Plasma‐deposited tetraglyme surfaces greatly reduce total blood protein adsorption, contact activation, platelet adhesion, platelet procoagulant activity, and in vitro thrombus deposition
Source abstract
Abstract
Abstract The ability of tetraethylene glycol dimethyl ether (tetraglyme) plasma deposited coatings exhibiting ultralow fibrinogen adsorption to reduce blood activation was studied with six in vitro methods, namely fibrinogen and von Willebrand's factor adsorption, total protein adsorption, clotting time in recalcified plasma, platelet adhesion and procoagulant activity, and whole blood thrombosis in a disturbed flow catheter model. Surface plasmon resonance results showed that tetraglyme surfaces strongly resisted the adsorption of all proteins from human plasma. The clotting time in the presence of tetraglyme surfaces was lengthened compared with controls, indicating a lower activation of the intrinsic coagulation cascade. Platelet adhesion and thrombin generation by adherent platelets were greatly reduced on tetraglyme‐coated materials, compared with uncoated and Biospan®‐coated glass slides. In the in vitro disturbed blood flow model, tetraglyme plasma coated catheters had 50% less thrombus than did the uncoated catheters. Tetraglyme‐coated materials thus had greatly reduced blood interactions as measured with all six methods. The improved blood compatibility of plasma‐deposited tetraglyme is thus not only due to their reduced platelet adhesion and activation, but also to a generalized reduction in blood interactions. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res 2007
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Polymer Surface Interaction Studies · Blood properties and coagulation · Dendrimers and Hyperbranched Polymers
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (44)
Show source-provided references
1. 10.1163/15685620074421910.1163/156856200744219 ↗
2. 10.1163/156856299X0065810.1163/156856299X00658 ↗
3. 10.1016/0079-6700(95)00011-410.1016/0079-6700(95)00011-4 ↗
4. Sefton MV · 2004 · 456
5. 10.1016/S0927-7765(99)00152-610.1016/S0927-7765(99)00152-6 ↗
6. 10.1163/15685620074422810.1163/156856200744228 ↗
7. 10.1163/15685620074365210.1163/156856200743652 ↗
8. 10.1163/156856299X0054010.1163/156856299X00540 ↗
9. 10.1016/1054-8807(93)90054-610.1016/1054-8807(93)90054-6 ↗
10. Hanson SR · 2004 · 332
11. 10.1002/(SICI)1097-4636(199902)44:2<130::AID-JBM2>3.0.CO;2-910.1002/(SICI)1097-4636(199902)44:2<130::AID-JBM2>3.0.CO;2-9 ↗
12. 10.1002/jbm.a.3036510.1002/jbm.a.30365 ↗
13. 10.1002/jbm.82026040210.1002/jbm.820260402 ↗
14. 10.1007/BF0253282310.1007/BF02532823 ↗
15. 10.1163/15685620175325250710.1163/156856201753252507 ↗
16. Glow discharge plasma treatment of polyethylene tubing with tetraglyme results in ultralow fibrinogen adsorption and greatly reduced platelet adhesion
17. 10.1055/s-0038-166105210.1055/s-0038-1661052 ↗
18. 10.1002/jbm.1004810.1002/jbm.10048 ↗
19. 10.1021/la052143a10.1021/la052143a ↗
20. 10.1021/la00011a03410.1021/la00011a034 ↗
21. 10.1021/ac950402310.1021/ac9504023 ↗
22. 10.1163/15685620232025391010.1163/156856202320253910 ↗
23. 10.1021/la971228b10.1021/la971228b ↗
24. 10.1002/jbm.a.3038110.1002/jbm.a.30381 ↗
25. 10.1002/1097-4636(20000915)51:4<669::AID-JBM15>3.0.CO;2-#10.1002/1097-4636(20000915)51:4<669::AID-JBM15>3.0.CO;2-# ↗
26. 10.1016/S0142-9612(00)00150-210.1016/S0142-9612(00)00150-2 ↗
27. 10.1002/(SICI)1097-4636(19980915)41:4<657::AID-JBM18>3.0.CO;2-B10.1002/(SICI)1097-4636(19980915)41:4<657::AID-JBM18>3.0.CO;2-B ↗
28. 10.1114/1.24310.1114/1.243 ↗
29. 10.1088/0305-4608/17/1/03110.1088/0305-4608/17/1/031 ↗
30. 10.1021/ac00020a02510.1021/ac00020a025 ↗
31. 10.1021/jp047332110.1021/jp0473321 ↗
32. Antonsen KP · 1992
33. 10.1016/S0142-9612(00)00031-410.1016/S0142-9612(00)00031-4 ↗
34. 10.1002/jbm.a.2008810.1002/jbm.a.20088 ↗
35. 10.1021/bm010072y10.1021/bm010072y ↗
36. 10.1002/jbm.a.2002410.1002/jbm.a.20024 ↗
37. 10.1002/jbm.82015050610.1002/jbm.820150506 ↗
38. 10.1002/jbm.a.3042410.1002/jbm.a.30424 ↗
39. In vivo evaluation of artificial surfaces with a nonhuman primate model of arterial thrombosis
40. 10.1007/BF0236412210.1007/BF02364122 ↗
41. 10.1021/la036274s10.1021/la036274s ↗
42. JohnstonEE.Surface and biological properties of biofouling‐resistant poly(ethylene oxide)‐like plasma deposited films. Ph.D. Dissertation University of Washington 1997.
43. 10.1021/la010384m10.1021/la010384m ↗
44. 10.1111/j.1749-6632.1987.tb33041.x10.1111/j.1749-6632.1987.tb33041.x ↗