journal article·2013-10Open access

Preparing a new biosensor for hypoxanthine determination by immobilization of xanthine oxidase and uricase in polypyrrole-polyvinyl sulphonate film

Mustafa Görgülü, Servet Çete, Halit Arslan, Ahmet Yaşar

Abstract

In this study, a new amperometric biosensor for the determination of hypoxanthine was developed. To this aim, polypyrrole-polyvinyl sulphonate films were prepared on the platinum electrode by the electropolymerization of pyrrole in the presence of polyvinyl sulphonate. Xanthine oxidase and uricase enzymes were immobilized in polypyrrole-polyvinyl sulphonate via the entrapment method. Optimum conditions of enzyme electrode were determined. Hypoxanthine detection is based on the oxidation of hydrogen peroxide at +400 mV produced by the enzymatic reaction on the enzyme electrode surface. The linear working range of biosensor for hypoxanthine was determined. The effects of pH and temperature on the response of the hypoxanthine biosensor were investigated. Optimum pH and temperature were measured as 8 and 30°C, respectively. Operational and storage stability of the biosensor were determined. After 20 assays, the biosensor sustained 74.5% of its initial performance. After 33 days, the biosensor lost 36% of its initial performance. The performance of the biosensor was tested in real samples.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Gout, Hyperuricemia, Uric Acid · Adipose Tissue and Metabolism

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (22)

Show source-provided references
1. Acevedo-Chavez R · J Mol Struct (Theoche) · 1999 · 489 · 7310.1016/S0166-1280(99)00049-4 ↗
2. Acevedo-Chavez R · J Mol Struct (Theochem) · 2000 · 499 · 7110.1016/S0166-1280(99)00278-X ↗
3. Adeloju SB · J Mol Catal B Enzymat · 2010 · 66 · 27010.1016/j.molcatb.2010.06.002 ↗
4. Altarsha M · Bioorg Chem · 2009 · 37 · 11110.1016/j.bioorg.2009.05.004 ↗
5. Amine A · Biosens Bioelectron · 2006 · 21 · 140510.1016/j.bios.2005.07.012 ↗
6. Anık Ü · Talanta · 2007 · 74 · 43410.1016/j.talanta.2007.07.039 ↗
7. Arkhypova VN · ITBM-RBM · 2008 · 29 · 171
8. Bhushan B · Biochem Biophys Res Commun · 2003 · 306 · 50910.1016/S0006-291X(03)01001-5 ↗
9. Choi MF · Biosens Bioelectron · 2007 · 22 · 179110.1016/j.bios.2006.08.038 ↗
10. Chubey A · Sens Actuators · 2000 · 46 · 723
11. Cosnier S · Biosens Bioelectron · 2008 · 24 · 105310.1016/j.bios.2008.07.052 ↗
12. Cui D · Anal Chim Acta · 2000 · 412 · 5510.1016/S0003-2670(00)00748-0 ↗
13. Fernandez-Quejon M · J Mol Struct · 2005 · 744 · 74910.1016/j.molstruc.2004.10.092 ↗
14. Frederiks WM · Acta Histochem · 2002 · 104 · 2910.1078/0065-1281-00629 ↗
15. Ghosh S · Sens Actuators B · 1998 · 53 · 5810.1016/S0925-4005(98)00285-8 ↗
16. İnem B · J Fac Eng Arch Gazi Univ · 2010 · 25 · 235
17. Leszczynski J · J Mol Struct (Theochem) · 2000 · 529 · 9910.1016/S0166-1280(00)00523-6 ↗
18. Mallavia R · Biosens Bioelectron · 2008 · 24 · 105310.1016/j.bios.2008.07.052 ↗
19. Okuma H · Biosens Bioelectron · 2002 · 17 · 36710.1016/S0956-5663(01)00309-8 ↗
20. Qiong C · Anal Chim Acta · 1998 · 369 · 24510.1016/S0003-2670(98)00213-X ↗
21. Singh S · Anal Chim Acta · 2007 · 582 · 33510.1016/j.aca.2006.09.010 ↗
22. White DC, White JS. 1997. Source Book Enzyme. Boca Raton: CRC Press, 85–82, 129–132.