Recent approaches to ameliorate selectivity and sensitivity of enzyme based cholesterol biosensors: a review
Source abstract
Abstract
The healthcare area is often reluctant to execute new technology unless they are proven to be safe, constructive and secure. Eventually, an aspiration stands for providing point-of-care testing service to allow a better estimation of the biochemical levels of a patient that entails an insistent remedial action. With increasing mortality rate due to cardiovascular diseases (CVDs) in present scenario, it has become the need of hour to develop more advance methods for their diagnosis, so that it can be determined at sensitive levels and can be prevented from being fatal. Elevated level of cholesterol in blood stream is one of the utmost risk factors which lead to CVDs. Discernible from the vast research in this field, worth of cholesterol biosensors is already recognized and flourished in the clinical analysis of brain and cardiac vascular diseases. It necessitates unremitting progress in the development of biosensing technology towards fabrication, miniaturization and multiplexing ability of cholesterol quantification devices so that they can endow with lab-on-chip-analysis systems to the medical field. Different strategies have been meticulously explored for the engineering of cholesterol biosensors utilizing nanocomposites, conducting polymers, nanotubes and nanoparticles. Foremost, this article reviews the contemporary evolution in cholesterol biosensors, which encompass various strategies for immobilization of enzymes and roles of various matrices and artificial mediators used for the biosensor fabrication. Still there remains an enormous challenge to congregate the demands of performance and yield in a cost effective manner for its application in successful treatments of CVDs.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Electrochemical sensors and biosensors · Advanced biosensing and bioanalysis techniques · Enzyme Catalysis and Immobilization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Centre for Biotechnology, Maharshi Dayanand University, Rohtak, India
References (90)
Show source-provided references
1. 10.1146/annurev.me.31.020180.00052510.1146/annurev.me.31.020180.000525 ↗
2. 10.1007/3-540-27661-0_610.1007/3-540-27661-0_6 ↗
3. 10.4082/kjfm.2012.33.4.22910.4082/kjfm.2012.33.4.229 ↗
4. 10.1093/clinchem/45.12.215810.1093/clinchem/45.12.2158 ↗
5. 10.1016/S0165-022X(98)00036-010.1016/S0165-022X(98)00036-0 ↗
6. 10.1021/ac60204a06610.1021/ac60204a066 ↗
7. 10.1093/clinchem/20.4.47010.1093/clinchem/20.4.470 ↗
8. 10.1093/clinchem/27.12.197810.1093/clinchem/27.12.1978 ↗
9. Gahlaut A · Int J Appl Biotechnol Biochem · 2012 · 2 · 185
10. Bhatia D · Indian J Biotechnol · 2005 · 4 · 471
11. Vikas A · Sensors Transducers J · 2007 · 76 · 935
12. Kroger S · 1997 · 279
13. Lawrence CR · 1997 · 149
14. 10.1016/j.rbmret.2007.11.00710.1016/j.rbmret.2007.11.007 ↗
15. 10.3923/jpt.2006.566.57210.3923/jpt.2006.566.572 ↗
16. 10.1016/j.cca.2006.03.03010.1016/j.cca.2006.03.030 ↗
17. 10.1007/978-90-481-8622-8_510.1007/978-90-481-8622-8_5 ↗
18. Vahouny GV · Methods Biochem Anal · 1968 · 16 · 21910.1002/9780470110348.ch4 ↗
19. 10.1016/0003-2670(91)87006-S10.1016/0003-2670(91)87006-S ↗
20. 10.1002/elan.114009090210.1002/elan.1140090902 ↗
21. 10.1039/B711564B10.1039/B711564B ↗
22. 10.1016/j.bej.2009.07.01710.1016/j.bej.2009.07.017 ↗
23. 10.1016/j.biotechadv.2011.09.00310.1016/j.biotechadv.2011.09.003 ↗
24. 10.2174/18722120878630633310.2174/187221208786306333 ↗
25. Singh BD · 2009
26. 10.1007/s13205-012-0071-710.1007/s13205-012-0071-7 ↗
27. Wang X, Uchiyama S. Polymers for biosensors construction. “State of the Art in Biosensors - General Aspects”, ISBN 978-953-51-1004-0, Published: March 13, 2013.
28. 10.1016/j.aca.2003.09.06410.1016/j.aca.2003.09.064 ↗
29. 10.2116/analsci.18.53710.2116/analsci.18.537 ↗
30. 10.1002/app.221010.1002/app.2210 ↗
31. 10.3390/s9030179410.3390/s90301794 ↗
32. Chauhan RPS · J Biosens Bioelectron · 2013 · 62 · 493
33. 10.1016/j.enzmictec.2003.12.01310.1016/j.enzmictec.2003.12.013 ↗
34. 10.1016/j.elecom.2008.10.04610.1016/j.elecom.2008.10.046 ↗
35. 10.1016/j.talanta.2013.02.00210.1016/j.talanta.2013.02.002 ↗
36. 10.1039/c2an36075f10.1039/c2an36075f ↗
37. 10.1016/j.snb.2008.09.04710.1016/j.snb.2008.09.047 ↗
38. 10.1039/c1gc15178a10.1039/c1gc15178a ↗
39. 10.1002/elan.20039012410.1002/elan.200390124 ↗
40. 10.1016/j.aca.2006.09.01010.1016/j.aca.2006.09.010 ↗
41. 10.3390/s10020121610.3390/s100201216 ↗
42. Hooda V · Int J Biotechnol Biochem · 2011 · 7 · 617
43. Hooda V · J Scient Indust Res · 2008 · 67 · 299
44. 10.1111/j.0919-9268.2003.00745.x10.1111/j.0919-9268.2003.00745.x ↗
45. 10.1155/2009/84257510.1155/2009/842575 ↗
46. 10.1039/C1AN15196G10.1039/C1AN15196G ↗
47. 10.1016/j.talanta.2012.05.05610.1016/j.talanta.2012.05.056 ↗
48. 10.1016/j.bioelechem.2006.05.00610.1016/j.bioelechem.2006.05.006 ↗
49. 10.1016/0302-4598(96)05078-710.1016/0302-4598(96)05078-7 ↗
50. 10.1016/j.biotechadv.2004.03.00410.1016/j.biotechadv.2004.03.004 ↗
51. 10.1016/j.bios.2010.07.10110.1016/j.bios.2010.07.101 ↗
52. Norouzi P · Int J Electrochem Sci · 2010 · 5 · 100810.1016/S1452-3981(23)15339-9 ↗
53. Jeng-You Y · Int J Electrochem Sci · 2011 · 6 · 222310.1016/S1452-3981(23)18179-X ↗
54. 10.1002/elan.20050341510.1002/elan.200503415 ↗
55. 10.1016/j.bios.2011.05.01110.1016/j.bios.2011.05.011 ↗
56. Parviz N · Anal Bioanal Electrochem · 2012 · 4 · 70
57. Qiao CS · Chinese Chem Lett · 2005 · 16 · 1081
58. 10.1016/j.bios.2010.12.00910.1016/j.bios.2010.12.009 ↗
59. 10.1016/j.bios.2011.12.00810.1016/j.bios.2011.12.008 ↗
60. 10.1166/sam.2012.125610.1166/sam.2012.1256 ↗
61. Baby TT, Ramaprabhu S. Non-enzymatic glucose and cholesterol biosensors based on silica coated nano iron oxide dispersed multiwalled carbon nanotubes, nanoscience, technology and societal implications (NSTSI), 2011.10.1109/NSTSI.2011.6111981 ↗
62. 10.1002/elan.20120059110.1002/elan.201200591 ↗
63. Dey RS · J Phys Chem · 2010 · 114 · 21427
64. 10.1016/j.talanta.2008.11.01810.1016/j.talanta.2008.11.018 ↗
65. 10.1016/j.aca.2008.04.01010.1016/j.aca.2008.04.010 ↗
66. 10.1016/j.talanta.2012.03.03710.1016/j.talanta.2012.03.037 ↗
67. 10.1016/j.tsf.2010.08.05210.1016/j.tsf.2010.08.052 ↗
68. 10.1016/j.bios.2004.09.00510.1016/j.bios.2004.09.005 ↗
69. Saini D · Int Sch Res Notices · 2012 · 2012
70. 10.1021/ac001224310.1021/ac0012243 ↗
71. 10.1016/j.talanta.2013.02.00210.1016/j.talanta.2013.02.002 ↗
72. 10.1016/j.snb.2013.03.00910.1016/j.snb.2013.03.009 ↗
73. Dervisevic M, Cevik E, Senel M, et al. Amperometric cholesterol biosensor based on reconstituted cholesterol oxidase on boronic acid functional conducting polymers. J Electroanalyt Chem. 2016;776:18–24.10.1016/j.jelechem.2016.06.033 ↗
74. Soylemez S, Udum YA, Kesik M, et al. Electrochemical and optical properties of a conducting polymer and its use in a novel biosensor for the detection of cholesterol. Sens Actuats B Chem. 2015;212:425–433.10.1016/j.snb.2015.02.045 ↗
75. Cardosi MF · 1990 · 125
76. 10.1016/S0956-5663(01)00313-X10.1016/S0956-5663(01)00313-X ↗
77. 10.1039/an994190233110.1039/an9941902331 ↗
78. 10.1016/0003-2670(95)00311-810.1016/0003-2670(95)00311-8 ↗
79. 10.1021/ac960996p10.1021/ac960996p ↗
80. 10.1021/ac980545010.1021/ac9805450 ↗
81. 10.1021/ac990801o10.1021/ac990801o ↗
82. 10.1016/j.ab.2004.06.00510.1016/j.ab.2004.06.005 ↗
83. 10.1016/j.snb.2014.05.11410.1016/j.snb.2014.05.114 ↗
84. 10.1021/la700350x10.1021/la700350x ↗
85. Solanki PR · J Biomed Pharm Eng · 2008 · 2 · 7
86. 10.1016/j.bios.2008.11.03410.1016/j.bios.2008.11.034 ↗
87. 10.1016/S0956-5663(97)85341-910.1016/S0956-5663(97)85341-9 ↗
88. 10.1002/bit.2314310.1002/bit.23143 ↗
89. 10.1016/j.bios.2014.01.04610.1016/j.bios.2014.01.046 ↗
90. 10.1016/j.bios.2015.11.04210.1016/j.bios.2015.11.042 ↗