretting wear
27. 10.1016/0301-679X(95)00048-910.1016/0301-679X(95)00048-9 ↗
28. The quantification of microscopic wear amounts of steel surfaces with thin layer activation
29. 10.1115/1.283389410.1115/1.2833894 ↗
30. ASTM F1875–98 Standard Practice for Fretting Corrosion Testing of Modular Implant Interfaces: Hip Femoral Head‐bore and Cone Taper Interface 2004.
31. ISO 7206 Implants for Surgery—Partial and Total Hip Joint Prostheses ISO;2002.
32. ASTM F897–02 Standard Test Method for Measuring Fretting Corrosion of Osteosynthesis Plates and Screws;1998.
33. Fretting corrosion of mild steel in air and in nitrogen10.1115/1.4010939 ↗
34. 10.1016/0043-1648(88)90134-210.1016/0043-1648(88)90134-2 ↗
35. 10.1016/0301-679X(89)90081-910.1016/0301-679X(89)90081-9 ↗
36. VincentL BerthierY GodetM.Testing methods in fretting fatigue: A critical appraisal. In:AttiaHM WaterhouseRB editors.Standardization of Fretting Fatigue Test Methods and Equipment. ASTM STP 1159.Philadelphia:ASTM;1992. p33–48.10.1520/STP25812S ↗
37. 10.1007/BF0266736710.1007/BF02667367 ↗
38. 10.1080/1040200930898315810.1080/10402009308983158 ↗
39. 10.1023/A:102236841445510.1023/A:1022368414455 ↗
40. BrownSA AberaA D'OnofricoM FlemmingC.Effects of neck extension coverage and frequency on the fretting corrosion of modular THR bore and cone interface. In:MarloweDE ParrJE MayorMB editors.Modularity in Orthopaedic Implants. ASTM STP 1301.West Conshohocken:ASTM;1997. p189–198.10.1520/STP12032S ↗
41. 10.1299/jsme1958.12.130010.1299/jsme1958.12.1300 ↗
42. 10.1016/0043-1648(72)90409-710.1016/0043-1648(72)90409-7 ↗
43. 10.1016/0043-1648(86)90149-310.1016/0043-1648(86)90149-3 ↗
44. 10.1016/S0301-679X(99)00099-710.1016/S0301-679X(99)00099-7 ↗
45. 10.1016/S0021-9290(00)00058-010.1016/S0021-9290(00)00058-0 ↗
46. Boyer HE · 1986 · 431
47. CortezR MallS CalcaterraJR.Interaction of high‐cycle and low‐cycle fatigue on fretting behavior of Ti‐6–4. In:HoeppnerDW ChandrasekaranV ElliottCB editors.Fretting Fatigue: Current Technology and Practices. ASTM STP 1367.West Conshohocken:ASTM;2000. p183–198.10.1520/STP14729S ↗
48. 10.1016/0043-1648(74)90114-810.1016/0043-1648(74)90114-8 ↗
49. 10.1016/S0142-9612(97)00146-410.1016/S0142-9612(97)00146-4 ↗
50. 10.1016/S0043-1648(99)00372-510.1016/S0043-1648(99)00372-5 ↗
51. BrownSA MerrittK.Fretting corrosion of plates and screws: An in vitro test method. In:FrakerAC GriffinCD editors.Corrosion and Degradation of Implant Materials: Second Symposium ASTM STP 859.Philadelphia:ASTM;1985. p105–116.10.1520/STP33245S ↗
52. 10.1016/S0142-9612(98)00217-810.1016/S0142-9612(98)00217-8 ↗