journal article·2017-05-19Open access

Development of a novel biosensor based on a polypyrrole–dodecylbenzene sulphonate (PPy–DBS) film for the determination of amperometric cholesterol

Bayram Oğuz Özer, Servet Çete

Abstract

Herein a novel amperometric biosensor based on a conducting polymer with anionic dopant modified electrode was successfully developed for detection of cholesterol. Polypyrrole is deposited on a platinum surface and the sodium dodecylbenzene sulphonate (DBS) ion-doped polypyrrole film was electrochemically prepared by scanning the electrode potential between -0.8 and +0.8 V at a scan rate of 20 mV/s. The present electrochemical biosensor was optimized in terms of working potential, number of cycles, concentrations of monomer, and anionic dopant. Cholesterol oxidase (ChOx) was physically entrapped in PPy-DBS to construct an amperometric cholesterol biosensor. Amperometric determination is based on the electrochemical detection of H2O2 generated in the enzymatic reaction of cholesterol. Kinetic parameters, operational and storage stabilities, pH, and temperature dependencies were determined. Km and Imax were calculated as 0.11 μM and 0.967 nM/min, respectively. The operational stability results showed that 90.0% of the response current was retained after 30 activity assays. Morphology of electrodes was characterized by SEM and AFM. Additionally, contact angle measurements were made with 1 μL water of polymer film and enzyme electrode. As a result, the cholesterol biosensor suggested in this study is easy to prepare and is highly cost-effective. This composite (PPy-DBS) can supply a biocompatible and electrochemical microenvironment for immobilization of the enzyme, making this material a good candidate for the fabrication of highly sensitive and selective cholesterol biosensors.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Analytical Chemistry and Sensors · Conducting polymers and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Chemistry, Institute of Science, Gazi University

Department of Chemistry, Faculty of Science, Gazi University

References (51)

Show source-provided references
1. 10.1002/elan.20090036310.1002/elan.200900363 ↗
2. 10.1021/jp908949710.1021/jp9089497 ↗
3. 10.1016/j.snb.2012.05.02710.1016/j.snb.2012.05.027 ↗
4. 10.1016/j.bios.2011.05.01110.1016/j.bios.2011.05.011 ↗
5. 10.1016/j.elecom.2008.06.00310.1016/j.elecom.2008.06.003 ↗
6. 10.1016/j.bios.2007.10.01810.1016/j.bios.2007.10.018 ↗
7. 10.1016/j.ab.2007.01.02910.1016/j.ab.2007.01.029 ↗
8. 10.1016/j.bioelechem.2006.05.00610.1016/j.bioelechem.2006.05.006 ↗
9. 10.1016/S0302-4598(01)00105-210.1016/S0302-4598(01)00105-2 ↗
10. 10.1016/S0003-2670(01)01321-610.1016/S0003-2670(01)01321-6 ↗
11. 10.3109/21691401.2012.75912110.3109/21691401.2012.759121 ↗
12. 10.1080/1073119060068411610.1080/10731190600684116 ↗
13. 10.1080/1073119070137863410.1080/10731190701378634 ↗
14. 10.1016/0003-2670(95)00311-810.1016/0003-2670(95)00311-8 ↗
15. 10.4236/ajac.2010.1200610.4236/ajac.2010.12006 ↗
16. 10.3109/10731199.2011.64641010.3109/10731199.2011.646410 ↗
17. Feng B, Liu YN. 2015. A disposable cholesterol enzyme biosensor based on ferrocene-capped gold nanoparticle modified screen-printed carbon electrode. Int J Electrochem Sci. 10:4770–4778.10.1016/S1452-3981(23)06663-4 ↗
18. 10.1016/j.bios.2013.09.07410.1016/j.bios.2013.09.074 ↗
19. Gorgulu M, Cete S, Arslan H, Yasar A. 2013. Preparing a new biosensor for hypoxanthine determination by immobilization of xanthine oxidase and uricase in polypyrrole–polyvinyl sulphonate film. Artif Cells Blood Subst Biotechnol. 41:327–331.
20. 10.1016/S0013-4686(00)00644-710.1016/S0013-4686(00)00644-7 ↗
21. Guiseppi-Elie A, Wallace GG, Matsue T. 1995. In: Skotheim T, Elsenbaumer R, Reynolds JR, Eds. Handbook of Conductive Polymers. New York: Marcel Dekker.
22. 10.1016/0925-4005(93)85038-C10.1016/0925-4005(93)85038-C ↗
23. 10.1016/j.aca.2008.04.01010.1016/j.aca.2008.04.010 ↗
24. 10.1016/S0956-5663(99)00063-910.1016/S0956-5663(99)00063-9 ↗
25. 10.1016/0003-2670(94)85101-810.1016/0003-2670(94)85101-8 ↗
26. 10.1021/la702123a10.1021/la702123a ↗
27. 10.1016/j.msec.2008.08.04010.1016/j.msec.2008.08.040 ↗
28. 10.3109/1073119090335645310.3109/10731190903356453 ↗
29. 10.1093/clinchem/43.9.162210.1093/clinchem/43.9.1622 ↗
30. 10.1093/clinchem/46.3.43610.1093/clinchem/46.3.436 ↗
31. 10.1016/j.talanta.2015.03.02910.1016/j.talanta.2015.03.029 ↗
32. 10.1016/S0956-5663(01)00208-110.1016/S0956-5663(01)00208-1 ↗
33. 10.1016/0003-2670(96)00134-110.1016/0003-2670(96)00134-1 ↗
34. 10.1063/1.355376510.1063/1.3553765 ↗
35. 10.1016/j.aca.2003.09.06410.1016/j.aca.2003.09.064 ↗
36. 10.1016/j.aca.2005.10.00810.1016/j.aca.2005.10.008 ↗
37. 10.1016/j.talanta.2013.10.00710.1016/j.talanta.2013.10.007 ↗
38. 10.1016/j.snb.2013.03.00910.1016/j.snb.2013.03.009 ↗
39. 10.1016/j.colsurfb.2013.07.01310.1016/j.colsurfb.2013.07.013 ↗
40. 10.1039/C3AY41812J10.1039/C3AY41812J ↗
41. 10.1016/j.msec.2008.04.01010.1016/j.msec.2008.04.010 ↗
42. 10.1002/elan.20080429610.1002/elan.200804296 ↗
43. 10.1016/j.snb.2008.10.01610.1016/j.snb.2008.10.016 ↗
44. 10.1016/j.elecom.2008.10.04610.1016/j.elecom.2008.10.046 ↗
45. 10.1016/j.snb.2003.12.03610.1016/j.snb.2003.12.036 ↗
46. 10.1002/elan.114007020910.1002/elan.1140070209 ↗
47. 10.3390/s9080643510.3390/s90806435 ↗
48. 10.1021/ac011290k10.1021/ac011290k ↗
49. 10.1016/j.bios.2006.08.03810.1016/j.bios.2006.08.038 ↗
50. 10.1016/j.ab.2008.08.02210.1016/j.ab.2008.08.022 ↗
51. 10.1021/ac060549210.1021/ac0605492 ↗