Osteoblast viability on hydroxyapatite with well-adjusted submicron and micron surface roughness as monitored by the proliferation reagent WST-1
Source abstract
Abstract
The impact of the cell surface roughness on titanium alloys used for biomedical implants has been extensively studied, whereas the dependency of human osteoblast viability on hydroxyapatite (HA) submicron and micron surface roughness has hitherto not yet been investigated in detail. Therefore, we investigate in this study the effect of HA substrates with different well-adjusted surface roughness on human osteoblast proliferation using the standard colorimetric reagent WST-1. By grinding, we obtained HA surfaces with six levels of well-defined surface roughness ranging from Sa = 3.36 µm down to 0.13 µm, resulting in hydrophilic contact angles from 11° to 27°. Energy dispersive X-ray spectroscopy, X-ray diffraction, and X-ray fluorescence measurements confirmed that neither grinding paper residues nor changes of the crystal structure were introduced to the HA substrates by the grinding process. By applying this simple surface treatment, we were able to isolate other effects from surface chemistry, crystal structure, and relative density. The changes of the osteoblast proliferation (WST-1 assay) on these different roughened HA surfaces after 7 days were found to be insignificant ( p > 0.05), evaluated by one-way analysis of variance and Tuckey’s Multiple Comparison Method. The results of this study show that all roughened HA surfaces, regardless of the microtopography, are biocompatible and allow osteoblast attachment, proliferation, and collagen type I production. The comparison with surface roughness used for standard Ti-based implants yielded that for HA no finishing process is necessary to ensure a sound human osteoblast cell proliferation in vitro.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Advanced Ceramics, University of Bremen, Bremen, Germany
References (38)
Show source-provided references
1. Kim Y, Yamashita J, Shotwell JL, Chong K-H, Wang H-L. The comparison of provisional luting agents and abutment surface roughness on the retention of provisional implant-supported crowns. J Prosthetic Dentistry 2006; 95: 450–455.
2. Mustafa K, Odén A, Wennerberg A, Hultenby K, Arvidson K. The influence of surface topography of ceramic abutments on the attachment and proliferation of human oral fibroblasts. Biomaterials 2005; 26: 373–381.
3. Lemons JE. Ceramics: Past, present, and future. Bone 1996; 19: 121–128.
4. 10.1007/978-3-642-58407-710.1007/978-3-642-58407-7 ↗
5. Dorozhkin SV. Calcium orthophosphate-based biocomposites and hybrid biomaterials. J Mater Sci 2009; 44: 2343–2387.
6. Wang H, Gerbaudo VH, Hobbs LW, Spector M. Quantitation of osteoblast-like cell mineralization on tissue culture polystyrene and Ti-6Al-4V alloy disks by Tc-99m-MDP labeling and imaging in vitro. Bone 2005; 36: 84–92.
7. Boyan BD, Hummert TW, Dean DD, Schwartz Z. Role of material surfaces in regulating bone and cartilage cell response. Biomaterials 1996; 17: 137–146.
8. Mangano C, De Rosa A, Desiderio V, . The osteoblastic differentiation of dental pulp stem cells and bone formation on different titanium surface textures. Biomaterials 2010; 31: 3543–3551.
9. 10.1163/156856298X0041510.1163/156856298X00415 ↗
10. 10.1177/1045441196007004030110.1177/10454411960070040301 ↗
11. Thomas KA Kay JF Cook SD and Jarcho M. The effect of surface macrotexture and hydroxylapatite coating on the mechanical strengths and histologic profiles of titanium implant materials. J Biomed Mater Res 1987; 21: 1097–4636.10.1002/jbm.820211205 ↗
12. Bowers KT Keller JC Randolph BA Wick DG and Michaels CM. Optimization of surface micromorphology for enhanced osteoblast responses in vitro. Inter J Oral Maxill Implants 1992 7: 302–310.
13. Boyan BD, Bonewald LF, Paschalis EP, . Osteoblast-Mediated Mineral Deposition in Culture is Dependent on Surface Microtopography. Calcified Tissue Int 2002; 71: 519–529.
14. Keller JC, Schneider GB, Stanford CM, Kellogg B. Effects of Implant Microtopography on Osteoblast Cell Attachment. Implant Dentistry 2003; 12: 175–181.
15. Kunzler TP, Drobek T, Schuler M, Spencer ND. Systematic study of osteoblast and fibroblast response to roughness by means of surface-morphology gradients. Biomaterials 2007; 28: 2175–2182.
16. Schneider GB, Perinpanayagam H, Clegg M, . Implant surface roughness affects osteoblast gene expression. J Dent Res 2003; 82: 372–376.
17. Deligianni DD, Katsala ND, Koutsoukos PG, Missirlis YF. Effect of surface roughness of hydroxyapatite on human bone marrow cell adhesion, proliferation, differentiation and detachment strength. Biomaterials 2000; 22: 87–96.
18. Ball MD Downes S Scotchford CA et al. Osteoblast growth on titanium foils coated with hydroxyapatite by pulsed laser ablation Biomaterials 2001 22: 337–347.10.1016/S0142-9612(00)00189-7 ↗
19. Hayashi K, Inadome T, Tsumura H, Nakashima Y, Sugioka Y. Effect of surface roughness of hydroxyapatite—coated titanium on the bone-implant interface shear strength. Biomaterials 1994; 15: 1187–1191.
20. CD ISO25178-6. Geometrical product specification (GPS)-Surface texture: areal - Part 6: classification of methods for measuring surface texture International Organization for Standardization, 2007.
21. Wennerberg A, Albrektsson T. Effects of titanium surface topography on bone integration: a systematic review. Clinical Oral Implants Research 2009; 20: 172–184.
22. Anselme K. Osteoblast adhesion on biomaterials. Biomaterials 2000; 21: 667–681.
23. Schakenraad JM, Busscher HJ, Wildevuur CRH, Arends J. The influence of substratum surface free energy on growth and spreading of human fibroblasts in the presence and absence of serum proteins. J Biomed Mater Res 1986; 20: 773–784.
24. Rosa AL, Beloti MM, van Noort R. Osteoblastic differentiation of cultured rat bone marrow cells on hydroxyapatite with different surface topography. Dent Mater 2003; 19: 768–772.
25. Detsch R, Uhl F, Deisinger U, Ziegler G. 3D-Cultivation of bone marrow stromal cells on hydroxyapatite scaffolds fabricated by dispense-plotting and negative mould technique. J Mater Sci Mater M 2008; 19: 1491–1496.
26. Huang J, Jayasinghe S, Best SM, . Novel deposition of nano-sized silicon substituted hydroxyapatite by electrostatic spraying. J Mater Sci Mater M 2005; 16: 1137–1142.
27. Li X Huang J Ahmad Z and Edirisinghe M. Electrohydro-dynamic coating of metal with nano-sized hydroxyapatite Bio-Medical Materials and Engineering 2007 17: 335–346.
28. Lim JY, Hansen JC, Siedlecki CA, . Osteoblast Adhesion on Poly(l-lactic Acid)/Polystyrene Demixed Thin Film Blends: Effect of Nanotopography, Surface Chemistry, and Wettability. Biomacromolecules 2005; 6: 3319–3327.
29. Matsuda N, Yokoyama K, Takeshita S, Watanabe M. Role of epidermal growth factor and its receptor in mechanical stress-induced differentiation of human periodontal ligament cells in vitro. Arch Oral Biol 1998; 43: 987–997.
30. Thian ES, Ahmad Z, Huang J, . The role of electrosprayed apatite nanocrystals in guiding osteoblast behaviour. Biomaterials 2008; 29: 1833–1843.
31. Thian ES, Huang J, Best SM, . The response of osteoblasts to nanocrystalline silicon-substituted hydroxyapatite thin films. Biomaterials 2006; 27: 2692–2698.
32. Yamakura K, Watanabe H, Abe S, Yanagisawa T. Ultrastructural Changes in Calvarial Osteoblast Cytoskeleton after Prostaglandin E2 Administration in Rats. Anat Histol Embryol 2001; 30: 301–307.
33. Zhu X Chen J Scheideler L Altebaeumer T Geis-Gerstorfer J and Kern D. Cellular Reactions of Osteoblasts to Micron- and Submicron-Scale Porous Structures of Titanium Surfaces. Cells Tissues Organs 2004; 178: 13–22.10.1159/000081089 ↗
34. Zhu X Chen J Scheideler L Reichl R and Geis-Gerstorfer J. Effects of topography and composition of titanium surface oxides on osteoblast responses. Biomaterials 2004; 25: 4087–4103.10.1016/j.biomaterials.2003.11.011 ↗
35. Fackler OT, Grosse R. Cell motility through plasma membrane blebbing. J Cell Biol 2008; 181: 879–884.
36. Hagmann J, Burger MM, Dagan D. Regulation of plasma membrane blebbing by the cytoskeleton. J Cell Biochem 1999; 73: 488–499.
37. Panupinthu N, Zhao L, Possmayer F, Ke HZ, Sims SM, Dixon SJ. P2X7 nucleotide receptors mediate blebbing in osteoblasts through a pathway involving lysophosphatidic acid. J Biol Chem 2007; 282: 3403–3412.
38. Engel E, Valle SD, Aparicio C, Altanakov G, Asin L, Planell JA, . Discerning the role of topography and ion exchange in cell response of bioactive tissue engineering Scaffolds. Tissue Eng: Part A 2008; 14: 1341–1351.