Methodology of the quantitative assessment of the moisture content of saline brick walls in historic buildings using machine learning
Source abstract
Abstract
Abstract Conducting moisture tests of brick walls in buildings under conservation protection is associated with many difficulties that result from the inability to freely interfere with historic tissue. The current paradigm of conducting such research, which assumes the use of just one non-destructive method, has many limitations that affect the accuracy of obtained results. Up-to-date research concerning an alternative non-invasive method, which allows reliable test results to be obtained in the case of the quantitative assessment of the moisture content of saline brick walls in historic buildings, has shown that it is possible to reliably assess such a moisture content using machine learning and two complementary non-destructive methods. In the article, the original methodology of such a quantitative assessment is described and presented in the form of block diagrams. The methodology consists of two stages. The first stage includes carrying out experimental and archival research in selected historical buildings to create a data set. The second stage involves generating a machine learning model for assessing the moisture content based on algorithms and the data collected in the first stage. The article is illustrated with an example of the application of the developed methodology to assess the moisture content of the brick walls of the Golden Gate building in Gdańsk. The presented example shows the reliability and practical usefulness of the developed methodology.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Conservation Techniques and Studies · Building materials and conservation · Geophysical Methods and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. Trochonowicz M, Szostak B, Lisiecki D. Comparative analysis of chemical moisture tests in relation to gravimetric tests of selected building materials (in Polish) [PDF file]. Budownictwo i Architektura 2016;15:163–171. Accessed 30 Sep 2022; https://yadda.icm.edu.pl/baztech/element/bwmeta1.element.baztech-1057ac67-7150-45d6-b5cc-889a37851f86?q=bwmeta1.element.baztech-125dd901-97ba-47fa-b516-eba017243ed1;15&qt=CHILDREN-STATELESS
2. Hussain A, Akhtar S. Review of non-destructive tests for evaluation of historic masonry and concrete structures. Arab J Sci Eng. 2017. https://doi.org/10.1007/s13369-017-2437-y.10.1007/s13369-017-2437-y ↗
3. Sandrolini F, Franzoni E. An operative protocol for reliable measurements of moisture in porous materials of ancient buildings. Build Environ. 2006. https://doi.org/10.1016/j.buildenv.2005.05.023.10.1016/j.buildenv.2005.05.023 ↗
4. Trochonowicz M. Moisture in buildings. Problems of humidity tests (in Polish) [PDF file]. Budownictwo i Architektura 2010;7:131–144. Accessed 30 Sep 2022; http://yadda.icm.edu.pl/baztech/element/bwmeta1.element.baztech-article-BPL2-0019-002310.35784/bud-arch.2274 ↗
5. Martínez-Garrido MI, Fort R, Gómez-Heras M, Valles-Iriso J, Varas-Muriel MJ. A comprehensive study for moisture control in cultural heritage using non-destructive techniques. J Appl Geophys. 2018. https://doi.org/10.1016/j.jappgeo.2018.03.008.10.1016/j.jappgeo.2018.03.008 ↗
6. Válek J, Kruschwitz S, Wöstmann J, Kind T, Valach J, Köpp Ch, Lesák J. Nondestructive investigation of wet building material: multimethodical approach. J Perform Constr Facil. 2010. https://doi.org/10.1061/ASCECF.1943-5509.0000056.10.1061/ASCECF.1943-5509.0000056 ↗
7. Binda L, Cardani G, Zanzi L. Nondestructive testing evaluation of drying process in flooded full-scale masonry walls. J Perform Constr Facil. 2010. https://doi.org/10.1061/%28ASCE%29CF.1943-5509.0000097.10.1061/%28ASCE%29CF.1943-5509.0000097 ↗
8. Adamowski J, Hoła J, Matkowski Z. Probleme und Losungen beim Feuchtigkeitsschutz des Mauerwerks von Baudenkmalern am Beispiel zweier grosser Barockbauten in Wroclaw. Bautechnik. 2005. https://doi.org/10.1002/bate.200590148.10.1002/bate.200590148 ↗
9. Rokiel M. Waterproofing in construction (in Polish), Warszawa: Grupa MEDIUM; 2006; ISBN: 978–83–64094–63–7
10. Rosina E, Ludwig N, Rosi L. Optimal environmental conditions to detect moisture in ancient buildings: case studies in Northern Italy. In: SPIE Conference Proceedings, Thermosense Doi: https://doi.org/10.1117/12.30472810.1117/12.304728 ↗
11. Hoła A, Matkowski Z, Hoła J. In-situ moisture assessment in external walls of historic building using non-destructive methods. Procedia Engineering. 2017. https://doi.org/10.1016/j.proeng.2017.02.041.10.1016/j.proeng.2017.02.041 ↗
12. Freimanis R, Vaiskunaite R, Bezrucko T, Blumberga A. In-situ moisture assessment in external walls of historic building using non-destructive methods. Environmen Clim Technol. 2019. https://doi.org/10.2478/rtuect-2019-0009.10.2478/rtuect-2019-0009 ↗
13. Hoła A. Methodology for the in situ testing of the moisture content of brick walls: an example of application. Archiv Civil Mech Eng. 2020. https://doi.org/10.1007/s43452-020-00120-3.10.1007/s43452-020-00120-3 ↗
14. Hoła A. Measuring of the moisture content in brick walls of historical buildings the overview of methods. IOP Conf Ser. 2017. https://doi.org/10.1088/1757-899X/251/1/012067.10.1088/1757-899X/251/1/012067 ↗
15. Pala A, Hoła J. Influence of burnt clay brick salinity on moisture content evaluated by non-destructive electric methods. Archiv Civil Mech Eng. 2016. https://doi.org/10.1016/j.acme.2015.08.001.10.1016/j.acme.2015.08.001 ↗
16. Matkowski Z. Problems connected with methodology of dampness testing applied to brick walls in historical monuments (in Polish) [PDF file]. Materiały budowlane 2014;3:14–16. Accessed March 25, 2023; https://www.materialybudowlane.info.pl/images/2014/03/s14-16.pdf10.1007/s15005-014-1101-2 ↗
17. Valero LR, Sasso VF, Vicioso EP. In situ assessment of superficial moisture condition in façades of historic building using non-destructive techniques. Case Stud Construct Mater. 2019. https://doi.org/10.1016/j.cscm.2019.e00228.10.1016/j.cscm.2019.e00228 ↗
18. Balík L, Kudrnáčová L, Pavlík Z, Černý R. Application of infrared thermography in complex moisture inspection of the Schebek Palace. AIP Conf Proc. 2017. https://doi.org/10.1063/1.4994482.10.1063/1.4994482 ↗
19. Muradov M, Kot P, Markiewicz J, Łapiński S, Tobiasz A, Onisk K, Shaw A, Hashim K, Zawieska D, Mohi-Ud-Din G. Non-destructive system for in-wall moisture assessment of cultural heritage buildings. Measurement. 2022. https://doi.org/10.1016/j.measurement.2022.111930.10.1016/j.measurement.2022.111930 ↗
20. Rymarczyk T, Kłosowski G, Kozłowski E. A non-destructive system based on electrical tomography and machine learning to analyze the moisture of buildings. Sensors. 2018. https://doi.org/10.3390/s18072285.10.3390/s18072285 ↗
21. Rymarczyk T, Kłosowski G, Hoła A, Hoła J, Sikora J, Tchórzewski P, Skowron Ł. Historical buildings dampness analysis using electrical tomography and machine learning algorithms. Energies. 2021. https://doi.org/10.3390/en14051307.10.3390/en14051307 ↗
22. Hoła A, Sadowski Ł. A method of the neural identification of the moisture content in brick walls of historic buildings on the basis of non-destructive tests. Autom Constr. 2019. https://doi.org/10.1016/j.autcon.2019.102850.10.1016/j.autcon.2019.102850 ↗
23. Hoła A, Czarnecki S. Brick wall moisture evaluation in historic buildings using neural networks. Autom Constr. 2022. https://doi.org/10.1016/j.autcon.2022.104429.10.1016/j.autcon.2022.104429 ↗
24. Hoła A, Czarnecki S. Random forest algorithm and support vector machine for nondestructive assessment of mass moisture content of brick walls in historic buildings. Autom Constr. 2023. https://doi.org/10.1016/j.autcon.2023.104793.10.1016/j.autcon.2023.104793 ↗
25. Espinosa RM, Franke L, Deckelmann G. Phase changes of salts in porous materials. Crystallization, hydration and deliquescence. Construct Build Mater. 2008. https://doi.org/10.1016/j.conbuildmat.2007.05.005.10.1016/j.conbuildmat.2007.05.005 ↗
26. Raimondo M, Dondi M, Guardini G, Mazzanti F. Predicting the initial rate of water absorption in clay brick. Constr Build Mater. 2009. https://doi.org/10.1016/j.conbuildmat.2009.01.009.10.1016/j.conbuildmat.2009.01.009 ↗
27. Kubik J. Moisture flow in building materials (in Polish). Opole: Oficyna Wydawnicza Politechniki Opolskiej; 2000; ISBN: 83–88492–56-X
28. Alsabry A. Dynamics of capillary rising in building walls (in Polish) [PDF file]. Przegląd Budowlany 2010;9:46–48. Accessed 30 Sep 2022; https://www.przegladbudowlany.pl/2010/09/2010-09-PB-46-48_Alsabry.pdf
29. Monczyński B. Diagnosis of damp wall structures (in Polish). Izolacje 2019;1. Accessed 18 Sep 2022; https://www.izolacje.com.pl/artykul/osuszanie-budynkow/188809,diagnostyka-zawilgoconych-konstrukcji-murowych
30. Sun H, Burton HV, Huang H. Machine learning applications for building structural design and performance assessment: State-of-the-art review. J Building Eng. 2021. https://doi.org/10.1016/j.jobe.2020.101816.10.1016/j.jobe.2020.101816 ↗
31. ApostolopoulouM ArmaghaniDJ, BakolasA DouvikaMG, MoropoulouA AsterisPG. Compressivestrengthofnaturalhydrauliclimemortarsusingsoftcomputingtechniques. Procedia StructuralIntegrity. 2019. https://doi.org/10.1016/j.prostr.2019.08.122.10.1016/j.prostr.2019.08.122 ↗
32. Asteris PG, Douvika MG, Karamani CA, Skentou AD, Chlichlia K, Cavaleri L, Daras T, Armaghani DJ, Zaoutis TE. A novel heuristic algorithm for the modeling and risk assessment of the COVID19 pandemic phenomenon. Comput Model Eng Sci. 2020. https://doi.org/10.32604/cmes.2020.013280.10.32604/cmes.2020.013280 ↗
33. Armaghani DJ, Asteris PG. A comparative study of ANN and ANFIS models for the prediction of cement-based mortar materials compressive strength. Neural Comput Appl. 2020. https://doi.org/10.1007/s00521-020-05244-4.10.1007/s00521-020-05244-4 ↗