journal article·2013-04

Novel creatine biosensors based on all solid-state contact ammonium-selective membrane electrodes

Melda Altikatoglu, Emine Karakus, Vildan Erci, Sule Pekyardımcı, Ibrahim Isildak

Publisher page

Abstract

Novel creatine bienzymatic potentiometric biosensors were prepared by immobilizing urease and creatinase on all solid-state contact PVC-containing palmitic acid and carboxylated PVC matrix membrane ammonium-selective electrodes without inner reference solution. Potentiometric characteristics of biosensors were examined in physiological model solutions at different creatine concentrations. The linear working range and long-term sensitivity of the biosensors were also determined. The creatine biosensors prepared by using the carboxylated PVC membrane electrodes showed more effective performance than those of the PVC containing palmitic acid membrane electrodes. Creatine assay in serum samples was successfully carried out by using the standard addition method.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Analytical Chemistry and Sensors · Electrochemical sensors and biosensors · Electrochemical Analysis and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (44)

Show source-provided references
1. Adeloju SB · Anal Chim Acta · 1996 · 323 · 10710.1016/0003-2670(95)00562-5 ↗
2. Alegret S · Biosensors · 1989 · 4 · 28710.1016/0265-928X(89)80010-0 ↗
3. Bilitewski U · Sensors and Actuators B · 1992 · 7 · 35110.1016/0925-4005(92)80323-P ↗
4. Buck RP · Anal Chem · 1972 · 44 · 270R10.1021/ac60313a011 ↗
5. Burke DG · J Chromatogr B · 1999 · 732 · 47910.1016/S0378-4347(99)00318-7 ↗
6. Chou NH · IEEE Sensors Journal · 2009 · 9 · 66510.1109/JSEN.2009.2016610 ↗
7. Clark EA · J Pharm Biomed Anal. · 2001 · 25 · 79510.1016/S0731-7085(01)00340-5 ↗
8. Del Campo G. · Fresenius J Ana. Chem · 1995 · 352 · 55710.1007/BF00323073 ↗
9. Elmosallamy MAF · Analytica Chimica Acta · 2006 · 564 · 25310.1016/j.aca.2006.01.103 ↗
10. Evans A · 1991
11. Jaffe M · Z Physiol Chem · 1886 · 10 · 391
12. Karakus E · Artif Cells Blood Substit Immobil Biotechnol · 2005 · 33 · 32910.1081/BIO-200066632 ↗
13. Karakus E · Process Biochemistry · 2006 · 41 · 137110.1016/j.procbio.2006.01.017 ↗
14. Kim EJ · Anal Chim Acta · 1999 · 394 · 22510.1016/S0003-2670(99)00308-6 ↗
15. Koncki R · Anal Lett · 1994 · 27 · 47510.1080/00032719408001088 ↗
16. Koncki R · Anal Chim Acta · 2000 · 418 · 21310.1016/S0003-2670(00)00961-2 ↗
17. Koncki R · Anal Chim Acta · 1996 · 333 · 21510.1016/0003-2670(96)00266-8 ↗
18. Lad U · Anal Chem · 2008 · 80 · 791010.1021/ac801500t ↗
19. Lakshmi D · Biosensors and Bioelectronics · 2007 · 22 · 330210.1016/j.bios.2006.12.011 ↗
20. Lucio D · Biotechnol Appl Biochem · 1999 · 29 · 6710.1111/j.1470-8744.1999.tb01149.x ↗
21. Ma SC · Anal Chem · 1988 · 60 · 229310.1021/ac00171a027 ↗
22. Magalhães MCS · The Analyst · 2002 · 127 · 106910.1039/B201173E ↗
23. Motonaka J · Bull Chem Soc Jpn · 1988 · 61 · 334210.1246/bcsj.61.3341 ↗
24. Pan TM · IEEE Sensors Journal, · 2011 · 11 · 238810.1109/JSEN.2011.2122255 ↗
25. Patel AK · Thin Solid Films · 2010 · 518 · 284710.1016/j.tsf.2009.09.009 ↗
26. Pezzanti JL · Clin Biomed · 2001 · 34 · 239
27. Pookaiyaudom P · Sensors and Actuators B · 2011 · 153 · 45310.1016/j.snb.2010.11.015 ↗
28. Premanode B · Sensors and Actuators B · 2007 · 120 · 73210.1016/j.snb.2006.03.051 ↗
29. Radomska A · Analytica Chimica Acta · 2004 · 523 · 19310.1016/j.aca.2004.06.048 ↗
30. Richard PB · Pure and Appl Chem · 1994 · 66 · 252710.1351/pac199466122527 ↗
31. 10.1081/JLC-10010853810.1081/JLC-100108538 ↗
32. Schwedhelm E · J Chromatogr B: Biomed Appl · 2000 · 744 · 9910.1016/S0378-4347(00)00236-X ↗
33. Sena SF · Clin Chem · 1988 · 134 · 59410.1093/clinchem/34.3.594 ↗
34. Shin JH · Sensors and Actuators B · 1998 · 50 · 1910.1016/S0925-4005(98)00151-8 ↗
35. Soldatkin AP · Materials Science and Engineering C · 2002 · 21 · 7510.1016/S0928-4931(02)00062-0 ↗
36. Stefan RI · Simultaneous determination of creatine and creatinine using amperometric biosensors Aboul-Enein Talanta · 2003 · 60 · 1223
37. Stefan RI · Biochemistry & Biotechnology · 2006 · 36 · 287
38. Suzuki H · Biosensors & Bioelectronics · 2001 · 16 · 72510.1016/S0956-5663(01)00214-7 ↗
39. Tinkilic N · Anal Chim Acta · 2002 · 452 · 2410.1016/S0003-2670(01)01441-6 ↗
40. Umezawa Y · Pure Appl Chem · 2000 · 72 · 185110.1351/pac200072101851 ↗
41. Walcerz I · Anal Lett · 1996 · 29 · 193910.1080/00032719608000800 ↗
42. Wang Y · strain WB1 Process Biochemistry · 2006 · 41 · 207210.1016/j.procbio.2006.05.009 ↗
43. Wegmann R · Microchim cta · 1984 · 111 · 110.1007/BF01204153 ↗
44. Yang YD · Biomed. Chromatogr · 1998 · 12 · 4710.1002/(SICI)1099-0801(199803/04)12:2<47::AID-BMC717>3.0.CO;2-Y ↗