journal article·2025-04Open access

Analytical Modeling and Validation of Radial Stiffness in Zigzag‐Shaped Stents: Experimental and Numerical Approaches

Moshe Brand, Nadav Sharon

Abstract

ABSTRACT Stents and stent grafts (SGs) are used in many endovascular procedures. Clinical studies have revealed that radial stiffness (RS) in stents increases pressure on the artery wall, which can cause restenosis and, in some cases, require repeated intervention. This study aimed to validate an analytical model for calculating the RS of stents and SG with a zigzag‐shaped structure. Four commercial SGs with varying geometric dimensions and material properties were selected. The analytical model's RS calculations were compared with experimental measurements and numerical model predictions. An excellent agreement was observed between the RS values measured in the experimental system and those calculated in the analytical model, with an average difference of 2.4% ± 3.3%. Validation of the analytical model enables the design of stents with a desired RS that is optimally suited to a specific patient.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Coronary Interventions and Diagnostics · Aortic aneurysm repair treatments · Peripheral Artery Disease Management

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical Engineering and Mechatronics Ariel University Ariel Israel

School of Mechanical Engineering Tel Aviv University Tel Aviv Israel

References (47)

Show source-provided references
1. 10.1016/j.jvs.2014.08.07710.1016/j.jvs.2014.08.077 ↗
2. 10.1007/s11517‐016‐1574‐x10.1007/s11517‐016‐1574‐x ↗
3. 10.1016/j.euromechflu.2012.03.01010.1016/j.euromechflu.2012.03.010 ↗
4. 10.1006/jtbi.2000.214310.1006/jtbi.2000.2143 ↗
5. Mechanical Behavior of Fully Expanded Commercially Available Endovascular Coronary Stents
6. 10.1016/j.compbiomed.2014.06.01510.1016/j.compbiomed.2014.06.015 ↗
7. 10.1016/j.jvs.2012.12.03510.1016/j.jvs.2012.12.035 ↗
8. 10.1098/rsos.23056310.1098/rsos.230563 ↗
9. 10.1002/jbm.b.3102810.1002/jbm.b.31028 ↗
10. 10.1016/j.ejvs.2011.06.01210.1016/j.ejvs.2011.06.012 ↗
11. 10.1583/08‐2370.110.1583/08‐2370.1 ↗
12. Brand M. · 2008 · 103
13. 10.1115/1.187119410.1115/1.1871194 ↗
14. Leybovitch E. · 2016 · 76
15. 10.1016/j.jbiomech.2016.03.02310.1016/j.jbiomech.2016.03.023 ↗
16. 10.1186/s12938‐016‐0135‐810.1186/s12938‐016‐0135‐8 ↗
17. 10.1016/j.matdes.2023.11174810.1016/j.matdes.2023.111748 ↗
18. Karanasiou S. G. · 2018 · 4567
19. 10.1142/S021951942250038510.1142/S0219519422500385 ↗
20. 10.1016/j.cjmeam.2022.10002010.1016/j.cjmeam.2022.100020 ↗
21. 10.1002/app.5224210.1002/app.52242 ↗
22. 10.1109/BIBE.2017.00-1110.1109/BIBE.2017.00-11 ↗
23. 10.1016/j.matdes.2013.03.01210.1016/j.matdes.2013.03.012 ↗
24. 10.1007/s13239‐021‐00597‐w10.1007/s13239‐021‐00597‐w ↗
25. 10.1016/j.jmbbm.2019.10361010.1016/j.jmbbm.2019.103610 ↗
26. 10.1080/10255842.2013.87342010.1080/10255842.2013.873420 ↗
27. 10.3233/BME‐17171410.3233/BME‐171714 ↗
28. 10.1016/j.jbiomech.2020.10985610.1016/j.jbiomech.2020.109856 ↗
29. 10.1007/s00419‐022‐02307‐x10.1007/s00419‐022‐02307‐x ↗
30. 10.1016/j.jmbbm.2017.02.00610.1016/j.jmbbm.2017.02.006 ↗
31. 10.1007/s10439‐019‐02322‐010.1007/s10439‐019‐02322‐0 ↗
32. 10.1016/S1386‐5056(97)01266‐510.1016/S1386‐5056(97)01266‐5 ↗
33. 10.1002/jab.77004011110.1002/jab.770040111 ↗
34. Jie Y. · 2010 · 1435
35. 10.1016/j.msec.2014.05.05710.1016/j.msec.2014.05.057 ↗
36. 10.3389/fbioe.2020.0073610.3389/fbioe.2020.00736 ↗
37. Brand M. · 2015
38. 10.1007/s13239‐015‐0235‐910.1007/s13239‐015‐0235‐9 ↗
39. 10.1016/J.MATDES.2021.11014410.1016/J.MATDES.2021.110144 ↗
40. 10.1016/J.JIEC.2014.05.04510.1016/J.JIEC.2014.05.045 ↗
41. 10.1115/1.183536210.1115/1.1835362 ↗
42. Khan M. F. · 2007
43. 10.4103/0975‐3583.10272510.4103/0975‐3583.102725 ↗
44. 10.1007/s44164‐022‐00009‐w10.1007/s44164‐022‐00009‐w ↗
45. Robertson S. W. · 1998
46. 10.1179/1743280411Y.000000000910.1179/1743280411Y.0000000009 ↗
47. Understanding the Mechanical Properties of Self‐Expandable Stents: A Key to Successful Product Development