journal article·2009-07

Tensile and tribological properties of high‐crystallinity radiation crosslinked UHMWPE

Alessandro Bistolfi, Mary Beth Turell, Ying‐Lung Lee, Anuj Bellare

Publisher page

Abstract

Abstract Osteolysis due to particulate wear debris associated with ultrahigh molecular weight polyethylene (UHMWPE) components of total joint replacement prostheses has been a major factor determining their in vivo lifetime. In recent years, radiation crosslinking has been employed to decrease wear rates in PE components, especially in acetabular cups of total hip replacement prostheses. A drawback of radiation crosslinking is that it leads to a crosslinked PE (or XPE) with lower mechanical properties compared with uncrosslinked PE. In contrast, high‐crystallinity PEs are known to have several mechanical properties higher than conventional PE. In this study, we hypothesized that increasing the crystallinity of radiation crosslinked and remelted XPE would result in an increase in tensile properties without compromising wear resistance. High‐pressure crystallization was performed on PE and XPE and analyzed for the resulting morphological alterations using differential scanning calorimeter, low voltage scanning electron microscopy, and ultrasmall angle X‐ray scattering. Uniaxial tensile tests showed that high‐pressure crystallization increased the tensile modulus and yield stress in both PE and XPE, decreased the ultimate strain and ultimate stress in PE but had no significant effect on ultimate strain or ultimate stress in XPE. Multidirectional wear tests demonstrated that high‐pressure crystallization decreased the wear resistance of PE but had no effect on the wear resistance of XPE. In conclusion, this study shows that high‐pressure crystallization can be effectively used to increase the crystallinity and modulus of XPE without compromising its superior wear resistance compared with PE. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. 10.1097/00003086-200112000-0000710.1097/00003086-200112000-00007 ↗
2. 10.1016/S0142-9612(99)00053-810.1016/S0142-9612(99)00053-8 ↗
3. The origin of submicron polyethylene wear debris in total hip arthroplasty
4. The Otto Aufranc Award. Impact of γ sterilization on clinical performance of polyethylene in the hip
5. 10.1016/S0142-9612(01)00288-510.1016/S0142-9612(01)00288-5 ↗
6. 10.1016/S0032-3861(98)00438-810.1016/S0032-3861(98)00438-8 ↗
7. 10.1016/0142-9612(95)00349-510.1016/0142-9612(95)00349-5 ↗
8. 10.1002/(SICI)1097-4636(1999)48:4<474::AID-JBM11>3.0.CO;2-T10.1002/(SICI)1097-4636(1999)48:4<474::AID-JBM11>3.0.CO;2-T ↗
9. 10.1302/0301-620X.80B2.823410.1302/0301-620X.80B2.8234 ↗
10. 10.2106/00004623-200012000-0000410.2106/00004623-200012000-00004 ↗
11. A study of the combined effects of shelf ageing following irradiation in air and counterface roughness on the wear of UHMWPE
12. The effect of conformity on stresses in dome‐shaped polyethylene patellar components
13. 10.2106/00004623-198668070-0001010.2106/00004623-198668070-00010 ↗
14. 10.1016/S0883-5403(05)80186-X10.1016/S0883-5403(05)80186-X ↗
15. Evaluation of contact stress in metal‐backed patellar replacements. A predictor of survivorship10.1097/00003086-199112000-00029 ↗
16. 10.1016/S0883-5403(96)80026-X10.1016/S0883-5403(96)80026-X ↗
17. The radiation improvement of polyethylene prostheses: A preliminary study10.1302/0301-620X.60B3.681412 ↗
18. 10.1007/BF0012141210.1007/BF00121412 ↗
19. 10.1016/S0142-9612(99)00039-310.1016/S0142-9612(99)00039-3 ↗
20. 10.1002/jor.110017020310.1002/jor.1100170203 ↗
21. 10.1016/S0736-0266(02)00073-610.1016/S0736-0266(02)00073-6 ↗
22. 10.1002/jbm.a.1060610.1002/jbm.a.10606 ↗
23. 10.1016/j.biomaterials.2005.09.01010.1016/j.biomaterials.2005.09.010 ↗
24. 10.1016/j.biomaterials.2005.09.03310.1016/j.biomaterials.2005.09.033 ↗
25. 10.1016/j.biomaterials.2005.06.02510.1016/j.biomaterials.2005.06.025 ↗
26. 10.1002/jbm.b.3080710.1002/jbm.b.30807 ↗
27. 10.1016/j.biomaterials.2005.05.10210.1016/j.biomaterials.2005.05.102 ↗
28. 10.1016/j.biomaterials.2005.04.02610.1016/j.biomaterials.2005.04.026 ↗
29. 10.1016/j.biomaterials.2003.12.04810.1016/j.biomaterials.2003.12.048 ↗
30. 10.1002/pol.1964.10002082810.1002/pol.1964.100020828 ↗
31. 10.1002/pol.1969.16007120710.1002/pol.1969.160071207 ↗
32. 10.1021/ma980261h10.1021/ma980261h ↗
33. An analysis of Hylamer and polyethylene bearings from retrieved acetabular components10.3928/0147-7447-19980801-09 ↗
34. 10.1002/pol.1979.18017040610.1002/pol.1979.180170406 ↗
35. 10.1021/ma00024a00310.1021/ma00024a003 ↗
36. 10.1021/ma050815y10.1021/ma050815y ↗
37. 10.1021/ma00045a03410.1021/ma00045a034 ↗
38. 10.1016/S0032-3861(98)00163-310.1016/S0032-3861(98)00163-3 ↗
39. Data evaluation in small‐angle scattering: calculation of the radial electron density by means of Indirect Fourier Transformation