journal article·2005-07

Effects of soluble metals on human peri‐implant cells

Nadim James Hallab, Shelley Anderson, Marco Caicedo, Amee Brasher, Katalin Mikecz, Joshua J. Jacobs

Publisher page

Abstract

Abstract Despite reports associating tissue necrosis with implant failure, the degree to which processes, such as metal toxicity, negatively impact implant performance is unknown. We evaluated representative human peri‐implant cells (i.e., osteoblasts, fibroblasts, and lymphocytes) when challenged by Al+3, Co+2, Cr+3, Fe+3, Mo+5, Ni+2, and V+3 chloride solutions (and Na+2 as a control) over a wide range of concentrations (0.01–10.0 mM). Cell responses were measured using proliferation assays, viability assays, and microscopic cell morphology assessments. Differential effects were found to be less a function of the cell type than of the composition and concentration of metal challenge. No preferential immunosuppression was demonstrated. Below 0.01 mM, no metal was toxic. The most toxic metals (i.e., Co, Ni, and V) reduced proliferation (IC50), and viability (LC50) and cell morphology of osteoblasts, fibroblasts, and lymphocytes by <50% at challenge concentrations <1 mM. All other metals tested required >5 mM to exact the same responses. Below 1 mM, these toxic metals also induced alterations in all cell morphology consisting of loss of filopodia or lamellipodia or changes in cell shape. Metals that were toxic at clinically relevant concentrations (less than previously reported values in peri‐implant tissues/fluids) include Co (0.6 mM), Ni (0.8 mM), V (0.5 mM) for lymphocytes and Co (0.8 mM), V (0.3 mM), Al (1–5 mM), Fe (1–5 mM) for fibroblasts, and Co (0.8 mM), Ni (0.7 mM), V (0.1 mM) for osteoblasts. Only Co and V were toxic in vitro at concentrations below that detected in vivo in synovial fluid (V at 0.1 mM and Co at 0.8 mM for fibroblasts, and V at 0.4 mM and Co at 0.8 mM on osteoblasts). Thus, soluble Co and V released from Co‐ and Ti‐based alloys, respectively, could be implicated as the most likely to mediate cell toxicity in the periprosthetic milieu. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Heavy Metal Exposure and Toxicity

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (50)

Show source-provided references
1. Jacobs J · 1999 · 402
2. 10.1097/00003086-199608001-0001710.1097/00003086-199608001-00017 ↗
3. CampbellPA McKellopH AlimR MirraJ NuttS AmstutzHC.Metal‐on‐metal hip replacements: Wear performance and cellular response to wear particles. In:DisegiR KennedyRL PilliarRM editors.Cobalt‐base alloys for biomedical applications ASTMSTP 1365.West Conshohocken PA:American Society for Testing and Materials;1999. p193–200.10.1520/STP14274S ↗
4. 10.2106/00004623-198870080-0001710.2106/00004623-198870080-00017 ↗
5. 10.1002/(SICI)1097-4636(20000305)49:3<353::AID-JBM8>3.0.CO;2-T10.1002/(SICI)1097-4636(20000305)49:3<353::AID-JBM8>3.0.CO;2-T ↗
6. 10.1097/00007632-199905010-0001110.1097/00007632-199905010-00011 ↗
7. 10.1097/00003086-199807000-0000510.1097/00003086-199807000-00005 ↗
8. Metallic debris in femoral endosteolysis in failed cemented total hip arthroplasties
9. 10.1302/0301-620X.76B1.830068410.1302/0301-620X.76B1.8300684 ↗
10. Jacobs JJ · 1992
11. 10.2106/00004623-199409000-0000910.2106/00004623-199409000-00009 ↗
12. Particles of metal alloys and their corrosion products in the liver, spleen and para‐aortic lymph nodes of patients with total hip replacement prosthesis
13. Histologic, biochemical and ion analysis of tissue and fluids retrieved during total hip arthroplasty
14. Systemic distribution of metal degradation products from titanium alloy total hip replacements: an autopsy study
15. 10.1007/BF0039387610.1007/BF00393876 ↗
16. 10.1002/jab.77005010310.1002/jab.770050103 ↗
17. 10.1097/00003086-199612000-0000610.1097/00003086-199612000-00006 ↗
18. Local and distant products from modularity
19. 10.2106/00004623-200004000-0000210.2106/00004623-200004000-00002 ↗
20. 10.1159/00023745610.1159/000237456 ↗
21. 10.1002/(SICI)1097-4636(199701)34:1<29::AID-JBM5>3.0.CO;2-P10.1002/(SICI)1097-4636(199701)34:1<29::AID-JBM5>3.0.CO;2-P ↗
22. 10.1016/0109-5641(94)90025-610.1016/0109-5641(94)90025-6 ↗
23. 10.1002/jbm.82028040410.1002/jbm.820280404 ↗
24. 10.1016/0109-5641(93)90116-810.1016/0109-5641(93)90116-8 ↗
25. 10.1002/(SICI)1097-4636(199705)35:2<265::AID-JBM14>3.0.CO;2-G10.1002/(SICI)1097-4636(199705)35:2<265::AID-JBM14>3.0.CO;2-G ↗
26. 10.1016/0142-9612(96)00009-910.1016/0142-9612(96)00009-9 ↗
27. 10.1002/jab.77006040610.1002/jab.770060406 ↗
28. 10.1002/jab.77006020510.1002/jab.770060205 ↗
29. 10.1002/(SICI)1097-4636(199902)44:2<176::AID-JBM8>3.0.CO;2-610.1002/(SICI)1097-4636(199902)44:2<176::AID-JBM8>3.0.CO;2-6 ↗
30. 10.1016/S0142-9612(97)00234-210.1016/S0142-9612(97)00234-2 ↗
31. 10.1016/S0142-9612(97)00149-X10.1016/S0142-9612(97)00149-X ↗
32. 10.1002/(SICI)1097-4636(19981205)42:3<443::AID-JBM14>3.0.CO;2-H10.1002/(SICI)1097-4636(19981205)42:3<443::AID-JBM14>3.0.CO;2-H ↗
33. 10.1046/j.1365-2842.1998.00197.x10.1046/j.1365-2842.1998.00197.x ↗
34. 10.1097/00003086-199706000-0003010.1097/00003086-199706000-00030 ↗
35. 10.1002/jbm.1010610.1002/jbm.10106 ↗
36. Metal specific responses dominate in vitro hypersensitivity reactions in patients with total joint arthroplasty
37. 10.1002/jbm.a.1042910.1002/jbm.a.10429 ↗
38. 10.2106/00004623-199802000-0001510.2106/00004623-199802000-00015 ↗
39. 10.1002/jor.110007030210.1002/jor.1100070302 ↗
40. 10.1016/0142-9612(83)90003-010.1016/0142-9612(83)90003-0 ↗
41. 10.1126/science.289.5484.150110.1126/science.289.5484.1501 ↗
42. 10.1002/1097-0177(2000)9999:9999<::AID-DVDY1074>3.0.CO;2-C10.1002/1097-0177(2000)9999:9999<::AID-DVDY1074>3.0.CO;2-C ↗
43. Jacobs JJ · 1994 · 279
44. 10.1097/00003086-199901000-0002110.1097/00003086-199901000-00021 ↗
45. 10.2106/00004623-199810000-0000610.2106/00004623-199810000-00006 ↗
46. 10.2106/00004623-199405000-0001110.2106/00004623-199405000-00011 ↗
47. 10.1097/00003086-200112000-0000810.1097/00003086-200112000-00008 ↗
48. HallabNJ MikeczK AkramiJ JacobsJ.Differential metal release and protein binding associated with titanium and cobalt‐chromium implant alloys. Trans 46th Orthop Res Soc2000 Orlando FL.
49. 10.1002/(SICI)1097-4636(20000305)49:3<353::AID-JBM8>3.0.CO;2-T10.1002/(SICI)1097-4636(20000305)49:3<353::AID-JBM8>3.0.CO;2-T ↗
50. 10.1016/0142-9612(86)90084-010.1016/0142-9612(86)90084-0 ↗