Effects of poly(acrylic acid)’s crosslinker content on pulmonary toxicity in rats
Source abstract
Abstract
For many years, poly(acrylic acid) (PAA) was considered an almost perfectly safe material, but in 2017, reports surfaced of pulmonary toxicity in workers who had handled crosslinked PAA particles at a Japanese factory. To elucidate the chemical compositions and physical properties that are responsible for the PAA's pulmonary toxicity and to design safer PAA materials, we synthesized four PAAs for the present study by chemically analyzing a PAA's crosslinker, performing a diameter measurement of a commercial PAA product, and then varying the PAA's crosslinker content. All the four synthesized PAAs were associated with inflammatory responses and fibrosis formation in rats through a single intratracheal administration of the PAAs, and the crosslinker content was revealed to be an important factor contributing to serious inflammation and long-lasting fibrosis in the lungs.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Inhalation and Respiratory Drug Delivery · Intravenous Infusion Technology and Safety · Advanced Chemical Sensor Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Division of Medical Engineering, Research Center for Medical Sciences, the Jikei University School of Medicine
Department of Public Health and Environmental Medicine, the Jikei University School of Medicine
The Jikei University School of Medicine
Funding
Ministry of Education, Culture, Sports, Science and Technology
References (32)
Show source-provided references
1. Ministry of Health Labour and Welfare of Japan. Alert notice about incidence of lung diseases among workers handling cross-linked water-soluble acrylic acid polymer in a chemical factory; 2017. https://www.mhlw.go.jp/stf/houdou/0000163568.html. [cited 2024 June 10]. Japanese.
2. Ministry of Health Labour and Welfare of Japan. Committee report on lung diseases among workers handling cross-linked water-soluble acrylic acid polymer in a chemical factory; 2019. (published on April 19 2019) https://www.mhlw.go.jp/stf/shingi/other-roudou_128880_00004.html. [cited 2024 June 10]. Japanese.
3. 10.1016/s0140-6736(94)91896-110.1016/s0140-6736(94)91896-1 ↗
4. 10.1136/oem.54.6.37610.1136/oem.54.6.376 ↗
5. 10.1093/toxsci/52.2.20910.1093/toxsci/52.2.209 ↗
6. 10.1006/taap.2001.924710.1006/taap.2001.9247 ↗
7. 10.1007/s00204-015-1486-910.1007/s00204-015-1486-9 ↗
8. 10.1164/rccm.201404-0710LE10.1164/rccm.201404-0710LE ↗
9. 10.3390/ijerph1811613610.3390/ijerph18116136 ↗
10. 10.1002/jat.255014040510.1002/jat.2550140405 ↗
11. 10.1002/jat.255015011510.1002/jat.2550150115 ↗
12. 10.1016/j.tox.2020.15264710.1016/j.tox.2020.152647 ↗
13. 10.1186/s12989-022-00448-z10.1186/s12989-022-00448-z ↗
14. 10.3390/ijms23181034510.3390/ijms231810345 ↗
15. 10.1002/1348-9585.1236910.1002/1348-9585.12369 ↗
16. 10.1186/s12989-022-00468-910.1186/s12989-022-00468-9 ↗
17. 10.3390/ijms23221387010.3390/ijms232213870 ↗
18. 10.1186/s12931-023-02355-z10.1186/s12931-023-02355-z ↗
19. 10.1371/journal.pone.028483710.1371/journal.pone.0284837 ↗
20. 10.1007/s13726-015-0373-910.1007/s13726-015-0373-9 ↗
21. 10.1111/imm.1303310.1111/imm.13033 ↗
22. 10.1111/imm.1345210.1111/imm.13452 ↗
23. 10.1289/ehp.845536910.1289/ehp.8455369 ↗
24. 10.1089/jamp.2010.083610.1089/jamp.2010.0836 ↗
25. 10.1089/jamp.2017.138210.1089/jamp.2017.1382 ↗
26. 10.3390/pharmaceutics1301003110.3390/pharmaceutics13010031 ↗
27. 10.1152/jappl.1998.85.2.37910.1152/jappl.1998.85.2.379 ↗
28. 10.4155/tde-2017-003710.4155/tde-2017-0037 ↗
29. 10.1016/j.biopha.2019.10860110.1016/j.biopha.2019.108601 ↗
30. 10.1016/j.ejpb.2016.12.02210.1016/j.ejpb.2016.12.022 ↗
31. 10.1016/s0168-3659(00)00216-910.1016/s0168-3659(00)00216-9 ↗
32. 10.1021/bm034028p10.1021/bm034028p ↗