Functional properties and performance of new and reprocessed coronary angioplasty balloon catheters
Source abstract
Abstract
Abstract The need of health costs control has prompted the reuse of devices originally manufactured for single use only. To assess reprocessing feasibility of disposable medical devices, hygienic, technical, and functional aspects must be taken into account in addition to economical, ethical, and legal implications. This study aims to characterize coronary angioplasty catheters and to evaluate performance changes induced by reprocessing. Multiple analysis including crossing profile, slipperiness, compliance, mechanical, and burst pressure tests were performed at different steps of the protocol on 25 catheters reprocessed up to two times. The results highlighted that both use and reprocessing can affect the features of angioplasty catheters. Mechanical stress caused by clinical inflation and thermal–chemical stress undergone by polymers during cleaning and sterilization procedures caused partial modifications of material properties, inducing an overall shrinking effect on balloons. Compliance tests reported a maximum variation of 6.2% from nominal values, showing the conformity of reprocessed devices with manufacturers' original specifications (±10%). The burst pressure of reprocessed devices was 80% higher than the rated burst pressure certified by manufacturers, thus reducing concerns of breakage during reuse. A strict dependence on device model in the behavior of catheters was found, especially for balloons crossing profile and slipperiness. Main changes occurred after the first reprocessing cycle, while a second cleaning and sterilization did not introduce further significant alterations. On the whole, the magnitude of modifications introduced up to two reprocessing cycles did not compromise catheters performance. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Medical Device Sterilization and Disinfection · Cardiac, Anesthesia and Surgical Outcomes · Aortic aneurysm repair treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (29)
Show source-provided references
1. Food and Drug Administration Center for Devices and Radiological Health. US Department of Health and Human Services. FDA proposed strategy on reuse of single‐use devices (updated 1 November1999). Available athttp://www.fda.gov/cdrh/comp/guidance/1168.pdf.
2. Food and Drug Administration Center for Devices and Radiological Health US Department of Health and Human Services. Medical device user fee and modernization act of 2002 validation data in premarket notification submissions (510(k)s) for reprocessed single‐use medical devices; guidance for industry and FDA staff (issued 1 June2004). Available athttp://www.fda.gov/cdrh/ode/guidance/1216.pdf.
3. The reuse of single‐use cardiac catheters: safety, economical ethical and legal issues
4. Requirements for reprocessing single‐use medical devices
5. Hygienic requirements for processing of medical devices
6. Reuse of single‐use catheters: a dilemma to be clarified
7. 10.1016/S0735-1097(97)81410-610.1016/S0735-1097(97)81410-6 ↗
8. 10.1016/0735-1097(94)90142-210.1016/0735-1097(94)90142-2 ↗
9. 10.1016/S0002-9149(96)00443-210.1016/S0002-9149(96)00443-2 ↗
10. 10.1002/(SICI)1522-726X(199909)48:1<54::AID-CCD10>3.0.CO;2-H10.1002/(SICI)1522-726X(199909)48:1<54::AID-CCD10>3.0.CO;2-H ↗
11. 10.1016/S0002-9149(96)00392-X10.1016/S0002-9149(96)00392-X ↗
12. Randomized controlled trial of reuse of PTCA balloon catheters
13. A randomized study of the safety and efficacy of reused angioplasty balloon catheters
14. 10.1016/S0735-1097(97)00362-810.1016/S0735-1097(97)00362-8 ↗
15. 10.1016/S0002-8703(96)90554-210.1016/S0002-8703(96)90554-2 ↗
16. 10.1002/(SICI)1097-0304(199606)38:2<123::AID-CCD1>3.0.CO;2-B10.1002/(SICI)1097-0304(199606)38:2<123::AID-CCD1>3.0.CO;2-B ↗
17. 10.1053/euhj.1999.169110.1053/euhj.1999.1691 ↗
18. 10.3109/1073119000911935410.3109/10731190009119354 ↗
19. The effects of use and simulated reuse on percutaneous transluminal coronary angioplasty balloons and catheters
20. 10.1002/ccd.1039110.1002/ccd.10391 ↗
21. 10.1002/(SICI)1097-4636(199621)33:1<29::AID-JBM5>3.0.CO;2-O10.1002/(SICI)1097-4636(199621)33:1<29::AID-JBM5>3.0.CO;2-O ↗
22. 10.1002/1097-4636(200009)53:5<568::AID-JBM17>3.0.CO;2-810.1002/1097-4636(200009)53:5<568::AID-JBM17>3.0.CO;2-8 ↗
23. 10.1515/bmte.2000.45.6.14610.1515/bmte.2000.45.6.146 ↗
24. Kraft M · 2000
25. 10.1002/jbm.104710.1002/jbm.1047 ↗
26. The effects of high energy and EtO sterilization on thermoplastics
27. Possibilities and limitations of preparation for reusing angiography catheters
28. Reuse of angiography catheters. II. Effect of multiple sterilization on the properties of the catheter material—Physiochemical studies
29. 10.3109/0309190900901543310.3109/03091909009015433 ↗