journal article·2015-11-23Open access

Kelvin probe force microscopy for local characterisation of active nanoelectronic devices

Tino Wagner, Hannes Beyer, Patrick Reissner, Philipp Mensch, Heike Riel, Bernd Gotsmann, Andreas Stemmer

Abstract

Frequency modulated Kelvin probe force microscopy (FM-KFM) is the method of choice for high resolution measurements of local surface potentials, yet on coarse topographic structures most researchers revert to amplitude modulated lift-mode techniques for better stability. This approach inevitably translates into lower lateral resolution and pronounced capacitive averaging of the locally measured contact potential difference. Furthermore, local changes in the strength of the electrostatic interaction between tip and surface easily lead to topography crosstalk seen in the surface potential. To take full advantage of the superior resolution of FM-KFM while maintaining robust topography feedback and minimal crosstalk, we introduce a novel FM-KFM controller based on a Kalman filter and direct demodulation of sidebands. We discuss the origin of sidebands in FM-KFM irrespective of the cantilever quality factor and how direct sideband demodulation enables robust amplitude modulated topography feedback. Finally, we demonstrate our single-scan FM-KFM technique on an active nanoelectronic device consisting of a 70 nm diameter InAs nanowire contacted by a pair of 120 nm thick electrodes.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Force Microscopy Techniques and Applications · Mechanical and Optical Resonators · Molecular Junctions and Nanostructures

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (46)

Show source-provided references
1. 10.1116/1.58542310.1116/1.585423 ↗
2. 10.1063/1.10522710.1063/1.105227 ↗
3. 10.1063/1.114966410.1063/1.1149664 ↗
4. 10.1002/pssa.20130030210.1002/pssa.201300302 ↗
5. 10.1063/1.366518210.1063/1.3665182 ↗
6. 10.1103/PhysRevB.89.24545010.1103/PhysRevB.89.245450 ↗
7. 10.1103/PhysRevB.83.23543410.1103/PhysRevB.83.235434 ↗
8. 10.1063/1.481307610.1063/1.4813076 ↗
9. 10.1063/1.36818110.1063/1.368181 ↗
10. 10.1088/0957-4484/22/7/07550110.1088/0957-4484/22/7/075501 ↗
11. 10.1063/1.198808910.1063/1.1988089 ↗
12. 10.1088/0957-4484/24/29/29570210.1088/0957-4484/24/29/295702 ↗
13. 10.1103/PhysRevLett.91.26610110.1103/PhysRevLett.91.266101 ↗
14. 10.1088/0957-4484/18/22/22550510.1088/0957-4484/18/22/225505 ↗
15. 10.1063/1.34734710.1063/1.347347 ↗
16. 10.1063/1.12157710.1063/1.121577 ↗
17. 10.1016/S0169-4332(98)00538-810.1016/S0169-4332(98)00538-8 ↗
18. 10.1007/s10051005021910.1007/s100510050219 ↗
19. 10.3762/bjnano.5.110.3762/bjnano.5.1 ↗
20. 10.1103/PhysRevB.71.12542410.1103/PhysRevB.71.125424 ↗
21. 10.1063/1.133554610.1063/1.1335546 ↗
22. 10.1103/PhysRevB.56.1601010.1103/PhysRevB.56.16010 ↗
23. Carlson · 2009
24. 10.3762/bjnano.4.410.3762/bjnano.4.4 ↗
25. 10.1063/1.9922410.1063/1.99224 ↗
26. 10.1116/1.58553610.1116/1.585536 ↗
27. 10.1088/0957-4484/26/19/19570110.1088/0957-4484/26/19/195701 ↗
28. 10.1088/0957-4484/15/2/00410.1088/0957-4484/15/2/004 ↗
29. 10.1063/1.294774010.1063/1.2947740 ↗
30. 10.1116/1.58247210.1116/1.582472 ↗
31. 10.1063/1.487071010.1063/1.4870710 ↗
32. 2012
33. 10.1063/1.487333110.1063/1.4873331 ↗
34. 10.1088/0957-4484/17/15/01910.1088/0957-4484/17/15/019 ↗
35. Ziegler · Transactions of the ASME · 1942 · 64 · 759
36. 10.1103/RevModPhys.77.78310.1103/RevModPhys.77.783 ↗
37. Friedland · 2005
38. 10.1063/1.218322110.1063/1.2183221 ↗
39. 10.1063/1.138725310.1063/1.1387253 ↗
40. 10.1115/1.366255210.1115/1.3662552 ↗
41. 10.1115/1.365890210.1115/1.3658902 ↗
42. Simon · 200610.1002/0470045345 ↗
43. 10.1063/1.12607110.1063/1.126071 ↗
44. 10.1016/j.ijnonlinmec.2007.01.01810.1016/j.ijnonlinmec.2007.01.018 ↗
45. 10.3762/bjnano.2.210.3762/bjnano.2.2 ↗
46. 10.1063/1.472369710.1063/1.4723697 ↗