journal article·2009-04

Frequency dependence of viscoelastic properties of medical grade silicones

A. Mahomed, N. M. Chidi, D. W. L. Hukins, S. N. Kukureka, D. E. T. Shepherd

Publisher page

Abstract

Abstract Cylinders of medical grade silicone elastomers, (29 mm in diameter and 13 mm thick), immersed in physiological saline solution at 37°C, were investigated by dynamic mechanical analysis (DMA). A sinusoidal cyclic compression of 40 ± 5 N was applied over a frequency range, f, of 0.02–100 Hz. Values of the storage, E′, and loss, E″, moduli for the cylinders were found to depend on f; the dependence of E′ or E″ on the logarithm (base 10) of f was represented by a third‐order polynomial. Above about 0.3 Hz, the cylindrical specimens appeared to be undergoing the onset of a transition from the rubbery to the glassy state. There was no significant difference between results obtained at 37 and 23°C; pretreatment of specimens in physiological saline at 37°C for 24 h and 29 days had no appreciable effect on the results. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Elasticity and Material Modeling · Bone fractures and treatments · Effects of Vibration on Health

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (49)

Show source-provided references
1. 10.1177/081012310.1177/0810123 ↗
2. Dynamic mechanical properties of silicone maxillofacial prosthetic materials and the influence of frequency and temperature on their properties
3. Measurement of dynamic properties of silicone rubbers
4. 10.4028/www.scientific.net/MSF.473-474.8510.4028/www.scientific.net/MSF.473-474.85 ↗
5. 10.1016/S0022-3913(05)80077-010.1016/S0022-3913(05)80077-0 ↗
6. 10.1016/j.jbiomech.2005.03.01910.1016/j.jbiomech.2005.03.019 ↗
7. 10.1088/0022-3727/36/15/32410.1088/0022-3727/36/15/324 ↗
8. 10.1016/S0142-9612(98)00236-110.1016/S0142-9612(98)00236-1 ↗
9. 10.1016/S0142-9612(00)00010-710.1016/S0142-9612(00)00010-7 ↗
10. 10.1140/epje/i2007-10182-710.1140/epje/i2007-10182-7 ↗
11. 10.1016/j.polymer.2005.02.06010.1016/j.polymer.2005.02.060 ↗
12. 10.1016/S1359-0286(02)00030-X10.1016/S1359-0286(02)00030-X ↗
13. Doi M · 1986
14. 10.1088/0031-8949/1991/T35/00210.1088/0031-8949/1991/T35/002 ↗
15. 10.1586/17434440.1.2.19310.1586/17434440.1.2.193 ↗
16. 10.1016/S1350-4533(96)00075-610.1016/S1350-4533(96)00075-6 ↗
17. Gordon DA · 1998 · 3.4.1
18. 10.1243/095441105X921910.1243/095441105X9219 ↗
19. 10.1016/S1350-4533(02)00148-010.1016/S1350-4533(02)00148-0 ↗
20. 10.1016/S0266-7681(05)80038-510.1016/S0266-7681(05)80038-5 ↗
21. 10.1016/j.jhsa.2004.04.02310.1016/j.jhsa.2004.04.023 ↗
22. 10.1016/j.jhsa.2004.03.00810.1016/j.jhsa.2004.03.008 ↗
23. 10.1243/095441102153624310.1243/0954411021536243 ↗
24. Ward IM · 1990 · 95
25. Ferry JD · 1961 · 11
26. 10.1002/jbm.b.3104210.1002/jbm.b.31042 ↗
27. 10.1002/jbm.b.3089910.1002/jbm.b.30899 ↗
28. 10.1002/jbm.82028101110.1002/jbm.820281011 ↗
29. 10.1002/(SICI)1097-4636(199710)37:1<94::AID-JBM11>3.0.CO;2-Q10.1002/(SICI)1097-4636(199710)37:1<94::AID-JBM11>3.0.CO;2-Q ↗
30. 10.1097/00003086-199709000-0000410.1097/00003086-199709000-00004 ↗
31. 10.1097/00003086-199709000-0000210.1097/00003086-199709000-00002 ↗
32. 10.1016/S0363-5023(05)80104-210.1016/S0363-5023(05)80104-2 ↗
33. BSI British Standards.Physical Testing of Rubber‐Part A6: Method for Determination of Compression Set at Ambient Elevated or Low Temperatures. Volume BS 903‐A6:1992; ISO 815:1991. London: BSI British Standards;1992:18.
34. 10.1016/0072-968X(71)90012-X10.1016/0072-968X(71)90012-X ↗
35. 10.1243/PIME_PROC_1990_204_261_0210.1243/PIME_PROC_1990_204_261_02 ↗
36. Advances in hand surgery: Finger joint implants
37. 10.1016/0363-5023(94)90259-310.1016/0363-5023(94)90259-3 ↗
38. 10.1142/S021951940700224810.1142/S0219519407002248 ↗
39. Total joint arthroplasty. The hand
40. 10.1243/PIME_PROC_1996_210_386_0210.1243/PIME_PROC_1996_210_386_02 ↗
41. 10.1016/j.medengphy.2006.02.00410.1016/j.medengphy.2006.02.004 ↗
42. Kreyszig E · 2006 · 1049
43. James G · 1993 · 778
44. 10.1023/A:102508840567410.1023/A:1025088405674 ↗
45. Benham PP · 1996 · 514
46. Durability of silicone implants—An in vivo study10.1016/S0030-5898(20)30840-3 ↗
47. 10.1002/jbm.82015040710.1002/jbm.820150407 ↗
48. Ferry JD · 1961 · 201
49. Nielsen LE · 1974 · 19