Exploring the mechanical behavior of the spinal dura mater: experimental insights and measurement dilemmas
Source abstract
Abstract
Abstract Spinal dura mater provides essential structural protection for the spinal cord and helps maintain cerebrospinal fluid pressure, yet its mechanical characterization remains challenging because of its thinness and anisotropy. This study investigated the uniaxial tensile behavior of spinal dura mater and examined how speckle-paint application, the strain-measurement method (Digital Image Correlation (DIC)-derived strain vs. crosshead displacement), preconditioning, and donor demographics affect measured mechanical parameters. Samples were harvested postmortem from seven donors and assigned to three groups: painted & not preconditioned, unpainted & preconditioned, and unpainted & not preconditioned. A 3D-printed adapter was used to standardize sample geometry. Tests were conducted at a crosshead displacement rate of 5 mm·min⁻¹ (strain rate of 0.0042 s⁻¹), with some specimens undergoing cyclic preloading. Speckle paint increased stiffness but did not affect failure stress or stretch. DIC-derived elastic moduli were higher than those from crosshead displacement. After correcting for paint- and method-induced effects, the mean elastic moduli in the longitudinal and circumferential directions were ~ 283 MPa and ~ 16 MPa, respectively. Both orientations exhibited a failure stretch of ~ 1.10–1.12. The apparent Poisson function (Hencky form) ranged from 1.57 to 4.84 (longitudinal) and 2.91 to 6.29 (circumferential), indicating volumetric changes that challenge near-incompressibility assumptions. These findings emphasize the importance of standardized protocols and data normalization when investigating soft tissue mechanics. The higher DIC-based moduli arise primarily from local, gauge-region strain measurement and stiffening induced by the acrylic speckle coating, while the elevated apparent Poisson’s ratios likely reflect fluid redistribution and collagen-fiber reorientation under tensile loading in this highly anisotropic tissue.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Cerebrospinal fluid and hydrocephalus · Spine and Intervertebral Disc Pathology · Automotive and Human Injury Biomechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (59)
Show source-provided references
1. Ünal M, Sezgin AB. Dura mater: anatomy and clinical implication. J Behav Brain Sci. 2021;11:239–47. https://doi.org/10.4236/jbbs.2021.1110019.10.4236/jbbs.2021.1110019 ↗
2. Gray H. Gray’s anatomy: the anatomical basis of clinical practice. 42nd ed. Philadelphia: Elsevier; 2020.
3. Szotek S, Dawidowicz J, Geniusz M, Kozak M, Łukomski R Czogalla A. The Biomechanical characteristics of spinal dura mater in the context of its basic morphology Acta Bioeng Biomech 2021. https://doi.org/10.37190/ABB-01972-2021-02.10.37190/ABB-01972-2021-02 ↗
4. Nagel SJ, Reddy CG, Frizon LA, Chardon MK, Holland M, Machado AG, et al. Spinal dura mater: biophysical characteristics relevant to medical device development. J Med Eng Technol. 2018;42:128–39. https://doi.org/10.1080/03091902.2018.1435745.10.1080/03091902.2018.1435745 ↗
5. Pearcy Q, Tomlinson J, Niestrawska JA, Möbius D, Zhang M, Zwirner J. Systematic review and meta-analysis of the Biomechanical properties of the human dura mater applicable in computational human head models. Biomech Model Mechanobiol. 2022;21:755–70. https://doi.org/10.1007/s10237-022-01566-5.10.1007/s10237-022-01566-5 ↗
6. Zhang Z-D, Zhao L-Y, Liu Y-R, Zhang J-Y, Xie S-H, Lin Y-Q et al Absorbable artificial dura versus nonabsorbable artificial dura in decompressive craniectomy for severe traumatic brain injury: a retrospective cohort study in two centers. Front Surg. 2022. . https://doi.org/10.3389/fsurg.2022.877038.10.3389/fsurg.2022.877038 ↗
7. Dong R-P, Zhang Q, Yang L-L, Cheng X-L, Zhao J-W. Clinical management of dural defects: A review. World J Clin Cases. 2023;11:2903–15. https://doi.org/10.12998/wjcc.v11.i13.2903.10.12998/wjcc.v11.i13.2903 ↗
8. Yudoyono F, Pebrianto A. Dural tear with multiple nerve root entrapment simultaneously after unstable spine injury. Neurologico Spinale Medico Chirurgico. 2021;4:7–10. https://doi.org/10.36444/nsmc.v4i1.134.10.36444/nsmc.v4i1.134 ↗
9. Maikos JT, Elias RAI, Shreiber DI. Mechanical properties of dura mater from the rat brain and spinal cord. J Neurotrauma. 2008;25:38–51. https://doi.org/10.1089/neu.2007.0348.10.1089/neu.2007.0348 ↗
10. van Noort R, Martin TRP, Black MM, Barker AT, Montero CG. The mechanical properties of human dura mater and the effects of storage media. Clin Phys Physiol Meas. 1981;2:197–203. https://doi.org/10.1088/0143-0815/2/3/003.10.1088/0143-0815/2/3/003 ↗
11. Zwirner J, Scholze M, Waddell JN, Ondruschka B, Hammer N. Mechanical properties of human dura mater in Tension – An analysis at an age range of 2 to 94 years. Sci Rep. 2019;9:16655. https://doi.org/10.1038/s41598-019-52836-9.10.1038/s41598-019-52836-9 ↗
12. Wiczenbach T, Wolny R, Bruski D, Daszkiewicz K, Kolczyk W, Spodnik JH et al Mechanical properties of human spinal dura mater show rate dependency Sci Rep. 2025. https://doi.org/10.1038/s41598-025-08471-8.10.1038/s41598-025-08471-8 ↗
13. Shetye SS, Deault MM, Puttlitz CM. Biaxial response of ovine spinal cord dura mater. J Mech Behav Biomed Mater. 2014;34:146–53. https://doi.org/10.1016/j.jmbbm.2014.02.014.10.1016/j.jmbbm.2014.02.014 ↗
14. Tamura A, Nishikawa S Dural mechanical responses to Load-Controlled asymmetric biaxial stretch. J Mech Med Biol. 2023. https://doi.org/10.1142/S021951942350077X.10.1142/S021951942350077X ↗
15. PierratB, Carroll L, Merle F, MacManus DB, Gaul R, Lally C, et al. Mechanical characterization and modeling of the Porcine cerebral meninges. Front Bioeng Biotechnol; 2020. https://doi.org/10.3389/fbioe.2020.0080110.3389/fbioe.2020.00801 ↗
16. MacManus DB, Pierrat B, Murphy JG, Gilchrist MD. Protection of cortex by overlying meninges tissue during dynamic indentation of the adolescent brain. Acta Biomater. 2017;57:384–94. https://doi.org/10.1016/j.actbio.2017.05.022.10.1016/j.actbio.2017.05.022 ↗
17. Jin C, Yu J, Li R, Ye X Regional Biomechanical characterization of the spinal cord tissue: dynamic mechanical response. Front Bioeng Biotechnol. 2024. https://doi.org/10.3389/fbioe.2024.1439323.10.3389/fbioe.2024.1439323 ↗
18. Kizmazoglu C, Aydin HE, Kaya I, Atar M, Husemoglu B, Kalemci O, et al Comparison of biomechanical properties of dura mater substitutes and cranial human dura mater: an in vitro study J Korean Neurosurg Soc. 2019;62:635–42. . . https://doi.org/10.3340/jkns.2019.0122.10.3340/jkns.2019.0122 ↗
19. Cavelier S, Quarrington RD, Jones CF. Tensile properties of human spinal dura mater and pericranium. J Mater Sci Mater Med. 2022;34:4. https://doi.org/10.1007/s10856-022-06704-0.10.1007/s10856-022-06704-0 ↗
20. Runza M, Pietrabissa R, Mantero S, Albani A, Quaglini V, Contro R. Lumbar dura mater biomechanics. Anesth Analg. 1999;88:1317–21. https://doi.org/10.1097/00000539-199906000-00022.10.1097/00000539-199906000-00022 ↗
21. Tencer AF, Allen BL, Ferguson RL. A Biomechanical study of thoracolumbar spine fractures with bone in the Canal. Spine (Phila Pa 1976). 1985;10:741–7. https://doi.org/10.1097/00007632-198510000-00009.10.1097/00007632-198510000-00009 ↗
22. Zarzur E. Mechanical properties of the human lumbar dura mater. Arq Neuropsiquiatr. 1996;54:455–60. https://doi.org/10.1590/S0004-282X1996000300015.10.1590/S0004-282X1996000300015 ↗
23. Bigger R, Blaysat B, Boo C, Grewer M, Hu J, Jones A et al. A good practices guide for digital image correlation. 2018. https://doi.org/10.32720/idics/gpg.ed1/print.format.10.32720/idics/gpg.ed1/print.format ↗
24. Bai P, Zhu F, He X. Optical extensometer and elimination of the effect of out-of-plane motions. Opt Lasers Eng. 2015;65:28–37. https://doi.org/10.1016/j.optlaseng.2014.04.010.10.1016/j.optlaseng.2014.04.010 ↗
25. Genovese K, Badel P, Cavinato C, Pierrat B, Bersi MR, Avril S, et al. Multi-view digital image correlation systems for in vitro testing of arteries from mice to humans. Exp Mech. 2021;61:1455–72. https://doi.org/10.1007/s11340-021-00746-1.10.1007/s11340-021-00746-1 ↗
26. Nowak M, Maj M. Determination of coupled mechanical and thermal fields using 2D digital image correlation and infrared thermography: numerical procedures and results. Archives Civil Mech Eng. 2018;18:630–44. https://doi.org/10.1016/j.acme.2017.10.005.10.1016/j.acme.2017.10.005 ↗
27. Musiał S, Nowak M, Maj M. Stress field determination based on digital image correlation results. Archives Civil Mech Eng. 2019;19:1183–93. https://doi.org/10.1016/j.acme.2019.06.007.10.1016/j.acme.2019.06.007 ↗
28. Dzaye ED, Tsangouri E, Spiessens K, De Schutter G, Aggelis DG. Digital image correlation (DIC) on fresh cement mortar to quantify settlement and shrinkage. Archives Civil Mech Eng. 2019;19:205–14. https://doi.org/10.1016/j.acme.2018.10.003.10.1016/j.acme.2018.10.003 ↗
29. Ziaja D, Jurek M, Śliwa R, Wiater A, Kulpa M. DIC application for damage detection in FRP composite specimens based on an example of a shearing test. Archives Civil Mech Eng. 2024;24:47. https://doi.org/10.1007/s43452-024-00859-z.10.1007/s43452-024-00859-z ↗
30. Zwirner J, Ondruschka B, Scholze M, Hammer N. Surface coating and speckling of the human iliotibial tract does not affect its load-deformation properties. Sci Rep. 2020;10:20747. https://doi.org/10.1038/s41598-020-77299-1.10.1038/s41598-020-77299-1 ↗
31. Liber-Kneć A, Łagan S. The effects of preconditioning on tensile properties of pig’s skin. Biomaterials in medicine and veterinary medicine: proceedings of the 27th annual conference of the polish society for biomaterials, Vol. iii, Rytro, Poland: engineering of biomaterials; 2018, p. 15.
32. Mattucci SFE, Moulton JA, Chandrashekar N, Cronin DS. Strain rate dependent properties of younger human cervical spine ligaments. J Mech Behav Biomed Mater. 2012;10:216–26. https://doi.org/10.1016/j.jmbbm.2012.02.004.10.1016/j.jmbbm.2012.02.004 ↗
33. Tonge TK, Murienne BJ, Coudrillier B, Alexander S, Rothkopf W Nguyen TD Minimal preconditioning effects observed for inflation tests of planar tissues. J Biomech Eng. 2013. https://doi.org/10.1115/1.4025105.10.1115/1.4025105 ↗
34. Mazgajczyk E, Ścigała K, Czyz M, Jarmundowicz W, Bȩdziński R. Mechanical properties of cervical dura mater. Acta Bioeng Biomech. 2012;14:51–8.
35. MihaiLA,Goriely A. How to characterize a nonlinear elastic material? A review on nonlinear constitutive parameters in isotropic finite elasticity. Proc R Soc A: Math Phys Eng Sci. 2017;473:20170607. https://doi.org/10.1098/rspa.2017.060710.1098/rspa.2017.0607 ↗
36. Maas SA, Ellis BJ, Ateshian GA, Weiss JA FEBio: finite elements for biomechanics. J Biomech Eng. 2012. https://doi.org/10.1115/1.4005694.10.1115/1.4005694 ↗
37. Cavelier S, Quarrington RD, Jones CF. Tensile properties of human spinal dura mater and pericranium. J Mater Sci Mater Med 2023. https://doi.org/10.1007/s10856-022-06704-010.1007/s10856-022-06704-0 ↗
38. Fung YC. Yuan-cheng). Biomechanics: mechanical properties of living tissues. 2nd ed. New York, NY, USA: Springer-Verlag New York, Inc.; 1993.10.1007/978-1-4757-2257-4 ↗
39. Holzapfel GA. Nonlinear solid mechanics: a continuum approach for engineering / Gerhard A. Holzapfel. 2005:489–90.10.1023/A:1020843529530 ↗
40. Wolny R, Wiczenbach T, Andrzejewska AJ, Spodnik JH Mechanical response of human thoracic spine ligaments under quasi-static loading: an experimental study. J Mech Behav Biomed Mater. 2024. https://doi.org/10.1016/j.jmbbm.2024.106404.10.1016/j.jmbbm.2024.106404 ↗
41. Mattucci SFE, Cronin DS. A method to characterize average cervical spine ligament response based on Raw data sets for implementation into injury biomechanics models. J Mech Behav Biomed Mater. 2015;41:251–60. https://doi.org/10.1016/j.jmbbm.2014.09.023.10.1016/j.jmbbm.2014.09.023 ↗
42. Marquardt DW. An algorithm for Least-Squares Estimation of nonlinear parameters. J Soc Ind Appl Math. 1963;11:431–41. https://doi.org/10.1137/0111030.10.1137/0111030 ↗
43. Levenberg K. A method for the solution of certain non-linear problems in least squares. Q Appl Math. 1944;2:164–8. https://doi.org/10.1090/qam/10666.10.1090/qam/10666 ↗
44. Altman DG. Practical statistics for medical research. Chapman and Hall/CRC; 1990. https://doi.org/10.1201/9780429258589.10.1201/9780429258589 ↗
45. Beatty MF, Stalnaker DO. The Poisson function of finite elasticity. J Appl Mech. 1986;53:807–13. https://doi.org/10.1115/1.3171862.10.1115/1.3171862 ↗
46. Morales-Avalos R, Soto-Domínguez A, García-Juárez J, Saucedo-Cardenas O, Bonilla-Galvan JR, Cardenas-Serna M, et al. Characterization and morphological comparison of human dura mater, temporalis fascia, and pericranium for the correct selection of an autograft in duraplasty procedures. Surg Radiol Anat. 2017;39:29–38. https://doi.org/10.1007/s00276-016-1692-z.10.1007/s00276-016-1692-z ↗
47. Wiczenbach T, Wolny R, Bruski D, Daszkiewicz K, Kolczyk W, Spodnik JH, et al. Mechanical properties of human spinal dura mater show rate dependency. Sci Rep. 2025;15:23511. https://doi.org/10.1038/s41598-025-08471-8.10.1038/s41598-025-08471-8 ↗
48. Szotek S, Dawidowicz J, Geniusz M, Kozak M, Łukomski R, Czogalla A. The Biomechanical characteristics of spinal dura mater in the context of its basic morphology. Acta Bioeng Biomech. 2021;23:149–59. https://doi.org/10.37190/ABB-01972-2021-02.10.37190/ABB-01972-2021-02 ↗
49. de Cassia Marqueti R, Vieira de Sousa Neto I, Reichert Barin F, Vieira Ramos G. Exercise and tendon remodeling mechanism. Tendons, IntechOpen; 2019. https://doi.org/10.5772/intechopen.7972910.5772/intechopen.79729 ↗
50. Kim J, Gardiner SK, Ramazzotti A, Karuppanan U, Bruno L, Girkin CA, et al. Strain by virtual extensometers and video-imaging optical coherence tomography as a repeatable metric for IOP-Induced optic nerve head deformations. Exp Eye Res. 2021;211:108724. https://doi.org/10.1016/j.exer.2021.108724.10.1016/j.exer.2021.108724 ↗
51. Hammer N, Ondruschka B, Berghold A, Kuenzer T, Pregartner G, Scholze M, et al. Sample size considerations in soft tissue biomechanics. Acta Biomater. 2023;169:168–78. https://doi.org/10.1016/j.actbio.2023.07.036.10.1016/j.actbio.2023.07.036 ↗
52. Jiang Y, Wang Y, Peng XA, Visco-Hyperelastic. Constitutive model for human spine ligaments. Cell Biochem Biophys. 2015;71:1147–56. https://doi.org/10.1007/s12013-014-0322-9.10.1007/s12013-014-0322-9 ↗
53. Østergaard MB, Hansen SR, Januchta K, To T, Rzoska SJ, Bockowski M, et al. Revisiting the dependence of poisson’s ratio on liquid fragility and atomic packing density in oxide glasses. Materials. 2019;12:2439. https://doi.org/10.3390/ma12152439.10.3390/ma12152439 ↗
54. Mott PH, Roland CM. Limits to poisson’s ratio in isotropic materials. Phys Rev B. 2009;80:132104. https://doi.org/10.1103/PhysRevB.80.132104.10.1103/PhysRevB.80.132104 ↗
55. Canelas HM, Aisen J, Jorge FB, De, Anghinah A. Biochemistry of the normal dura mater of the human brain determination of water, sodium, potassium, calcium, phosphorus, magnesium, copper, iron, sulfur and nitrogen contents. Arq Neuropsiquiatr. 1969;27:85–8. https://doi.org/10.1590/S0004-282X1969000200001.10.1590/S0004-282X1969000200001 ↗
56. Kohlhauser C, Hellmich C. Determination of poisson’s ratios in isotropic, transversely isotropic, and orthotropic materials by means of combined ultrasonic-mechanical testing of normal stiffnesses: application to metals and wood. Eur J Mech A Solids. 2012;33:82–98. https://doi.org/10.1016/j.euromechsol.2011.11.009.10.1016/j.euromechsol.2011.11.009 ↗
57. Vergari C, Pourcelot P, Holden L, Ravary-Plumioën B, Gerard G, Laugier P, et al. True stress and poisson’s ratio of tendons during loading. J Biomech. 2011;44:719–24. https://doi.org/10.1016/j.jbiomech.2010.10.038.10.1016/j.jbiomech.2010.10.038 ↗
58. Persson C, Evans S, Marsh R, Summers JL, Hall RM. Poisson’s ratio and strain rate dependency of the constitutive behavior of spinal dura mater. Ann Biomed Eng. 2010;38:975–83. https://doi.org/10.1007/s10439-010-9924-6.10.1007/s10439-010-9924-6 ↗
59. Swedberg AM, Reese SP, Maas SA, Ellis BJ, Weiss JA. Continuum description of the Poisson׳s ratio of ligament and tendon under finite deformation. J Biomech. 2014;47:3201–9. https://doi.org/10.1016/j.jbiomech.2014.05.011.10.1016/j.jbiomech.2014.05.011 ↗