Improved flowing behaviour and gas exchange of stored red blood cells by a compound porous structure
Source abstract
Abstract
Storage lesions in red blood cells (RBCs) hinder efficient circulation and tissue oxygenation. The absence of flow mechanics and gas exchange may contribute to this problem. To test if in vitro compensation of flow mechanics and gas exchange helps RBC recovery, three-dimensional polydimethylsiloxane (PDMS) porous structures were fabricated with a sugar mould, simulating lung alveoli. RBC suspensions were passed through the porous structure cyclically, simulating in vivo blood circulation. Acid-base indices, partial gas pressures, ions, glucose and RBC indices were analyzed. An atomic force microscope was used to investigate local mechanical properties of intact RBCs. RBCs suspensions that passed through the porous structures had a higher pH and oxygen partial pressure, and a lower potassium concentration and carbon dioxide partial pressure. Meantime they had better biochemical properties relative to static samples, namely, they exhibited a more homogenous distribution of Young's Modulus. RBCs that passed through a PDMS porous structure were healthier than static ones, giving hints to prevent RBC storage lesions.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Erythrocyte Function and Pathophysiology · Blood properties and coagulation · Microfluidic and Capillary Electrophoresis Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Life Sciences, University of Chinese Academy of Sciences
Chinese Medical College, Tianjin University of Traditional Chinese Medicine
National Centre for Nanoscience and Technology
Institute of Health Service and Transfusion Medicine, Beijing Key Laboratory of Blood Safety and Supply Technologies, Academy of Military Medical Sciences
References (54)
Show source-provided references
1. García-Roa M, Del CV-AM, Bobes AM, et al. Red blood cell storage time and transfusion: current practice, concerns and future perspectives. Blood Transfus. 2017;15:222–231
2. 10.1080/17474086.2016.124305110.1080/17474086.2016.1243051 ↗
3. Sharma S, Sharma P, Tyler LN. Transfusion of blood and blood products: indications and complications. Am Fam Physician. 2011;83:719–724.
4. 10.1111/trf.1286710.1111/trf.12867 ↗
5. 10.1046/j.1537-2995.2000.40081007.x10.1046/j.1537-2995.2000.40081007.x ↗
6. 10.1111/j.1423-0410.2008.01117.x10.1111/j.1423-0410.2008.01117.x ↗
7. 10.1111/trf.1280410.1111/trf.12804 ↗
8. Brunskill SJ, Wilkinson KL, Doree C, et al. Transfusion of fresher versus older red blood cells for all conditions. Cochrane Database Syst Rev. 2015;5:CD010801.
9. 10.1016/j.lpm.2016.06.02510.1016/j.lpm.2016.06.025 ↗
10. 10.1111/j.1423-0410.2010.01441.x10.1111/j.1423-0410.2010.01441.x ↗
11. 10.1097/MOL.000000000000021810.1097/MOL.0000000000000218 ↗
12. 10.1103/PhysRevLett.98.18830210.1103/PhysRevLett.98.188302 ↗
13. 10.1529/biophysj.107.10450510.1529/biophysj.107.104505 ↗
14. 10.1242/jeb.100.1.510.1242/jeb.100.1.5 ↗
15. 10.1002/j.2040-4603.2016.tb00698.x10.1002/j.2040-4603.2016.tb00698.x ↗
16. 10.1021/am201352w10.1021/am201352w ↗
17. Nimmo JR. Porosity and pore size distribution. Encyclopedia of soils in the environment. London, Elsevier; 2004. P. 295–303.
18. 10.1177/030932471139880910.1177/0309324711398809 ↗
19. 10.1039/C5NR03662C10.1039/C5NR03662C ↗
20. 10.1016/j.surfrep.2005.08.00310.1016/j.surfrep.2005.08.003 ↗
21. 10.1038/nnano.2009.7710.1038/nnano.2009.77 ↗
22. 10.1016/S0006-3495(95)79897-610.1016/S0006-3495(95)79897-6 ↗
23. D'Alessandro A, Liumbruno G, Grazzini G, et al. Red blood cell storage: the story so far. Blood Transfus. 2010;8:82–88.
24. 10.1097/ALN.0b013e318272d86610.1097/ALN.0b013e318272d866 ↗
25. 10.1159/00015522110.1159/000155221 ↗
26. 10.1155/2015/96830210.1155/2015/968302 ↗
27. 10.1097/00130478-200301000-0001310.1097/00130478-200301000-00013 ↗
28. 10.1016/j.cis.2017.05.01110.1016/j.cis.2017.05.011 ↗
29. 10.1016/j.ymeth.2013.03.03710.1016/j.ymeth.2013.03.037 ↗
30. 10.1016/j.micron.2007.06.01110.1016/j.micron.2007.06.011 ↗
31. 10.1016/S0006-3495(96)79602-910.1016/S0006-3495(96)79602-9 ↗
32. 10.1038/nnano.2007.38810.1038/nnano.2007.388 ↗
33. 10.1016/j.micron.2009.08.01110.1016/j.micron.2009.08.011 ↗
34. 10.1016/S0927-7765(00)00145-410.1016/S0927-7765(00)00145-4 ↗
35. 10.1002/cyto.a.1005210.1002/cyto.a.10052 ↗
36. 10.1007/s10439-005-3555-310.1007/s10439-005-3555-3 ↗
37. 10.1016/j.jbbm.2005.11.00310.1016/j.jbbm.2005.11.003 ↗
38. 10.1039/C5NR03145A10.1039/C5NR03145A ↗
39. 10.1002/jmr.217010.1002/jmr.2170 ↗
40. 10.1016/j.colsurfb.2006.03.00210.1016/j.colsurfb.2006.03.002 ↗
41. 10.1016/j.jbiomech.2010.11.00810.1016/j.jbiomech.2010.11.008 ↗
42. 10.1016/j.bbrc.2009.12.13310.1016/j.bbrc.2009.12.133 ↗
43. Lekka M, Fornal M, Pyka-Fościak G, et al. Erythrocyte stiffness probed using atomic force microscope. Biorheology. 2005;42:307–317.
44. Lamzin IM, Khayrullin RM. The quality assessment of stored red blood cells probed using atomic-force microscopy. Anat Res Int. 2014;2014:869683.
45. 10.1007/s11427-012-4399-310.1007/s11427-012-4399-3 ↗
46. 10.1111/trf.1336410.1111/trf.13364 ↗
47. Skardal A, Murphy SV, Devarasetty M, et al. Multi-tissue interactions in an integrated three-tissue organ-on-a-chip platform. Sci Rep. 2017;8:1–16.
48. 10.4137/ACI.S2890510.4137/ACI.S28905 ↗
49. 10.1016/j.mee.2018.11.00110.1016/j.mee.2018.11.001 ↗
50. 10.1016/j.jcmgh.2017.12.01010.1016/j.jcmgh.2017.12.010 ↗
51. 10.1146/annurev.biophys.36.040306.13264610.1146/annurev.biophys.36.040306.132646 ↗
52. 10.1016/j.bios.2014.07.02910.1016/j.bios.2014.07.029 ↗
53. 10.1007/s10544-005-6070-210.1007/s10544-005-6070-2 ↗
54. 10.1007/s10544-014-9834-810.1007/s10544-014-9834-8 ↗