New polyoxazoline loaded patches for hemostasis in experimental liver resection
Source abstract
Abstract
Abstract A new cost‐effective NHS functionalized polyoxazoline (POx) loaded polymer with strong hemostatic properties has been developed. In this study, we investigate POx loaded hemostatic patches regarding hemostatic efficacy, local inflammatory reaction and wound‐healing, as compared to the non‐POx treated blanks and commercially available hemostatic products. Hundred and ten rats divided into 11 groups of 10 animals underwent partial liver lobe resection. Eight groups received experimental patches, two groups commercially available hemostatic patches (TachoSil® and Veriset™, positive controls), one group with gauzes (negative control). Each animal received twice a patch with a size 1.5 × 2.5 cm, on each partially resected lobe. Primary endpoint was time to hemostasis (TTH). The rats were sacrificed at different time points (1, 3, or 7 days) to measure local inflammatory response and early wound healing. Of the POx loaded patches, GFC NHS‐POx (TTH 20.4 s, p = .019) and GFC‐NHS‐POx1.5 (TTH 0.0 s, p = .003) showed significantly faster TTH compared to TachoSil® (TTH 95.4 s), and were comparable to Veriset™ (TTH 17.0 s). Three patches, GFC‐NHS‐POx 1.5 (TTH 0.0 s, p = .016), ORC NHS‐POx:NU‐POx (TTH 91.4 s, p = .033), and ORC‐PLGA NHS‐POx:NU‐POx (TTH 105.6 s, p = .04) had a lower TTH compared to their own blank carrier (TTH 74.9, 157.8, and 195.7 s, respectively). With regard to biocompatibility, all POx loaded patches showed results comparable to TachoSil® and Veriset™. NHS‐POx‐loaded hemostatic patch demonstrate fast and effective hemostasis, comparable or better than commercially available hemostatic patches, with similar early biocompatibility.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Hemostasis and retained surgical items · Surgical Sutures and Adhesives · 3D Printing in Biomedical Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Surgery, RadboudUMC Nijmegen The Netherlands
GATT Technologies BV Nijmegen The Netherlands
References (27)
Show source-provided references
1. 10.1007/s00464-009-0597-x10.1007/s00464-009-0597-x ↗
2. 10.1097/SLA.0b013e3181b674df10.1097/SLA.0b013e3181b674df ↗
3. 10.1111/j.1477-2574.2009.00065.x10.1111/j.1477-2574.2009.00065.x ↗
4. 10.1111/hpb.1200910.1111/hpb.12009 ↗
5. 10.1007/s00423-014-1215-510.1007/s00423-014-1215-5 ↗
6. 10.1016/j.transci.2011.10.01310.1016/j.transci.2011.10.013 ↗
7. 10.1002/jhbp.38910.1002/jhbp.389 ↗
8. 10.1002/jbm.b.3166310.1002/jbm.b.31663 ↗
9. 10.1016/j.cap.2010.08.03110.1016/j.cap.2010.08.031 ↗
10. 10.1007/s10353-013-0222-z10.1007/s10353-013-0222-z ↗
11. 10.1016/j.carbpol.2012.01.05810.1016/j.carbpol.2012.01.058 ↗
12. 10.1177/088532821454550010.1177/0885328214545500 ↗
13. 10.1021/acs.biomac.7b0068310.1021/acs.biomac.7b00683 ↗
14. 10.1371/journal.pbio.100041210.1371/journal.pbio.1000412 ↗
15. 10.1016/j.colsurfb.2008.04.00510.1016/j.colsurfb.2008.04.005 ↗
16. Pathophysiology and classification of adhesions
17. 10.1016/0002-9610(92)90255-P10.1016/0002-9610(92)90255-P ↗
18. Histological evaluation of wound healing process after photodynamic therapy of rat Oral mucosal ulcer
19. A randomized, controlled trial of Veriset hemostatic patch in halting cardiovascular bleeding
20. 10.1016/j.nano.2015.01.00110.1016/j.nano.2015.01.001 ↗
21. 10.1016/j.rvsc.2012.04.01210.1016/j.rvsc.2012.04.012 ↗
22. 10.1016/j.cellimm.2017.12.00510.1016/j.cellimm.2017.12.005 ↗
23. 10.1016/j.bpj.2017.02.02110.1016/j.bpj.2017.02.021 ↗
24. 10.1002/bjs.913110.1002/bjs.9131 ↗
25. 10.1186/s12967-019-2052-710.1186/s12967-019-2052-7 ↗
26. 10.1016/0300-9629(85)90728-510.1016/0300-9629(85)90728-5 ↗
27. An in vivo comparison of the efficacy of hemostatic powders, using two porcine bleeding models