Detailed characterization of hyaluronan using aqueous size exclusion chromatography with triple detection and multiangle light scattering detection
Source abstract
Abstract
Abstract Hyaluronan (HA) has attracted great interest and attention from ophthalmic surgical and eye care companies owing to its unique properties. A more complete understanding of HA biopolymers has, therefore, become increasingly critical as thorough characterization of raw materials helps promote product quality and process control. Often, such detailed information requires the use of a combination of analytical techniques. In this study, we compared size exclusion chromatography (SEC) with online multiangle light scattering (SEC‐MALS) and SEC with triple detection (SEC‐TD) experiments for HA analysis. Three lots of commercially available eye drop grade HA were characterized by SEC‐MALS and SEC‐TD. The absolute molecular weight averages, molecular weight distribution, radius of gyration, and solution conformation of the three HA lots were determined and compared by the two techniques. In addition, the intrinsic viscosity and intrinsic viscosity distribution were measured by SEC‐TD. © 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2012.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Proteoglycans and glycosaminoglycans research · Ocular Surface and Contact Lens · Glaucoma and retinal disorders
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. 10.1007/s10529-006-9219-z10.1007/s10529-006-9219-z ↗
2. 10.1016/j.clae.2009.02.00610.1016/j.clae.2009.02.006 ↗
3. 10.1016/j.biomaterials.2007.10.03910.1016/j.biomaterials.2007.10.039 ↗
4. Abbott Medical Optics. Available at:http://www.amo‐inc.com/products/cataract/ovds 2010.
5. 10.1007/s11095-008-9818-610.1007/s11095-008-9818-6 ↗
6. 10.1016/j.optm.2010.08.00310.1016/j.optm.2010.08.003 ↗
7. Comparative studies of various hyaluronic acids produced by microbial fermentation for potential topical ophthalmic applications10.1002/jbm.a.32481 ↗
8. 10.1002/bmc.18510.1002/bmc.185 ↗
9. 10.1016/j.ejcb.2006.05.00910.1016/j.ejcb.2006.05.009 ↗
10. 10.1016/j.polymdegradstab.2006.07.00910.1016/j.polymdegradstab.2006.07.009 ↗
11. 10.1385/IR:31:3:20710.1385/IR:31:3:207 ↗
12. 10.1002/jbm.a.3276010.1002/jbm.a.32760 ↗
13. 10.1016/S1063-4584(05)80319-X10.1016/S1063-4584(05)80319-X ↗
14. 10.1016/B978-008044382-9/50051-010.1016/B978-008044382-9/50051-0 ↗
15. 10.1002/jssc.20100041410.1002/jssc.201000414 ↗
16. 10.1002/jssc.20100047810.1002/jssc.201000478 ↗
17. 10.1016/j.carres.2007.02.01810.1016/j.carres.2007.02.018 ↗
18. 10.1016/j.chroma.2005.11.09410.1016/j.chroma.2005.11.094 ↗
19. Characterization of hyaluronic acid with on‐line differential viscometry, multiangle light scattering, and differential refractometry
20. 10.1007/s00249-003-0299-610.1007/s00249-003-0299-6 ↗
21. 2004
22. Robbins C. R. · 1979
23. Cirrus Multi Detector Software User Guide Revision 3.0.2007;13‐7 8 10.
24. 10.1063/1.174673810.1063/1.1746738 ↗
25. 10.1002/pi.263610.1002/pi.2636 ↗
26. 10.1016/j.carres.2005.01.02210.1016/j.carres.2005.01.022 ↗
27. 10.1016/B978-008044382-9/50032-710.1016/B978-008044382-9/50032-7 ↗
28. 10.1016/j.eurpolymj.2004.03.01010.1016/j.eurpolymj.2004.03.010 ↗
29. 10.1016/0003-2670(93)80373-S10.1016/0003-2670(93)80373-S ↗
30. 10.1002/(SICI)1097-4628(19960801)61:5<865::AID-APP20>3.0.CO;2-V10.1002/(SICI)1097-4628(19960801)61:5<865::AID-APP20>3.0.CO;2-V ↗
31. 10.1016/S0032-3861(02)00586-410.1016/S0032-3861(02)00586-4 ↗
32. 10.1021/bm034217810.1021/bm0342178 ↗
33. 10.1016/B978-008044382-9/50034-010.1016/B978-008044382-9/50034-0 ↗
34. 10.1002/app.3183410.1002/app.31834 ↗
35. 10.1016/S0144-8617(02)00298-910.1016/S0144-8617(02)00298-9 ↗
36. Determination of polymer structure by gel permeation chromatography
37. 10.17221/1930-VETMED10.17221/1930-VETMED ↗