Resistance and Stability of A New Method for Bonding Biological Materials Using Sutures and Biological Adhesives
Source abstract
Abstract
The valve leaflets of cardiac bioprostheses are secured and shaped by sutures which, given their high degree of resistance and poor elasticity, have been implicated in the generation of stresses within the leaflets, contributing to the failure of the bioprostheses. Bioadhesives are bonding materials that have begun to be utilized in surgery, although there is a lack of experience in their use with inert tissues or bioprostheses. Tensile testing is performed until rupture in samples of calf pericardium, a biomaterial employed in the manufacture of bioprosthetic heart valve leaflets. One hundred and thirty-two trials are carried out in three types of samples: intact or control tissue ( n = 12); samples transected and glued in an overlapping manner with a cyanoacrylate ( n = 60); and samples transected, sewn with a commercially available suture material and reinforced at the suture holes with the same cyanoacrylate ( n = 60). Seven days after their preparation, 12 samples from each group, including the controls, are subjected to tensile testing until rupture and the findings are compared. In the stability study, groups of 12 each of the remaining 48 glued and 48 sutured and glued samples underwent tensile testing until rupture on days 30, 60, 90, and 120, after their preparation. The results show that bonding with the adhesive provided a resistance ranging between 1.04 and 1.87 kg, probably insufficient for use in valve leaflets, but also afforded a high degree of elasticity. After 120 days, both the glued and the sutured and glued series show excellent elastic behavior, with no rigidity or hardening of the pericardium. These samples present reversible elongation, or strain, when they surpass their elastic limit at rupture. This finding may be due to a load concentration that is damaging to the pericardium, to the behavior of the tissue as an amorphous material, or perhaps to both circumstances. These results need to be confirmed in future studies as they may be of value in the design and manufacture of cardiac bioprostheses.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Surgical Sutures and Adhesives · Cardiac Valve Diseases and Treatments · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Servicio de Cirugía Experimental, Clínica Puerta de Hierro, San Martín de Porres 4, 28035 Madrid, España
Departamento de Mecánica Estructural y Resistencia de Materiales, Escuela Técnica Superior de Ingenieros Industriales, José Gutiérrez Abascal 2, 28006 Madrid, España
Servicio de Bioestadística, Clínica Puerta de Hierro, San Martín de Porres 4, 28035 Madrid, España
Servicio de Cirugía Cardiovascular, Clínica Puerta de Hierro, San Martín de Porres 4, 28035 Madrid, España
References (33)
Show source-provided references
1. 10.1016/S0142-9612(00)00260-X10.1016/S0142-9612(00)00260-X ↗
2. 10.1016/0142-9612(94)90078-710.1016/0142-9612(94)90078-7 ↗
3. 10.1016/S0003-4975(95)00390-810.1016/S0003-4975(95)00390-8 ↗
4. 10.1016/S1054-8807(97)00040-910.1016/S1054-8807(97)00040-9 ↗
5. 10.1016/S0022-5223(19)35503-510.1016/S0022-5223(19)35503-5 ↗
6. García Páez, J.M., Carrera, A., Jorge Herrero, E., Millán, I., Navidad, R., Candela, I., García Sestafe, J.V. and Castillo-Olivares, J.L. (1994). Effect of Suture on the Durability of Bovine Pericardium Used in Cardiac Bioprostheses , Biomaterials, 5: 172–176 .10.1016/0142-9612(94)90063-9 ↗
7. Hariza, F., Papouin, G., Barratt-Boyes, B., Christie, G. and Whitlock, R.(1996). Tear in Bioprosthetic Heart Valve Leaflets without Calcific Degeneration , J. Heart Valve Dis., 5: 35–39 .
8. Gonsalbez, J., Cofiño, J., Llosa, J., Naya, J. and Valle, J. (1996). The Use of Biological Glue (CGR) in the Treatment of Left Ventricular Ruptures , Scand. J. Thorac. Cardiovasc. Surg., Suppl. 44-44 .
9. 10.1016/S0003-4975(00)01250-910.1016/S0003-4975(00)01250-9 ↗
10. 10.1001/archfaci.1.4.29210.1001/archfaci.1.4.292 ↗
11. 10.1056/NEJM19960808335060710.1056/NEJM199608083350607 ↗
12. 10.1002/(SICI)1097-4636(199802)39:2<207::AID-JBM6>3.0.CO;2-T10.1002/(SICI)1097-4636(199802)39:2<207::AID-JBM6>3.0.CO;2-T ↗
13. 10.1016/0003-4975(95)98959-X10.1016/0003-4975(95)98959-X ↗
14. Glower, D.D., White, W.D., Hatton, A.C., Smith, L.R., Young, W.G., Wolfe, W.G. and Lowe, J.E. (1994). Determinants of Reoperation after 960 Valve Replacements with Carpentier-Edwards Prostheses , J. Cardiovasc. Surg., 107: 381–393 .10.1016/S0022-5223(94)70083-4 ↗
15. 10.1002/(SICI)1097-4636(199802)39:2<215::AID-JBM7>3.0.CO;2-S10.1002/(SICI)1097-4636(199802)39:2<215::AID-JBM7>3.0.CO;2-S ↗
16. Braile, D.M., Soares, M.J., Souza, D.R., Ramirez, D.A., Suzigan, S. and Godoy, M.F. (1998). Mapping of Bovine Pericardium: Physical and Histopathologic Test , J. Heart Valve Dis., 7: 202–206 .
17. Levy, R.J. (1994). Glutaraldehyde and the Calcification Mechanism of Bioprosthetic Heart Valves , J. Heart Valve Dis., 3: 101–103 .
18. 10.1016/0142-9612(91)90117-S10.1016/0142-9612(91)90117-S ↗
19. 10.1002/(SICI)1097-4636(19980315)39:4<568::AID-JBM10>3.0.CO;2-310.1002/(SICI)1097-4636(19980315)39:4<568::AID-JBM10>3.0.CO;2-3 ↗
20. 10.1016/0142-9612(96)87647-210.1016/0142-9612(96)87647-2 ↗
21. Carrera, A., García Páez, J.M., García Sestafe, J.V., Jorge, E., Navidad, R., Cordon, A. and Castillo-Olivares, J.L. (1998). Analysis of Shearing Stress in the Limited Durability of Bovine Pericardium Used as a Biomaterial , J. Mater. Sci.: Mater. Med., 9: 77–81 .
22. Sacks, M., Chuong, C.J. and More, R. (1994). Collagen Fiber Architecture of Bovine Pericardium , A.S.A.I.O. J., 40: M632–M637 .10.1097/00002480-199407000-00075 ↗
23. 10.1016/S0022-5223(97)70327-110.1016/S0022-5223(97)70327-1 ↗
24. 10.1002/(SICI)1097-4636(199904)45:1<20::AID-JBM3>3.0.CO;2-610.1002/(SICI)1097-4636(199904)45:1<20::AID-JBM3>3.0.CO;2-6 ↗
25. 10.1002/(SICI)1097-4636(199601)30:1<47::AID-JBM7>3.0.CO;2-R10.1002/(SICI)1097-4636(199601)30:1<47::AID-JBM7>3.0.CO;2-R ↗
26. Gould, P.L., Cataloguin, A., Dhatt, P.S., Chattopadhyay, A. and Clark, R.(1973). Stress Analysis of the Human Aortic Valve, In: Computer and Structures, pp. 377–384, Pergamon Press, London .10.1016/0045-7949(73)90024-2 ↗
27. 10.1002/jbm.82028010710.1002/jbm.820280107 ↗
28. Timoshenko, S. (1970). Resistencia de Materiales (Spanish translation), Part 1, Chapter I: pp. 1–6, Chapter X: pp. 274-285, Part 2, Chapter VII: pp. 316-323, Espasa Calpe, Madrid .
29. 10.1002/jbm.1029310.1002/jbm.10293 ↗
30. Hernando Grande, A. (1987). Nuevos Materiales: Los Vidrios Metálicos, Sólidos Amorfos, 13–14, Eudema (Ediciones de la Universidad Complutense de Madrid), Madrid.
31. 10.1002/jbm.82024100710.1002/jbm.820241007 ↗
32. 10.1016/0142-9612(94)90199-610.1016/0142-9612(94)90199-6 ↗
33. 10.1016/1010-7940(93)90264-C10.1016/1010-7940(93)90264-C ↗