Seismic behavior of full-scale RC columns jacketed by modified multi-spiral stirrups
Source abstract
Abstract
The purpose of this study was to investigate the seismic behavior of RC columns jacketed with a large welded octagonal stirrup at the center and four small spiral stirrups at the corners. Six full-scale RC columns jacketed with the modified multi-spiral stirrups were tested under lateral cyclic load. The effects of axial compression ratio of existing column, shear span ratio and stirrups volumetric ratio in jacket on the seismic behavior of jacketed columns were analyzed. The specimens exhibited excellent deformability and the ultimate drift ratios ranged from 0.046 to 0.063, 2.30–3.15 times as much as specified limit (0.02) of rare earthquake. Additionally, the finite element extended parameter analysis was supplemented after the finite element model verified by the experiment. Finally, an empirical formula for predicting the ductility factor was proposed and exhibited good correlations with the available data of concrete jacketed columns.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Seismic Performance and Analysis · Structural Load-Bearing Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. Murugan K, Sengupta AK. Seismic performance of strengthened reinforced concrete columns. Structures. 2020;27:487–505.10.1016/j.istruc.2020.05.059 ↗
2. Altun F. An experimental study of the jacketed reinforced-concrete beams under bending. Constr Build Mater. 2004;18(8):611–8.10.1016/j.conbuildmat.2004.04.005 ↗
3. Hwang YH, Yang KH, Mun JH, Kwon SJ. Axial performance of RC columns strengthened with different jacketing methods. Eng Struct. 2020;206: 110179.10.1016/j.engstruct.2020.110179 ↗
4. Habib A, Yildirim U, Eren O. Column repair and strengthening using RC jacketing: a brief state-of-the-art review. Innov Infrastruct Sol. 2020;5(3):75.10.1007/s41062-020-00329-4 ↗
5. Thermou GE, Papanikolaou VK, Kappos AJ. Flexural behavior of reinforced concrete jacketed columns under reversed cyclic loading. Eng Struct. 2014;76:270–82.10.1016/j.engstruct.2014.07.013 ↗
6. Fatih A. An experimental study of the jacketed reinforced-concrete beams under bending. Constr Build Mater. 2004;18(8):611–8.10.1016/j.conbuildmat.2004.04.005 ↗
7. Zhao H.Q. Research on reinforcement concretes component’s dynamic performance by the method of enlarging sections. Xi’an: Xi’an University of Science and Technology. 2008.
8. Vandoros KG, Dritsos SE. Concrete jacket construction detail effectiveness when strengthening RC columns. Constr Build Mater. 2008;22(3):264–76.10.1016/j.conbuildmat.2006.08.019 ↗
9. Minafò G. A practical approach for the strength evaluation of RC columns reinforced with RC jackets. Eng Struct. 2015;85:162–9.10.1016/j.engstruct.2014.12.025 ↗
10. Campione M, Fossetti M, Giacchino C, Minafò G. RC columns externally strengthened with RC jackets. Mater Struct. 2014;47:1715–28.10.1617/s11527-013-0146-x ↗
11. Ministry of Housing and Urban-rural Development of the People’s Republic of China. Code for design of strengthening concrete structures, GB/T 50367–2013. China Building Industry Press. 2013.
12. Zhang ZM. The compressive bearing capacity of normal section of RC short column reinforced by section-increased method considering secondary loading. Fuzhou: Fuzhou University; 2016.
13. Júlio ES, Branco F, Silva VD. Structural rehabilitation of columns with reinforced concrete jacketing. Prog Struct Mat Eng. 2010;5:29–37.10.1002/pse.140 ↗
14. Yin SYL, Wang JC, Wang PH. Development of multi-spiral confinements in rectangular columns for construction automation. J Chin Inst Eng. 2012;35(3):309–20.10.1080/02533839.2012.655528 ↗
15. Tang Q, Li Y, Lu XZ, Yan WM. Study on axal compression capacity of multi-spiral hoops confined concrete columns. Eng Mech. 2018;35:166–71.
16. Júlio ES, Branco F, Silva VD. Concrete-to-concrete bond strength. Influence of the roughness of the substrate surface. Constr Build Mater. 2004;18(9):675–81.10.1016/j.conbuildmat.2004.04.023 ↗
17. Júlio ES, Branco F, Silva VD. Reinforcing concrete jacketing-interface influence on monotonic loading response. ACI Struct J. 2005;102(2):252–7.
18. Yang KH, Hwang YH, Mun JH. Seismic behavior of RC jacketed columns under different axial loads. Mag Concr Res. 2020;6:1–29.
19. Yang KH, Hwang YH, Kwon SJ, Mun JH. Flexural behavior of columns strengthened using reinforced concrete jacket with seismic details. ACI Struct J. 2020;117(5):121–32.
20. Xu S, Wu C, Liu Z. Experimental investigation of seismic behavior of ultra-high performance steel fiber reinforced concrete columns. Eng Struct. 2017;152:129–48.10.1016/j.engstruct.2017.09.007 ↗
21. Yi WJ, Zhou Y, Liu Y. Experimental investigation of circular reinforced concrete columns under different loading histories. J Earthquake Eng. 2015;20(3–4):654–75.
22. Jin L, Zhang S, Li D. A combined experimental and numerical analysis on the seismic behavior of short reinforced concrete columns with different structural sizes and axial compression ratios. Int J Damage Mech. 2018;2:1416–47.10.1177/1056789517735679 ↗
23. Ministry of Housing and Urban-rural Development of the people’s Republic of China. Code for seismic design of buildings, GB/T 50011–2010. China Building Industry Press. 2010.
24. Ministry of Housing and Urban-rural Development of the people’s Republic of China. Code for design of concrete structures, GB/T 50010–2010. China Building Industry Press. 2010.
25. ACI Committee 318. Building code requirements for structural concrete (ACI 318–19) and commentary. American Concrete Institute, Farmington Hills; 2019.
26. Ministry of Housing and Urban-rural Development of the people’s Republic of China. Specification for seismic test of buildings, JGJ/T 101–2015. China Building Industry Press. 2015.
27. Ministry of Housing and Urban-rural Development of the people’s Republic of China. Technical specification for post-installed fastenings in concrete structures. JGJ/T 145–2013. China Building Industry Press. 2013.
28. Hou C, Zheng W, Li S. Experimental investigation of full-scale concrete columns confined by high-strength transverse reinforcement subjected to lateral cyclic loading. Arch Civ Mech Eng. 2020;20(4):1–18.10.1007/s43452-020-00126-x ↗
29. Park R. Evaluation of ductility of structures and structural assemblages from laboratory testing. Bulletin of the New Zealand National Society for Earthquake Engineering. 1989.10.5459/bnzsee.22.3.155-166 ↗
30. Wang PH, Chang KC, Yin YL, et al. Simplified finite-element analysis method for axial compression behavior of rectangular concrete columns with interlocking multi-spiral reinforcements. J Struct Eng. 2020;146(1):40.10.1061/(ASCE)ST.1943-541X.0002489 ↗
31. Papanikolaou VK, Kappos AJ. Numerical study of confinement effectiveness in solid and hollow reinforced concrete bridge piers: Methodology. Comput Struct. 2009;87(21–22):1427–39.10.1016/j.compstruc.2009.05.004 ↗
32. Yu T, Teng JG, Wong YL, et al. Finite element modeling of confined concrete-I: Drucker-Prager type plasticity model. Eng Struct. 2010;32(3):665–79.10.1016/j.engstruct.2009.11.014 ↗
33. Teng JG, Xiao QG, Yu T, et al. Three-dimensional finite element analysis of reinforced concrete columns with FRP and/or steel confinement. Eng Struct. 2015;97(15):15–28.10.1016/j.engstruct.2015.03.030 ↗
34. Lubliner J, Oliver J, Oller S, et al. A plastic-damage model for concrete. Int J Solids Struct. 1989;25(3):299–326.10.1016/0020-7683(89)90050-4 ↗
35. Wang XF. Study on seismic behavior of concrete frame columns with high-yield-strength rebars. PhD dissertation, China Academy of Building Research, China, 2013, pp. 56–61.
36. Watson S, Zahn FA. Confining reinforcement for concrete columns. J Struct Eng. 1994;120(6):1798–824.10.1061/(ASCE)0733-9445(1994)120:6(1798) ↗