Temperature evaluation during PMMA screw augmentation in osteoporotic bone—An in vitro study about the risk of thermal necrosis in human femoral heads
Source abstract
Abstract
Abstract The use of polymethylmethacrylate (PMMA) bone cement to augment hip screws reduces cut‐out risk but is associated with an exothermic reaction. This in vitro investigation evaluated the risk of thermal necrosis when augmenting the implant purchase with PMMA. A pilot study analyzed the effects of different PMMA layer thicknesses on temperatures around an implant. The main study used either 3.0 or 6.0 cc PMMA for hip screw augmentation in human femoral heads. The risk of thermal necrosis was estimated according to critical values reported in literature. Highest temperatures were measured inside the PMMA with a significant drop of average maximum temperatures from the center of the PMMA to the PMMA/bone interface. Risk of thermal necrosis exists with PMMA layer thicknesses greater than 5.0 mm. In the main study, we found no risk of thermal necrosis at the PMMA/bone interface or in the surrounding bone, neither with 3.0 nor 6.0 cc PMMA. The results of the two studies were consistent regarding average peak temperatures related to associated cement layer thicknesses. The results of this in vitro study reduce objections concerning the risk of thermal necrosis when augmenting cancellous bone around hip screws with up to 6.0 cc PMMA. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 2009
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Hip and Femur Fractures · Hip disorders and treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. 10.1302/0301-620X.72B1.229879010.1302/0301-620X.72B1.2298790 ↗
2. Mechanical failure of Dynamic Hip Screw (DHS) fixation in intertrochanteric fracture of the femur
3. 10.1002/jor.2029910.1002/jor.20299 ↗
4. 10.1007/BF0041708310.1007/BF00417083 ↗
5. Evaluation of the effects of implant materials and designs on thermal necrosis of bone in cemented hip arthroplasty
6. 10.1115/1.157185310.1115/1.1571853 ↗
7. 10.1002/jbm.1033410.1002/jbm.10334 ↗
8. Conduction analysis of cement interface temperature in total knee arthroplasty
9. Kuehn KD · 2001 · 148
10. 10.1002/jor.110017061410.1002/jor.1100170614 ↗
11. 10.1016/0022-3913(83)90174-910.1016/0022-3913(83)90174-9 ↗
12. 10.1016/S0021-9290(03)00012-510.1016/S0021-9290(03)00012-5 ↗
13. 10.1016/0021-9290(80)90014-710.1016/0021-9290(80)90014-7 ↗
14. 10.1002/jbm.82015011210.1002/jbm.820150112 ↗
15. 10.1097/01.BRS.0000076829.54235.9F10.1097/01.BRS.0000076829.54235.9F ↗
16. 10.1016/S8756-3282(99)00127-110.1016/S8756-3282(99)00127-1 ↗
17. 10.1007/BF0029841210.1007/BF00298412 ↗
18. 10.1023/A:100889871292910.1023/A:1008898712929 ↗
19. Thermal aspects of the use of polymethylmethacrylate in large metaphyseal defects in bone. A clinical review and laboratory study
20. 10.2106/00004623-197759010-0001410.2106/00004623-197759010-00014 ↗
21. 10.1007/BF0038971310.1007/BF00389713 ↗
22. Heat and bone tissue. An experimental investigation of the thermal properties of bone and threshold levels for thermal injury
23. Augmentation of osteoporotic bone: Effect of pulsed jet‐lavage on injection forces, cement distribution, and push‐out strength of implants
24. 10.1016/j.jbiomech.2004.03.00210.1016/j.jbiomech.2004.03.002 ↗
25. Temperatures measured during reaming of the femoral neck and head. A preliminary report10.1097/00003086-198904000-00023 ↗
26. 10.1016/0020-1383(95)93499-810.1016/0020-1383(95)93499-8 ↗
27. 10.1080/1745367061004598410.1080/17453670610045984 ↗