journal article·2005-10

Design of functionally graded dental implant in the presence of cancellous bone

H. S. Hedia

Publisher page

Abstract

Abstract In a previous work by the author [Hedia HS, Mahmoud NA. Biomed Mater Eng 2004;14(2):133–143], a functionally graded material (FGM) dental implant was designed without cancellous bone in the model. In this investigation, the effect of the presence of cancellous bone as a thin layer around the dental implant was investigated. It is well known that the main inorganic component of natural bone is hydroxyapatite (HAP) and that the main organic component is collagen (Col). HAP implants are not bioabsorbable, and because induction of bone into and around the artificially made HAP is not always satisfactory, loosening or breakage of HAP implants might occur after implantation in the clinical application. The development of a new material that is bioabsorbable and that has osteoconductive activity is needed. Therefore, the aim of the current investigation was to design an implant, in the presence of cancellous bone as a thin layer around it, from FGM. In this study, a novel biomaterial, Col/HAP, as a FGM, was developed using the finite element and optimization techniques that are available in the ANSYS package. These materials have a self‐organized character similar to that of natural bone. The investigations have shown that the maximum stress in the cortical bone and cancellous bone for the Col/HAP functionally graded implant has been reduced by about 40% and 19%, respectively, compared with currently used titanium dental implants. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2005
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Endodontics and Root Canal Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (32)

Show source-provided references
1. 10.1016/S1359-6454(98)80035-910.1016/S1359-6454(98)80035-9 ↗
2. KattiK GujjulaP.Control of mechanical responses inin situpolymer‐hydroxyapatite composites for bone replacement: The 15th Engineering Mechanics Conference of the ASCE; June 2–5 2002; Columbia University New York.
3. 10.1557/JMR.1998.001510.1557/JMR.1998.0015 ↗
4. 10.1007/s10019000010310.1007/s100190000103 ↗
5. 10.1016/S1350-4533(98)00073-310.1016/S1350-4533(98)00073-3 ↗
6. ItohS KawauchiT ShinomiyaK KoyamaY MatumotoH TakakudaK MasanoriK TanakaJ.Osteoconductive activity of a novel biomaterial hydroxyapatite/collagen composite: 46th annual meeting Orthopaedic Research Society; March 12–15 2000; Orlando FL.
7. Suresh S · 1998
8. Properties of titanium/hydroxyapatite functionally graded implants by spark plasma sintering and their biocompatibility
9. BoughtonP RuysAJ. Ceramic‐polymer functionally graded material: a novel spinal disk prosthesis. Available from:http://www.materials.unsw.edu.au. Accessed August2000.
10. 10.1115/1.289720110.1115/1.2897201 ↗
11. 10.1115/1.278891410.1115/1.2788914 ↗
12. 10.1115/1.278889310.1115/1.2788893 ↗
13. 10.1115/1.290152910.1115/1.2901529 ↗
14. Crack‐tip singularity fields in non‐homogeneous body under thermal stress fields
15. 10.1080/0149573930894622410.1080/01495739308946224 ↗
16. 10.1115/1.309734110.1115/1.3097341 ↗
17. Fuchiyama T · 1993 · 425
18. FujimotoT NodaN.Multiple crack growths in the functionally graded plate under thermal shock. Proceedings of the 4th International Congress on Thermal Stresses; June 8–11 2001; Osaka Japan. p121–124.
19. 10.1016/j.ijsolstr.2003.08.01710.1016/j.ijsolstr.2003.08.017 ↗
20. Design optimization of functionally graded dental implant
21. 10.1088/0370-1301/69/8/30510.1088/0370-1301/69/8/305 ↗
22. Kingery WD · 1976
23. 10.1243/PIME_PROC_1993_207_285_0210.1243/PIME_PROC_1993_207_285_02 ↗
24. ANSYS user's manual Version 5.0A.1992.
25. Zienkiewicz OC · 1977
26. 10.1243/PIME_PROC_1992_206_295_0210.1243/PIME_PROC_1992_206_295_02 ↗
27. Stress and strain distribution behavior in the bone due to the effect of cancellous bone dental implant material and the bone height
28. 10.1007/978-1-4612-4866-8_1510.1007/978-1-4612-4866-8_15 ↗
29. 10.1243/EMED_JOUR_1988_017_043_0210.1243/EMED_JOUR_1988_017_043_02 ↗
30. 10.1007/BF0240614310.1007/BF02406143 ↗
31. 10.1007/978-1-4612-4866-8_1810.1007/978-1-4612-4866-8_18 ↗
32. 10.1007/978-1-4612-4866-8_1510.1007/978-1-4612-4866-8_15 ↗