Introduction of Surface Functional Groups onto Biomaterials by Glow Discharges
Source abstract
Abstract
An attempt was made to graft the monomer HEMA to the polymer surface by "Glow discharge" technique. Experiments were carried out for different surfaces varying the exposure times of samples to HEMA and also as a function of glow discharge time. It was found that as the percentage of grafting increases the hydrophilicity also increases. Contact angle measurements were performed on these substrates, which confirmed the hydrophilic nature of the grafted samples compared to the controls. The role of protein adsorption and their effects to modulate the blood polymer interaction is briefly discussed. When a foreign material comes in contact with blood, the initial event is the adsorption of plasma proteins in parallel with the adhesion of platelets to the material. Albuminated surfaces discourage platelet adhesion while fibrinogen enhances the platelet attachment and thrombosis. Hence a decreased ratio of fibrinogen to albumin on a substrate can be correlated as an indication to its improved blood compatibility. Fibrinogen to albumin ratios of the grafted samples showed a reduction, indicating that albumin adsorption is high; which may make the modified surfaces non-thrombogenic.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Polymer Surface Interaction Studies · Advanced Sensor and Energy Harvesting Materials · Electrospun Nanofibers in Biomedical Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Division of Biosurface Technology Sree Chitra Tirunal Insitute for Medical Sciences and Technology BMT Wing, Poojapura Trivandrum-695012 India
References (30)
Show source-provided references
1. Bruck, S.D. · Sci. · 1977 · 283 · 332
2. Lyman, D.J. · Trans. Am. Soc. Artif. Intern. Organs · 1974 · 20 · 474
3. Lyman, D.J. · Trans. Am. Soc. Artif. Intern. Organs · 1975 · 21 · 49
4. Feigen, J.
5. Lyman, D.J. · Trans. Am. Soc. Artif. Intern. Organs · 1968 · 24 · 250
6. 10.1097/00002480-197301900-0000110.1097/00002480-197301900-00001 ↗
7. Kaelble, D.
8. Sharma, C. · P. J. Sci. Ind. Res. · 1980 · 39 · 453
9. 10.1016/0142-9612(81)90091-010.1016/0142-9612(81)90091-0 ↗
10. 10.1016/0021-9797(81)90245-910.1016/0021-9797(81)90245-9 ↗
11. 10.1016/0021-9797(84)90332-110.1016/0021-9797(84)90332-1 ↗
12. Sharma, C. · Sci. Tech. · 1986 · 2 · 47
13. Lyman, D.J. · Thromb. Diath. Haem. · 1970 · 42 · 109
14. Lee, E.S. · ASAIO J. · 1980 · 31
15. 10.1126/science.142.3597.129710.1126/science.142.3597.1297 ↗
16. 10.1002/polc.507066013210.1002/polc.5070660132 ↗
17. 10.1002/jbm.82008060510.1002/jbm.820080605 ↗
18. Sharma, C.P. · Cellular Polymers · 1984 · 3 · 32510.1177/026248938400300501 ↗
19. 10.1038/185117a010.1038/185117a0 ↗
20. 10.1097/00002480-197201000-0000110.1097/00002480-197201000-00001 ↗
21. Abrahams, R.A. · Soc. Plast. Eng. Tech. Pap. · 1975 · 21 · 570
22. 10.1021/bk-1976-0031.ch00110.1021/bk-1976-0031.ch001 ↗
23. Bruck, S.D. Blood Compatible Synthetic Polymers. Springfield, IL: Charles C. Thomas, pp. 94-96 (1974).
24. 10.1002/jbm.82007050310.1002/jbm.820070503 ↗
25. 10.1002/jbm.82008030910.1002/jbm.820080309 ↗
26. 10.1002/jbm.82007060410.1002/jbm.820070604 ↗
27. 10.1002/jbm.82009050510.1002/jbm.820090505 ↗
28. 10.1002/polc.507066013410.1002/polc.5070660134 ↗
29. Chapiro, A. · J. Chem. Phys. · 1956 · 53 · 895
30. 10.1002/jbm.82006030610.1002/jbm.820060306 ↗