journal article·2019-07

Bone cement modeling for percutaneous vertebroplasty

Nicole Lepoutre, Laurence Meylheuc, Gabriela Iuliana Bara, Laurent Barbé, Bernard Bayle

Publisher page

Abstract

Abstract Vertebroplasty procedures provide a significant benefit for patients suffering from vertebral fractures. In order to address current issues of vertebroplasty procedures, an injection device able to control the bone cement viscosity has been developed. In addition, this device allows to protect the practitioner by removing him/her from the X‐rays area. In this context, a study is first proposed to quantify the bone cement viscosity during its polymerization reaction on a rotational rheometer. These experimental measurements have led to the identification of a complete behavior law that takes into account the simultaneous effects of shear rate, time, and temperature. Based on this preliminary study, this article finally aims to prove the ability of estimating the viscosity of the flowing bone cement on the developed injection system. A final set of experiments validates that the injection device dedicated to vertebroplasty procedures can control the flowing bone cement viscosity by acting on the temperature. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1504–1515, 2019.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Spinal Fractures and Fixation Techniques · Medical Imaging and Analysis · Spine and Intervertebral Disc Pathology

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

ICube – University of Strasbourg – UMR 7357 CNRS – INSA Strasbourg 1 place de l'Hôpital, 67091, Strasbourg France

References (36)

Show source-provided references
1. 10.1007/s00270-005-0146-510.1007/s00270-005-0146-5 ↗
2. Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty
3. 10.1016/S0140-6736(16)31341-110.1016/S0140-6736(16)31341-1 ↗
4. 10.1007/s00270-006-0146-010.1007/s00270-006-0146-0 ↗
5. 10.1016/S1051-0443(07)61770-910.1016/S1051-0443(07)61770-9 ↗
6. 10.1007/s00264-014-2525-510.1007/s00264-014-2525-5 ↗
7. 10.1007/s00586000018210.1007/s005860000182 ↗
8. 10.1016/j.spinee.2007.04.00410.1016/j.spinee.2007.04.004 ↗
9. BaroudG.Method and Apparatus for Monitoring and/or Controlling the Curing of Cements used in Medical Procedures. Patent US 20140009173 A1 2014.
10. NLepoutre GIBara LMeylheuc FSchmitt LBarbéandBBayle Design and control of a thermal device for bone cement injection. In: 2016 6th IEEE International Conference on Biomedical Robotics and Biomechatronics (BioRob); 2016. pp. 508–513.10.1109/BIOROB.2016.7523677 ↗
11. NLepoutre RAleluia Porto LMeylheuc GIBara FSchmitt LBarbéandBBayle. Robotically assisted injection of orthopedic cement: System design control and modeling. In: 2016 European Control Conference (ECC); 2016. pp. 2127–2132.10.1109/ECC.2016.7810606 ↗
12. 10.1016/j.jmbbm.2016.08.00910.1016/j.jmbbm.2016.08.009 ↗
13. 10.1007/s10973-011-1508-710.1007/s10973-011-1508-7 ↗
14. 10.1002/jbm.b.3139610.1002/jbm.b.31396 ↗
15. 10.1002/jbm.b.2000910.1002/jbm.b.20009 ↗
16. 10.1002/jbm.82016030510.1002/jbm.820160305 ↗
17. 10.1002/jbm.1012710.1002/jbm.10127 ↗
18. 10.1016/S0142-9612(01)00047-310.1016/S0142-9612(01)00047-3 ↗
19. 10.1007/s10856-007-0125-210.1007/s10856-007-0125-2 ↗
20. 10.1002/jbm.b.3065710.1002/jbm.b.30657 ↗
21. 10.1016/j.jmbbm.2013.06.00710.1016/j.jmbbm.2013.06.007 ↗
22. 10.1016/j.mechrescom.2012.12.01010.1016/j.mechrescom.2012.12.010 ↗
23. 10.1002/jbm.b.3183510.1002/jbm.b.31835 ↗
24. 10.1016/j.medengphy.2016.09.01510.1016/j.medengphy.2016.09.015 ↗
25. 10.1016/S0142-9612(03)00086-310.1016/S0142-9612(03)00086-3 ↗
26. Ueber die Geschwindigkeitsfunktion der Viskosität disperser Systeme. II
27. 10.1122/1.54927610.1122/1.549276 ↗
28. Yasuda K · 1979
29. 10.1002/app.2925310.1002/app.29253 ↗
30. Bird RB · 1987
31. 10.3139/978344641281110.3139/9783446412811 ↗
32. 10.1007/s00586-009-1037-210.1007/s00586-009-1037-2 ↗
33. 10.1007/978-3-642-41536-410.1007/978-3-642-41536-4 ↗
34. 10.1007/BF0065692710.1007/BF00656927 ↗
35. 10.1016/j.compbiomed.2007.10.00910.1016/j.compbiomed.2007.10.009 ↗
36. Osswald T · 201410.3139/9781569905234 ↗